9
expert net control 2i2o
Configuration
- Activation/deactivation of syslog
- Switching of Power Ports
You can find more information about configuration of Syslog in chapter Configuration - Syslog or have a look at http://www.
gude.info/wiki.
4.3.5.1
Enable Syslog
Here you can activate Syslog of expert net control 2i2o.
4.3.5.2
Syslog Server IP
If syslog is active enter here the IP address of you Syslog server.
4.3.5.3
Syslog Port
If syslog is active enter here the port number, that your Syslog server uses to receive syslog information.
More information about Syslog you can find in chapter Syslog, on http://www.gude.info/wiki or ask our support team.
5
Operation
6
Features
6.1
Bootloader mode
To activate the bootloader mode of expert net control 2i2o the select button must be pushed while restarting the device. In
bootloader mode it is possible to disable the password protection, to update the firmware and to restore the default settings
by running the program GBL_Conf.exe.
If the device runs already, press the buttons "select" and "ok" for three seconds. The bootloader mode of expert net control
2i2o is indicated by “BOOT-LDR” appended to the device name in the program window of GBL_Conf.exe.
During bootloader mode an alteration of the relais is not possible.
To restart the firmware, without toggle the Power Ports, press the buttons select and ok for three seconds again.
6.2
Firmware update
In order to update the firmware the program GBL_Conf.exe and the latest firmware are needed.
Start the device in bootloader mode and run the program GBL_Conf.exe. On the left side of the program window all Gude
devices that are in the network are listed. Select the device, that should be updated, click on Program DeviceFirmware
Update and determine the location of the new firmware.
Please note: The up-to-date firmware and GBL_Conf.exe can be found at www.gude.info, free to download.
6.3
Technical information
6.4
Fabrique settings
In order to restore the default settings the device must be started in bootloader mode. Besides that the program GBL_Conf.
exe is required.
Run GBL_Conf.exe and select the device whose settings should be restored. Then click on Program Device -> Reset to Fab
default.
Содержание Expert net control 2i2o
Страница 1: ...2010 expert net control 2i2o...
Страница 2: ...expert net control 2i2o 2010 16 12 2010...
Страница 11: ...11 expert net control 2i2o Declarations of conformity 8 Declarations of conformity...
Страница 12: ...12 expert net control 2i2o Declarations of conformity...
Страница 13: ...13 expert net control 2i2o Declarations of conformity...
Страница 14: ...expert net control 2i2o 2010 16 12 2010...