PX/QX/RX Version 4.20  

 

User Manual 

 

Issue B 

Содержание PX500

Страница 1: ...PX QX RX Version 4 20 User Manual Issue B ...

Страница 2: ...ING FROM A KEYPAD 10 SETTING WITH A MINI KEYPAD 10 KEYSWITCH RADIO KEYFOB SETTING 11 AUTOMATIC SETTING 11 Aborting The Setting Procedure 11 SETTING WITH WARNINGS 11 EASY SET 11 SETTING RESTRICTIONS 12 SETTING FAULTS 12 DUAL SET PX250HS ONLY 13 UNSET 14 UNSETTING METHODS 14 Unsetting from a keypad 14 Unsetting with Keyswitch or Radio Keyfob 14 Automatic Unsetting 15 UNSETTING WARNINGS 15 UNSETTING ...

Страница 3: ...S ONLY 26 LATE WORK 26 BYPASS 27 CHIME 27 SHUNT 28 PRINT TEXT 28 PRINT HOLS 28 IDENTIFY USER 28 COPY USER 29 COPY A USER PX ONLY 29 CCT STATUS 29 ACCESS FEATURES PX ONLY 30 ADD A USER 30 DELETE USER 31 DOOR UNLOCK 31 DOOR LOCKOUT 32 ACM TEXT 32 APPENDIX A USER AUTHORITIES 33 APPENDIX B EDITING TEXT 34 APPENDIX C LOG MESSAGES 35 APPENDIX C ACCESS LOG MESSAGES 38 APPENDIX E MENU RESTRICTIONS 39 ...

Страница 4: ...PX QX RX Version 4 20 User Manual Issue B 4 APPENDIX E LOG ON MESSAGES 40 APPENDIX F AUDIO COMMANDS 41 APPENDIX G SYSTEM DETAILS 42 KEYPADS 42 SET GROUPS 42 CIRCUITS 43 USERS 44 ...

Страница 5: ...e viewed or printed if a printer is fitted to the system Areas Set Groups For protection purposes the premises may be divided into a number of areas Individual areas may be grouped together into a setting group Not RX16i which provides the user with a convenient way of setting and unsetting more than one area at the same time The installation company engineer will have configured your system for t...

Страница 6: ...nd to perform all authorised user functions The backlighting will be turned on during the entry time during code entry and while a user is logged on It may also be turned on using any button except and and turned off using the or buttons Keypads may be fitted with an internal proximity reader The keypad incorporates a mains power indicator This indicator will flash if the system is operating on st...

Страница 7: ...og Alarm 20 Time 24 Holiday 25 Schedule 26 Group Text 28 Late Work 30 Bypass 32 Chime 52 Identify User 71 Copy User 89 Cct Status Confirm LogOff 02 Set 04 Test Enter the 2 digit code to select an option Use the and buttons to change the displayed options Press to move quickly through the menu Set Reset Alarms User Log Full Late Work Bypass Time Unset Move Select user token on mini keypad The menu ...

Страница 8: ...system Product Info The product info option displays the control panel order code and firmware version number and if fitted the Dialler version number An authorised user can change some of the system parameters When changing an item the help button can be used to display the allowed values Remote Assist Before using the remote assist option you must obtain a number from your alarm company When you...

Страница 9: ...r of incorrect code attempts that can be made If more than the programmed number of code attempts are made to enter a valid user code the keypad will be locked out and the display will show Out of Service for a period of 5 minutes Any attempt to enter a user code during the locked out period will extend the period by another 5 minutes 12 00 Mon 27 Sep Guardall 12 00 Mon 27 Sep Enter 0 2 0 2 12 00 ...

Страница 10: ... where setting is completed by pushing the external PB circuits after opening and closing the final exit circuit Your installation engineer should advise which of the above options have been programmed on your system Setting from a keypad 02 Set 04 Test Workshop Seconds Left 005 1 Workshop 2 Office 1 0 2 12 00 Mon 27 Sep Guardall Workshop Setting Workshop Set 12 00 Mon 27 Sep Enter 0 2 0 2 Log on ...

Страница 11: ...ould be aware of before setting the system These conditions are described as set warnings and do not prohibit the user from setting the system in the normal way Workshop Seconds Left 005 1 Workshop 2 Office 1 Loading Door Isolated Set The set warnings include 1 Bypassed circuit s 2 Circuit s on soak test has failed a special circuit test mode set up by the installation engineer 3 Isolated circuit ...

Страница 12: ...layed This can occur at the start of setting or at the end of the exit time depending on how your system is set up and when the fault occurs If a fault occurs during the exit time the exit tone will change to a warning tone The external sounder may also have been programmed by the installation engineer to activate in the event of a failure to set Workshop Seconds Left 005 1 Workshop 2 Office 1 Can...

Страница 13: ...Sep Guardall Dual Code Enter 12 00 Mon 27 Sep Enter 2 Vault Setting 0 2 0 2 1 3 4 Logon time limit reached In the example the vault area is programmed for dual user set The first user code is 0202 and the second user code is 1234 Both users must have the authority to set the vault area Both user actions are logged 2 ...

Страница 14: ...d If the group is not unset before the entry time has expired a warning period of 30 seconds will be given This is to warn the user that an alarm condition will occur if the group is not unset by the end of the warning period If the group is not unset by the time that the total entry time and warning time has expired an alarm condition will be initiated To comply with the requirements of DD243 200...

Страница 15: ...le alarm limit 7 Battery test faults 8 230v mains faults Unsetting Restrictions The selected group is programmed with a set level and a higher level set group s has not been unset If a user attempts to unset a high level set group when a lower level is set then a warning message will be displayed In a PX250HS there are several additional conditions that apply when unsetting 1 The keypad must be pr...

Страница 16: ...by the installation engineer 12 00 Mon 27 Sep Guardall Log off after unset programmed Dual Unset PX250HS Only 01 Unset 04 Test 1 Vault 2 Office 1 0 12 00 Mon 27 Sep Guardall Dual Code Enter 12 00 Mon 27 Sep Enter 2 1 02 Set 04 Test Vault Unset 0 2 0 2 1 3 4 Logon time limit reached In the example the vault area is programmed for dual user unset The first user code is 0202 and the second user code ...

Страница 17: ...23456 If your system is programmed for engineer reset a telephone number and code will be displayed Call this number and quote your code if your system is configured for managed reset you will be given a code to reset your system This code can only be used once If an engineer or managed reset is required it will not be possible to set the system Alarm cannot be reset Managed Reset If the system is...

Страница 18: ...est 6 Detector 1 Sounder 2 Audio 4 All circuits tested The panel records all activations from sensors during the unset period When walk test is selected the panel will display all circuits which have not alarmed since the panel was last unset If all circuits are to be tested then select walk test then press the button and select walk test a second time When the panel exits walk test mode either ma...

Страница 19: ...rs on the system are identified by a 4 5 or 6 digit PIN code To change user PIN code log on to the keypad using your current PIN code and choose the PIN option Then follow the display prompts All user PIN code changes are recorded in the system event log If the PIN code option is not available this means that the system has been programmed to prevent you from changing your user PIN code and a new ...

Страница 20: ... be added quickly using the Add User menu option 50 rather than programming them individually User Menu Name Code 1 When the name option is selected the current user descriptor will be displayed and can be edited Refer to appendix B for details User names can be up to 10 characters long User Menu PIN Code 2 For details of changing a code refer to the main menu code change option The default user c...

Страница 21: ...tem will show a list of set groups that are available to set If only one set group is available setting will start automatically LogOn Unset On Off If this option is on then the authorised set groups which are set will be unset when the user logs on Shunt On Off If this option is on the user has access to the shunt menu option 33 Card PIN On Off If the user is configured with the Card PIN option t...

Страница 22: ...d Off 1 Name 2 PIN User 3 Enable Off 4 User 3 Enable On 1 0 Normal 1 Visitor 2 Escort 3 Supervisor ACM Authority Level Access level Help Menu User access right will depend on the programmed user level and the programmed access door mode programmed by the installation engineer There are no restrictions on exit User Access Restrictions Door Mode User Mode Normal Dual Escort Supervisor Normal 1 Visit...

Страница 23: ...eech format home beep or SMS formats The available formats will depend on the system hardware options A telephone number of up to 16 digits can be programmed This number can include pause digits Pause digits can be entered using the Ð button This will be displayed as a character Each pause digit represents a 1 second delay Pauses may be required if you are signalling via a PABX or if the call is r...

