Failure removal

Defect

    

Causes

Measure

Compressor not starting after 

being switched on

Pressure in the air jet exceeds the 

closing pressure

Release the pressure in the air jet 

so that the pressure switch gets 

automatically switched on

Defective supply

Have the current supply checked by 

an authorised person

Defective pressure switch

Have the pressure switch replaced 

by an authorised person (Güde 

service centre)

Worn carbons

Replace the carbons

After reaching the closed pressu-

re, the compressor runs or buzzes 

for a short time and then switches 

off automatically

Electric cable is too long or its cross 

section is too small

Check the length and cross section 

of the electric cable

Compressor running constantly

Suction filter is very dirty

Clean or replace the suction filter

Pneumatic tools have high air 

consumption

Check the pneumatic tool air 

consumption;     

seek an authorised compressed air 

dealer

Leaking on the compressor

Localise the leaking, contact the 

Güde service centre

Compressed-air pipeline leaking

Contact the Güde service centre

Drain valve is open or missing

Close or insert the drain valve

Compressor gets started too often Too much condensate in the air jet Drain the condensate 

Compressor is overloaded

Safety valve blowing off

Pressure in the air jet exceeds the 

set cut-off pressure

Have the pressure switch adjusted/

replaced by an authorised person 

(Güde service centre)

Safety valve is defective

Replace the safety valve or contact 

the Güde service centre

Compressor getting warm too 

much

Air supply is not sufficient

Make sure sufficient air supply and 

outlet (minimum distance from wall 

is 40 cm) is provided

Cooling fins on the cylinder (cylin-

der head) are dirty

Clean the cooling fins on the cylin-

der (cylinder head)

Too long time of appliance 

operation

Switch the compressor off

Compressor being overheated 

and keeps switching off

Compressor is overloaded

Contact the Güde service centre

Compressor is defective

Contact the Güde service centre

Compressor under undervoltage

Contact the Güde service centre

Outdoor temperature of 35°C

ENGLISH

Содержание 50079

Страница 1: ...originale NL Vertaling van de originele gebruiksaanwijzing CZ P eklad origin ln ho n vodu k provozu SK Preklad origin lneho n vodu na prev dzku HU Az eredeti haszn lati utas t s ford t sa SLO Prevod...

Страница 2: ...rlezen v rdat u de machine in gebruik neemt SLOVENSKY Pred prv m pou it m pr stroja si pozorne pre tajte n vod na obsluhu CESKY P ed spu t n m stroje si pe liv pro t te n vod k pou v n MAGYAR K rj k a...

Страница 3: ...DRZBA Z RUKA VYHL SENIE O ZHODE E _________________________________________________ 31 Magyar M SZAKI ADATOK RENDELTET S SZERINTI HASZN LAT BIZTONS GI UTAS T SOK KARBANTART S J T LL S AZONOSS GI NYILA...

Страница 4: ...ELIVERED ITEMS ARTICLES D LIVR S VOLUME DELLA FORNITURA LEVERINGSOMVANG OBJEM DOD VKY ROZSAH DOD VKY SZ LL T SI TERJEDELEM OBSEG DOBAVE OPSEG ISPORUKE VOLUMUL LIVR RII OPSEG ISPORUKE TESLIMAT KAPSAMI...

Страница 5: ...enzione NL Schoonmaken Onderhoud CZ i t n dr ba SK istenie drzba HU Tiszt t s Karbantart s SI i enje Vzdr evanje HR i enje Odr avanje BG RO Cur are ntre inere BA i enje Odr avanje 5 4 2 DE Inbetriebna...

Страница 6: ...the machine FR mise en service IT Messa in funzione NL Inbedrijfstelling CZ Uveden do provozu SK Uvedenie do prev dzky HU zembe helyez s SI Uvedba v pogon HR Pu tanje u rad BG RO Punerea n func iune B...

Страница 7: ...etrieb GB Operation FR Fonctionnement IT Esercizio NL Gebruik CZ Provoz SK Prev dzka HU zemeltet s SI Delovanje HR Rad BG RO Func ionare BA Rad click 1 click 3 5 6 S T A R T 4 8 bar A U T O S T O P 0...

Страница 8: ...E Betrieb GB Operation FR Fonctionnement IT Esercizio NL Gebruik CZ Provoz SK Prev dzka HU zemeltet s SI Delovanje HR Rad BG RO Func ionare BA Rad 7 8 10 9 S T O P 0 bar 11 1 2 A U T O S T A R T 6 bar...

Страница 9: ...serbatoio NL Na circa 2 4 uur gebruik moet het condenswater dat zich in de tank vormt afgetapt worden CZ P ibli n po 2 4 hodin ch pr ce je t eba vypustit kondenzovanou vodu kter se vytvo ila v n dr i...

Страница 10: ...m den Kompressor zu bewegen D Benutzen Sie das Ger t erst nachdem Sie die Bedienungsanlei tung aufmerksam gelesen und verstanden haben Beachten Sie alle in der Anleitung aufgef hrten Sicherheitshinwei...

Страница 11: ...weiligen spezifischen Vorschriften Dieser Kompressor wurde f r einen Intervallbetrieb wie auf dem Schild der technischen Daten ange geben konstruiert S3 25 bedeutet z B 2 5 Minu ten Betrieb und 7 5 Mi...

Страница 12: ...und zuverl ssigen Betrieb von rotierenden und schlagenden Druckluftwerkeu gen wie zB Schlagschrauber Tacker oder Nagler usw zu gew hrleisten muss die Druckluft zwingend ber einen ler oder eine Wartun...

Страница 13: ...atischen Anlauf Warnung vor wegschleudernden Teilen Abstand von Personen Achten Sie darauf dass sich keine Per sonen im Gefahrenbereich aufhalten Schadhafte und oder zu entsorgende elektrische oder el...

Страница 14: ...pressor Leckage lokalisieren G de Service verst ndigen Druckluftleitung undicht G de Service verst ndigen Kondensatablassventil ge ffnet oder fehlt Schlie en bzw Einsetzen Kompressor schaltet h ufig e...

Страница 15: ...or mental capabilities or without the necessary lack experience or knowledge unless they are supervised by a person who is responsible for their safety or were instructed GB Read and understand the o...

Страница 16: ...taminating product condensate must be DISPOSED of in accordance with laws on protection of the environment and current legislation Never leave the appliance exposed to adverse wea ther conditions rain...

Страница 17: ...ical attendance as quickly as possible Protect the injured person from further harm and calm them down For the sake of eventual accident in accordance with DIN 13164 a workplace has to be fitted with...

Страница 18: ...centres Protect against humidity This side up EC Declaration of Conformity G DE GmbH Co KG Birkichstrasse 6 74549 Wolpertshausen Deutschland We hereby declare the conception and construction of the b...

Страница 19: ...ressor Localise the leaking contact the G de service centre Compressed air pipeline leaking Contact the G de service centre Drain valve is open or missing Close or insert the drain valve Compressor ge...

Страница 20: ...G DE GmbH Co KG Birkichstrasse 6 74549 Wolpertshausen Deutschland Tel 49 0 7904 700 0 Fax 49 0 7904 700 250 eMail info guede com 0102 03...

Отзывы: