Installation and Use

Prior to installation, plan your system:

1. PFAS equipment must be selected and deemed compatible with SkyMast by a Competent Person.

2. Eliminate or minimize all risk of swing fall.

3. Determine desired location for anchor; ensure location is free of debris, rot, decay, cracking, and hazardous
materials. NEVER install on gable ends, fascias, rake ends, overhangs, bottom cords, collar boards, spliced
sections, or substrate incapable of withstanding application minimum loads.

4. Ensure selected SkyMast Skyhook Anchor is compatible with pitch of installation location. SkyMast Skyhook
Anchor MUST be used in combination with SkyMast. SkyMast Skyhook Anchor MUST be Part # 00315, 00325,
00335, or 00345.

SkyMast Skyhook Installation:

MINIMUM substrate requirements:

• 

Wood: 3/4” CDX or better.

• 

Metal: 20g or thicker.

• 

Concrete: 2,000 p.s.i. or better.

SkyMast Skyhook Anchor MUST install flush against substrate.

SkyMast Skyhook Anchors may be placed a MAXIMUM 16’ apart.

SkyMast Skyhook Anchors MUST be placed a MINIMUM 10’ from all leading edges of fall hazards.

1. Place SkyMast Skyhook Anchor over selected roof ridge. Anchor must lie flush with substrate.

2. Ensure all fasteners are those supplied by Guardian Fall Protection, or are deemed compatible by a
Competent Person.

• For installations on wood and metal, use (18) #14x10 2” screws or better. NEVER use nails.

• For installations on concrete, use (18) concrete fasteners that have been selected and deemed compatible
with SkyMast Skyhook Anchors by a Competent Person.

Содержание SkyMast 00271

Страница 1: ...derstand these instructions before using equipment Introduction 1 Applicable Safety Standards 1 Worker Classifications 1 Safety Information 10 Product Specific Applications 2 Limitations 2 3 Component...

Страница 2: ...ciated components Worker Classifications CAUTION Understand the following definitions of those who work near or who may be exposed to fall hazards Qualified Person A person with an accredited degree o...

Страница 3: ...tions may result in serious injury or death Maximum 1 attachment per connection point For all applications worker weight capacity range including all clothing tools and equipment is 130 310 lbs per wo...

Страница 4: ...OK Two or more snap hooks or carabiners connected to each other NO Two connectors to same D ring NO Connector directly to horizontal lifeline NO Connector to integral lanyard NO Connector directly to...

Страница 5: ...rately SRL Cradles SkyMast Cleats SkyMast Skyhook Anchor not included SkyMast Center Post Part Weight Description 00271 00315 00325 00335 00345 40 8 lbs 14 lbs 14 lbs 14 lbs 14 lbs SkyMast Skyhook App...

Страница 6: ...Anchor MUST be used in combination with SkyMast SkyMast Skyhook Anchor MUST be Part 00315 00325 00335 or 00345 SkyMast Skyhook Installation MINIMUM substrate requirements Wood 3 4 CDX or better Metal...

Страница 7: ...nd into roof truss or other compatible support beam Concrete installation Must be done directly on substrate and never through any intermediary substrates Use same fastener configuration as wood metal...

Страница 8: ...t Center Post over SkyMast Skyhook Anchor Connection Point Secure Center Post to SkyMast Skyhook Anchor with supplied and attached Dowel Pin SkyMast Center Post Skyhook Connection Point Dowel Pin 3 At...

Страница 9: ...ected and deemed compatible by a Competent Person 12 per side 14 10 2 screws installed through sheathing and into truss or support beam 5 Attach compatible SRL to installation location s on SkyMast Se...

Страница 10: ...that applicable work area is free of all damage including but not limited to debris rot rust decay cracking and hazardous materials Ensure that selected work area will support the application specific...

Страница 11: ...E SRLs Class A SRLs must arrest falls within 24 Class B SRLs must arrest falls within 54 Harnesses and connectors selected must be compliant with manufacturer s instructions and must be of compatible...

Страница 12: ...connections are chosen by a Competent Person and are compatible with the SkyMast Anchor Refer to instructions for installation Structure must be capable of withstanding minimum load of 5 000 lbs WARNI...

Отзывы: