33
Failure removal
Failures
Causes
Removal
Engine does not start
No power supply.
Check the voltage. Technical data
given on the type label must corre-
spond with electric network voltage.
Broken cable
Any checks or replacements to be
provided by a professional electrician
Engine growling, running but not
starting
Gear ring blocked
Switch the machine off, unplug it
and clean it or replace the ring gear
components.
Defective condenser
Deliver the machine to the customer
service centre for repair
Equipment starting but getting
blocked under small load and
switching automatically off
The extension cable is too long or
with a small cross section
Extension cable to be at least 1.5
mm2 for a length of up to 25 m
The socket is too far from the main
line and the extension cable has a
small cross section
Cross section of at least 2.5 mm2 for
longer cables
The contact pressure of the hand
wheel is too loose
The pressure spring is not sufficiently
tight
Tighten the screw on the pressure
spring
Drum not rotating after starting the
machine
Defective V-belt or mismatching
voltage
V-belt replacement
EN
ENGLISH