5. MAINTAINING THE CHARGER 

 

Periodically clean both battery terminals with baking soda and tighten all connections.  

No other maintenance on the charger is required. 

 

 
 
6. SPECIFICATIONS 

Model 

Output 

Volts 

Output 

Amps 

Banks  DC Cable 

Size 

Size (inches) 

L x W x H 

Input Volts 

Input 

Amps Max 

2607A 

12/24

 

3/3 

4’/4’ 

3.5 x 6.4 x 2.25 

115VAC 

50/60Hz 

2 Amps 

2608A 

12 

4’ 

3.5 x 6.4 x 2.25 

115VAC 

50/60Hz 

2 Amps 

2610A 

12 

5/5 

N/A 

4.25 x 7 x 2.42 

115VAC 

50/60Hz 

2.5 Amps 

2611A 

12/24 

5/5 

4’/4’ 

4.25 x 7 x 2.42 

115VAC 

50/60Hz 

2.5 Amps 

FCC Class A EMC Notice 

This equipment has been tested and found to comply with the limits for a Class A digital device, 

pursuant to part 15 of the FCC Rules.  These limits are designed to provide reasonable protection 

against harmful interference when the equipment is operated in a commercial environment.  This 

equipment generates, uses and can radiate radio frequency energy and, if not installed and used in 

accordance  with  the  instructions,  may  cause  harmful  interference  to  radio  communications.  

Operation of this equipment in a residential area is likely to case harmful interference in which case 

the user will be required to correct the interference at his own expense. 

If  this  equipment  does  cause  harmful  interference  to  radio  or  television  reception,  which  can  be 

determined  by  turning  this  equipment  off  and  on,  the  user  is  encouraged  to  try  to  correct  the 

interference by one or more of the following measures: 

---Reorient or relocate the receiving antenna. 

---Increase the separation between the equipment and receiver. 

---Connect the equipment into an outlet on a circuit different from that to which the 

    receiver is connected. 

 

 

 

 

 

 

 

Содержание Trolling Charger 2607A

Страница 1: ...h recharge your batteries and extend your battery s life in applications where it is stored for long periods of time They are 3 stage electronic completely automatic lightweight silent battery charger...

Страница 2: ...s the eye flood the eye with cold running water for at least ten minutes and get medical attention 5 Never smoke or allow an open flame in the vicinity of the battery 6 Do not drop a metal tool onto t...

Страница 3: ...AVAILABLE AC OUTLET THAT IS PROTECTED BY A GROUND FAULT CIRCUIT INTERRUPTER GFCI BREAKER CAUTION To reduce the risk of shock connect only to a properly grounded outlet NOTE AC Line Cord color coding...

Страница 4: ...details Battery Size Recommendations The recommended maximum battery size per 3 amp bank is 36AH The recommended maximum battery size per 5 amp bank is 60AH The recommended maximum battery size per 6...

Страница 5: ...nings For the 2607A output 1 and output 2 may be connected in parallel for a 12 V 6 amp output Both outputs may also be connected in series for a 24 V output see below 2607A Connections Diagram 2 2607...

Страница 6: ...nnections Model Output Volts Output Amps Banks DC Cable Size Size inches L x W x H Input Volts Input Amps Max 2608A 12 6 1 4 3 5 x 6 4 x 2 25 115VAC 50 60Hz 2 Amps Diagram 3 2608A 6 Amps used with 1 1...

Страница 7: ...Amps Max 2611A 12 24 5 5 2 4 4 4 25 x 7 x 2 42 115VAC 50 60Hz 2 5 Amps Diagram 4 2611A 5 5 Amps used with 2 independent 12V Batteries 2611A Connections For the 2611A Output 1 and output 2 may be conne...

Страница 8: ...8 2611A Connections Diagram 5 2611A used in a 24 V system...

Страница 9: ...6 2610A 5 5 Amps used with 2 12V Batteries 2610A Connections The 2610A can be used on 2 12 volt independent batteries It may NOT be used for a 24 Volt system the outputs may NOT be wired in series The...

Страница 10: ...10 2610A Connections Diagram 7 2610A used in a single battery system LISTED 14 OR 15 AMP FUSE...

Страница 11: ...radually reduces the amount of current Amps it delivers to the battery By doing this the battery is able to absorb the last 10 of charge as quickly as possible without becoming overheated If both ligh...

Страница 12: ...reduces the amount of current Amps it delivers to the battery By doing this the battery is able to absorb the last 10 of charge as quickly as possible without becoming overheated If both lights stay...

Страница 13: ...y reduces the amount of current Amps it delivers to the battery By doing this the battery is able to absorb the last 10 of charge as quickly as possible without becoming overheated If both lights stay...

Страница 14: ...ive or damaged cells 3 Extremely low AC voltage at the battery charger 1 Turn off all DC equipment while charging 2 Load test the batteries and replace if necessary 3 Apply a higher AC voltage source...

Страница 15: ...le protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used...

Страница 16: ...s are not accepted for warranty proof of purchase In the absence of a receipt warranty period will be calculated from date of manufacture printed or stamped on the product There is no other expressed...

Отзывы: