![Gude GE 145 W Скачать руководство пользователя страница 10](http://html1.mh-extra.com/html/gude/ge-145-w/ge-145-w_manual_2277688010.webp)
If the feeder cable of the appliance is damaged it
needs to be replaced by the producer or an
electrician.
Repairs of the appliance can only be executed by an
electrician. There might be significant risks as a
result of unauthorised repairs.
The same regulations apply for accessories
.
Güde GmbH & Co. KG does not answer for damages
caused by:
Appliance damage by mechanical influences and
overloading.
Any changes to the appliance.
Use for any other purpose than that described in
the Operating Instructions.
Unconditionally follow all safety instructions to
prevent accidents and damage.
Important safety instructions
Always wear gloves of insulation fabric.
Wear suitable clothing, avoid any clothing of synthetic
material.
Wear heady-duty insulating shoes.
Make sure that working area is properly ventilated to
prevent accumulation of harmful fumes and toxic smoke
Never work in wet places without efficient safety
measures against electrical discharges
After the work, the electrode has to be taken from the
electrode tongs to prevent undesired arc formation.
The welding machine should not be used or stored in
rain.
If the unit is in operation, the electrode tongs should not
be put on the unit or other electric appliances as the
safety device may get damaged or disconnected when
grounded.
Do not touch the electrode or another metal object in
contact with the electrode while welding is in progress
Check that all cables are coated (mainly the contacts
with the power cable). The cables with insufficient
insulation should be immediately replaced with the same
size cables meeting the regulations.
Disconnect the unit from the source where not used.
The unit may influence supply of other units according to
characteristics of the mains. Seek advice from an
authority responsible for the power supply whenever in
doubt.
Emergency Action
Apply respective first aid and call qualified medical aid fast.
Protect the injured from more injuries and calm him/her down.
For the sake of eventual accident, in accordance with DIN
13164, a workplace has to be fitted with a first-aid kit. It is
essential to replace any used material in the first-aid kit
immediately after it has been used.
If you seek help, state the following pieces of
information:
1. Accident
site
2. Accident
type
3.
Number of injured persons
4. Injury
type(s)
Disposal
The disposal instructions are based on icons on the appliance
or its package..
Handling requirements
The operating staff must carefully read the Operating
Instructions before using the appliance.
Qualification
Apart from the detailed instruction by a professional no
special qualification is necessary for using the appliance.
Minimum age
Only persons over 16 years of age can work with the
appliance. An exception includes youngsters if they work
within their professional education the purpose of which is to
obtain knowledge supervised by a trainer.
Training
Using the appliance only requires corresponding training by a
professional or following of the Operating Instructions. No
special training is necessary.
Technical Data
Connection:
230 V/50 Hz
Protection:
16 A
Controlled scope:
40-100 A
Max. input:
5 kVA
Material recommended thickness:
1,5-4 mm
Effective network performance:
1,3 kVA
Idle run voltage:
46 V
Protection type:
IP 21 S
Electrical cable:
H07RN-F3
Welding cable:
H01N2
Weight:
13 kg
Transportation and Storage
When storing, it is necessary that the appliance is
put to a dry place, inaccessible to children and
unauthorised persons.
Clean the appliance thoroughly before longer
putting out of operation. The unit should be
stored at a dry place inaccessible to
unauthorised persons. Make sure that it is
unplugged. Remember that also the electrodes
should be stored at a dry place.
Residual Hazards and Protective Action
1.
Electrical Residual Hazards:
Indirect electrical contact:
A contact with earthing terminal and the
electrode holder at a time may result in
electrical shock
Avoid a contact
2.
Thermal residual contact:
Burns, frost bites:
Contact with a welded piece may cause severe
burns.
Do not touch the piece, only with welder’s gloves.
Burning pieces flow away during the welding and
may cause damage even to the protection
clothing.
Wear welder’s protection clothing.
3.
Radiation exposure hazard:
Ultraviolet, infrared and visible light.:
Direct sight in the light arch may injure eyes
seriously.
Always work with a welding shield
4.
Materials and other substances hazard:
Contact, aspiration:
Long-time aspiration of welding gases may be
health hazardous
Work with exhaustion. Work in a well-ventilated
area. Prevent direct aspiration of gases.
Fire or explosion:
Combustible materials may set on fire in
immediate vicinity of welding site t.
Do not weld near combustible materials.
Oil, fuel or a gas tank may explode in the
course of welding.
Содержание GE 145 W