background image

 

3

6. 

Add  distilled  water  in  each  cell  until  battery  acid  reaches  levels  specified  by  the 

battery manufacturer, if applicable.  Do not overfill.  For all batteries, carefully follow 

the manufacturer’s recharging instructions. 

7. 

Never allow the ring terminals to touch each other. 

8. 

NEVER

 charge a frozen battery. 

9.   

Please be sure the DC system to which the charger is connected is not drawing 

excessive current from the battery for extended periods of time while the charger is 

operating.  This is important to ensure the charger correctly transitions through each 

charging stage to finish with the float voltage level.  If the DC system is drawing 

continuous current while charging, reduced life or damage to the battery may occur. 

 

 

AC Connection and Grounding Precautions 

DANGER 

DO NOT OPERATE THIS CHARGER WITH A TWO BLADED ADAPTER PLUG OR 

EXTENSION CORD.  DOING SO CAN RESULT IN SERIOUS PERSONAL INJURY. 

AFTER  SECURING  THE  BATTERY  CONNECTIONS,  PLUG  THE  AC  LINE  CORD 

INTO AN AVAILABLE AC OUTLET THAT IS PROTECTED BY A GROUND FAULT 

CIRCUIT INTERRUPTER (GFCI) BREAKER.

  

 

CAUTION:

 

To reduce the risk of shock, connect only to a properly grounded outlet. 

NOTE:

  AC Line Cord color coding is EU style.  Line = Brown, Neutral = Blue, Ground = 

Green

 

2. INSTALLING THE CHARGER 

 

Choosing Charging Location 

The charger should have at least eight inches of unobstructed area on all sides of the 

unit for effective cooling.  The case of this charger will become warm during operation. 

Because the charger is convection cooled (airflow over the back of the charger), the 

optimum  mounting  position  for  the  charger  is  vertical.  Mounting  on  its  back  on  a 

horizontal surface may cause the charger to slightly reduce amperage output due to the 

thermal  protection  built  in.  Do  not  install  the  charger  on  carpeted,  upholstered,  or 

varnished surfaces. 

Mounting the Charger

 

1. 

Use  corrosion  resistant  3/16”  dia.  or  #  10  bolts,  backed  by  a  flat  washer,  and 

secured to the mounting surface with a split-ring lock washer. 

2. 

Hold the charger to the mounting surface and mark the holes. 

3. 

Remove the charger and drill the mounting holes. 

4. 

Align the charger and assemble the mounting hardware. Secure. 

 

Содержание Trolling Charger 2607A

Страница 1: ...h recharge your batteries and extend your battery s life in applications where it is stored for long periods of time They are 3 stage electronic completely automatic lightweight silent battery charger...

Страница 2: ...s the eye flood the eye with cold running water for at least ten minutes and get medical attention 5 Never smoke or allow an open flame in the vicinity of the battery 6 Do not drop a metal tool onto t...

Страница 3: ...AVAILABLE AC OUTLET THAT IS PROTECTED BY A GROUND FAULT CIRCUIT INTERRUPTER GFCI BREAKER CAUTION To reduce the risk of shock connect only to a properly grounded outlet NOTE AC Line Cord color coding...

Страница 4: ...details Battery Size Recommendations The recommended maximum battery size per 3 amp bank is 36AH The recommended maximum battery size per 5 amp bank is 60AH The recommended maximum battery size per 6...

Страница 5: ...nings For the 2607A output 1 and output 2 may be connected in parallel for a 12 V 6 amp output Both outputs may also be connected in series for a 24 V output see below 2607A Connections Diagram 2 2607...

Страница 6: ...nnections Model Output Volts Output Amps Banks DC Cable Size Size inches L x W x H Input Volts Input Amps Max 2608A 12 6 1 4 3 5 x 6 4 x 2 25 115VAC 50 60Hz 2 Amps Diagram 3 2608A 6 Amps used with 1 1...

Страница 7: ...Amps Max 2611A 12 24 5 5 2 4 4 4 25 x 7 x 2 42 115VAC 50 60Hz 2 5 Amps Diagram 4 2611A 5 5 Amps used with 2 independent 12V Batteries 2611A Connections For the 2611A Output 1 and output 2 may be conne...

Страница 8: ...8 2611A Connections Diagram 5 2611A used in a 24 V system...

Страница 9: ...6 2610A 5 5 Amps used with 2 12V Batteries 2610A Connections The 2610A can be used on 2 12 volt independent batteries It may NOT be used for a 24 Volt system the outputs may NOT be wired in series The...

Страница 10: ...10 2610A Connections Diagram 7 2610A used in a single battery system LISTED 14 OR 15 AMP FUSE...

Страница 11: ...radually reduces the amount of current Amps it delivers to the battery By doing this the battery is able to absorb the last 10 of charge as quickly as possible without becoming overheated If both ligh...

Страница 12: ...reduces the amount of current Amps it delivers to the battery By doing this the battery is able to absorb the last 10 of charge as quickly as possible without becoming overheated If both lights stay...

Страница 13: ...y reduces the amount of current Amps it delivers to the battery By doing this the battery is able to absorb the last 10 of charge as quickly as possible without becoming overheated If both lights stay...

Страница 14: ...ive or damaged cells 3 Extremely low AC voltage at the battery charger 1 Turn off all DC equipment while charging 2 Load test the batteries and replace if necessary 3 Apply a higher AC voltage source...

Страница 15: ...le protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used...

Страница 16: ...s are not accepted for warranty proof of purchase In the absence of a receipt warranty period will be calculated from date of manufacture printed or stamped on the product There is no other expressed...

Отзывы: