66
Expert Power Control 8221/8226
© 2022 GUDE Systems GmbH
Specifications
Actual Curent on Pow er Channel.
epc8226spVoltage
.58.1.5.5.2.1.6.x
Gauge32
RO
Actual Voltage on Pow er Channel
epc8226spFrequency
.58.1.5.5.2.1.7.x
Gauge32
RO
Frequency of Pow er Channel
epc8226spPow erFactor
.58.1.5.5.2.1.8.x
Integer32
RO
Pow er Factor of Channel betw een -1.0 and 1.00
epc8226spPangle
.58.1.5.5.2.1.9.x
Integer32
RO
Phase Angle betw een Voltage and L Line Current betw een -180.0 and
180.0
epc8226spPow erApparent
.58.1.5.5.2.1.10.x
Integer32
RO
L Line Mean Apparent Pow er
epc8226spPow erReactive
.58.1.5.5.2.1.11.x
Integer32
RO
L Line Mean Reactive Pow er
epc8226spAbsEnergyReactive
.58.1.5.5.2.1.12.x
Gauge32
RO
Absolute Reactive Energy counter.
epc8226spAbsEnergyActiveReset
table
.58.1.5.5.2.1.13.x
Gauge32
RW
Resettable Absolute Active Energy counter. Writing '0' resets all
resettable counter.
epc8226spAbsEnergyReactiveRe
settable
.58.1.5.5.2.1.14.x
Gauge32
RO
Resettable Absolute Reactive Energy counter.
epc8226spResetTime
.58.1.5.5.2.1.15.x
Gauge32
RO
Time in seconds since last Energy Counter reset.
epc8226spForw EnergyActive
.58.1.5.5.2.1.16.x
Gauge32
RO
Forw ard Active Energy counter.
epc8226spForw EnergyReactive
.58.1.5.5.2.1.17.x
Gauge32
RO
Forw ard Reactive Energy counter.
epc8226spForw EnergyActiveRes
ettable
.58.1.5.5.2.1.18.x
Gauge32
RO
Resettable Forw ard Active Energy counter.
epc8226spForw EnergyReactiveR
esettable
.58.1.5.5.2.1.19.x
Gauge32
RO
Resettable Forw ard Reactive Energy counter.
epc8226spRevEnergyActive
.58.1.5.5.2.1.20.x
Gauge32
RO
Reverse Active Energy counter.
epc8226spRevEnergyReactive
.58.1.5.5.2.1.21.x
Gauge32
RO
Reverse Reactive Energy counter.
epc8226spRevEnergyActiveReset
table
.58.1.5.5.2.1.22.x
Gauge32
RO
Resettable Reverse Active Energy counter.
epc8226spRevEnergyReactiveRes
ettable
.58.1.5.5.2.1.23.x
Gauge32
RO
Resettable Reverse Reactive Energy counter.
epc8226Pw rSupplyIndex
.58.1.5.13.1.1.x
Integer32
RO
Index of Pow er Supply entries
epc8226Pw rSupplyStatus
.58.1.5.13.1.2.x
INTEGER
RO
show s status of the Pow er Supply for each bank
epc8226NTPTimeValid
.58.1.5.15.1.0
INTEGER
RO
Show if valid Time is received
epc8226NTPUnixTime
.58.1.5.15.2.0
Unsigned32
RO
show received NTP time as unixtime (secs since 1 January 1970)
epc8226NTPLastValidTimestamp
.58.1.5.15.3.0
Unsigned32
RO
show seconds since last valid NTP timestamp received
epc8226SensorIndex
.58.1.6.1.1.1.x
Integer32
RO
None
epc8226TempSensor
.58.1.6.1.1.2.x
Integer32
RO
actual temperature
epc8226HygroSensor
.58.1.6.1.1.3.x
Integer32
RO
actual humidity
epc8226InputSensor
.58.1.6.1.1.4.x
INTEGER
RO
logical state of input sensor
epc8226AirPressure
.58.1.6.1.1.5.x
Integer32
RO
actual air pressure