background image

   

G

ua

rd

ia

Fa

ll 

Pr

ot

ec

tio

  6

30

S.

 2

31

st

 S

t.

, K

en

t,

 W

A

 9

80

32

   

   

 p

ho

ne

: (

80

0)

 4

66

-6

38

 f

ax

: (

80

0)

 6

70

-7

89

   

  w

w

w

.g

ua

rd

ia

nf

al

l.c

om

2

Product Specific Applications

Personal Fall Arrest:

 SkyMast may be used to support a MAXIMUM 3 PFAS for use in Fall Arrest

applications. Structure must withstand loads applied in the directions permitted by the system of
at least 5,000 lbs. Applicable D-ring: Dorsal.

• MUST be used in combination with Leading Edge (LE) SRL. Maximum free fall is 2’.

Restraint:

 SkyMast may be used in Restraint applications. Restraint systems prevent workers

from reaching the leading edge of a fall hazard. Always account for fully deployed length of
lanyard/SRL. Structure must withstand loads applied in the directions permitted by the system of
at least 1,000 lbs. No free fall is permitted. Restraint systems may only be used on surfaces with
slopes up to 4/12 (vertical/horizontal). Applicable D-rings: Dorsal, Chest, Side, Shoulder.

!

WARNING

Use of equipment in unintended applications may result in serious

injury or death. Maximum 1 attachment per connection point.

For all applications: worker weight capacity range

(including all clothing, tools, and equipment) is 130-310 lbs. per worker.

FALL CLEARANCE CALCULATION

Lanyard length

(6’ total)

Safety factor

(3’ total)

Deceleration

distance (4’ total)

Height of harness

dorsal D-ring from

worker’s feet

(6’ total)

Required

distance

from

anchorage

(19’ total)

Limitations

Fall Clearance:

 There must be sufficient

clearance below the anchorage connector
to arrest a fall before the user strikes the
ground or an obstruction. When calculating
fall clearance, account for a MINIMUM 3’
safety factor, deceleration distance, user
height, length of lanyard/SRL, and all other
applicable factors.

Diagram shown is an example fall
clearance calculation ONLY.

Swing Falls:

 Prior to installation or use, make

considerations for eliminating or minimizing
all swing fall hazards. Swing falls occur when
the anchor is not directly above the location
where a fall occurs. Always work as close to in
line with the anchor point as possible. Swing
falls significantly increase the likelihood of
serious injury or death in the event of a fall.

Содержание SkyMast 00271

Страница 1: ...derstand these instructions before using equipment Introduction 1 Applicable Safety Standards 1 Worker Classifications 1 Safety Information 10 Product Specific Applications 2 Limitations 2 3 Component...

Страница 2: ...ciated components Worker Classifications CAUTION Understand the following definitions of those who work near or who may be exposed to fall hazards Qualified Person A person with an accredited degree o...

Страница 3: ...tions may result in serious injury or death Maximum 1 attachment per connection point For all applications worker weight capacity range including all clothing tools and equipment is 130 310 lbs per wo...

Страница 4: ...OK Two or more snap hooks or carabiners connected to each other NO Two connectors to same D ring NO Connector directly to horizontal lifeline NO Connector to integral lanyard NO Connector directly to...

Страница 5: ...rately SRL Cradles SkyMast Cleats SkyMast Skyhook Anchor not included SkyMast Center Post Part Weight Description 00271 00315 00325 00335 00345 40 8 lbs 14 lbs 14 lbs 14 lbs 14 lbs SkyMast Skyhook App...

Страница 6: ...Anchor MUST be used in combination with SkyMast SkyMast Skyhook Anchor MUST be Part 00315 00325 00335 or 00345 SkyMast Skyhook Installation MINIMUM substrate requirements Wood 3 4 CDX or better Metal...

Страница 7: ...nd into roof truss or other compatible support beam Concrete installation Must be done directly on substrate and never through any intermediary substrates Use same fastener configuration as wood metal...

Страница 8: ...t Center Post over SkyMast Skyhook Anchor Connection Point Secure Center Post to SkyMast Skyhook Anchor with supplied and attached Dowel Pin SkyMast Center Post Skyhook Connection Point Dowel Pin 3 At...

Страница 9: ...ected and deemed compatible by a Competent Person 12 per side 14 10 2 screws installed through sheathing and into truss or support beam 5 Attach compatible SRL to installation location s on SkyMast Se...

Страница 10: ...that applicable work area is free of all damage including but not limited to debris rot rust decay cracking and hazardous materials Ensure that selected work area will support the application specific...

Страница 11: ...E SRLs Class A SRLs must arrest falls within 24 Class B SRLs must arrest falls within 54 Harnesses and connectors selected must be compliant with manufacturer s instructions and must be of compatible...

Страница 12: ...connections are chosen by a Competent Person and are compatible with the SkyMast Anchor Refer to instructions for installation Structure must be capable of withstanding minimum load of 5 000 lbs WARNI...

Отзывы: