31
MESSAGE MEANING
ACTION REQUIRED
LF
Low Flow
– persistent
problem. Displays after
the fifth occurrence of
the "HL" message
within 24 hours. Heater
shuts down but other
spa functions run
normally.
Heating capacity of the spa
will not reset automatically;
press any button to reset.
dr
Inadequate water,
poor flow, or air
bubbles detected in
the heater. Spa is shut
down for 15 minutes.
Check water level in spa.
Add water if necessary. Be
sure that slide-valves are
open. Make sure the pump is
primed and has power. Press
any button to reset
(automatically reset within 15
minutes). If the problem
persists, contact service.
dy
Inadequate water
detected in heater.
Displays on third
occurrence of "dr"
message. Spa is shut
down.
Check water level in spa.
Add water if necessary. Be
sure that slide-valves are
open. Make sure the pump is
primed and has power. Press
any button to reset.
Pr
When your spa is first
activated, it goes into
Priming mode.
The Priming mode runs for up
to four minutes and then the
spa begins to heat and
maintain the water
temperature in Standard
mode.
- - F
Temperature unknown
After the pump has been
running for two minutes, the
temperature will be
displayed.
- - C
Temperature unknown
After the pump has been
running for two minutes, the
temperature will be
displayed.
Содержание DX 5000
Страница 12: ...10 US Canada 240V Wiring Diagram All wiring is 6 3 plus ground solid copper ...
Страница 15: ...13 European 3 phase Wiring Note 3 phase wiring is not possible with these spas Wire as 1 phase or 2 phase only ...
Страница 16: ...14 120V 20A Wiring Diagram GFCI Plug Test Reset For DX 5000 Domestic models ...
Страница 17: ...15 For DX 5000 European Models For EX 3000 Domestic Models ...
Страница 18: ...16 For LX 4000 and IX 40 Domestic Models For LX 4000 Export Models ...
Страница 25: ...23 ...
Страница 46: ...44 Notes ...
Страница 47: ...45 Notes ...
Страница 50: ...48 Notes ...
Страница 52: ...5701 E Hillsborough Ave Suite 2450 Tampa FL 33610 5428 727 471 1060 www GulfCoastSpas com ...