Страница 24: ...____ Door Number __ 1 Display 2 Print 12 00 00 Cct1 Bypassed Fri 3 Jan 2003 00071 U2 Cct1 Bypassed PIR in Hall Bypassed 2 1 0 1 1 1 2 1 3 1 4 1 7 1 8 1 6 1 12 Log User 13 Log KP 14 Log Date 15 Log Alarm 16 A Log Full 17 A Log User 18 A Log Door 10 Log Full 11 Log Cct 1 5 00001 Mon 07 Apr 2003 00 00 02 User 2 Mr Smith Logged On on KP 0 Event index Event date Event time Event details Use the button ...

Страница 25: ...isable a holiday enter a date of 00 00 The start and end dates must be in chronological order Holidays may be optionally programmed to apply to individual set groups Schedule Code 25 A schedule consists of 4 times for each day of the week and 4 times for days which are holidays A schedule can be used to 1 Auto set and unset parts of the system 2 Control outputs 3 Enable disable keypads 4 Enable di...

Страница 26: ...n when the ATM user has 10 minutes working time left and the extend time prompt will be displayed automatically Requests to extend the time will be logged At the end of the working time the ATM user will be automatically logged off and areas that were unset by the ATM user will be automatically set If an ATM user logs off without setting the ATM user authorised areas will be automatically set Late...

Страница 27: ...uits that can be bypassed at any one time The system will display an error message if you try to exceed this limit 30 Bypass Circuit Number ___ Enter circuit number Cct 01 Bypassed 1 0 Circuit Limit 1 to max Cct 01 Normal Not Available No Authority Circuit was not bypassed Circuit was bypassed Circuit cannot be bypassed Cct 01 Normal Not Available At Bypass Limit Max Number of circuits already byp...

Страница 28: ...nted Circuit was shunted Circuit cannot be shunted Not Available Shunt Limit Max Number of circuits already shunted 3 3 Print Text Code 40 This option will only be available if a printer is connected to the system The print text option will print all text descriptors Print Hols Code 42 This option will only be available if a printer is connected to the system The print holiday option will print al...

Страница 29: ... This option will only be available if at least one ACM is fitted to the system 73 Copy A User Copy A User ____ ____ ____ Enter the user to copy here Enter the first and last user in the copy range here 7 3 To copy a single user enter the same user number as the first and last Cct Status Code 89 89 Cct Status Cct Status Normal 8 9 Cct 1 Bypassed When the Cct Status option is selected the circuits ...

Страница 30: ... may be access or panel users users 201 1000 can only be access users and user 1 is always the engineer The PX access control system can be configured through a security system keypad or a PC running GuardStation Access Guardall PX proximity cards or fobs may only be introduced to the system through a PX keypad with an integrated proximity reader Add A User Code 50 This option will only be availab...

Страница 31: ...3___ 3 Door Unlock Code 53 This option will only be available if at least one ACM is fitted to the system An ACM door can be manually locked unlocked from a keypad An optional unlock time of up to 255 minutes can be programmed If a time of zero is programmed the door will remain unlocked until the unlock option is turned off While a door is locked it can still be opened by presenting a valid user ...

Страница 32: ...le permissions or otherwise immediately and for the applied duration Upon removal the ACM door will be returned to its previous state if that state still applies Proximity reader LED s will show the ACM door as locked out for the applied duration 54 Door Lockout Door Number _ Door 1 Door Lockout Off Door 1 Door Lockout On 1 0 Off 1 On 1 4 5 An access user with supervisor authority can gain access ...

Страница 33: ... 51 Delete User 6 52 Identify User 53 Door Unlock 6 54 Door Lockout 6 55 ACM Text 6 71 Copy User 73 Copy A User 89 Cct Status Notes 1 The Engineer option is not available to a user if the panel is programmed to allow the engineer to log on without user authorisation 2 The code option for some users will only be available if configured as part of the user authority 3 The time can only be changed by...

Страница 34: ...ber 03 J Smith User Number 03 K Smith User Number 03 A Smith 1 4 5 6 7 8 9 1 A 2 3 M Z a m z 1 9 0 clear space save move User Number 03 A Smith The allowed characters are ABCDEFGHIJKLMNOPQRSTUVWXYZabcdefghijklmnopqrstuvwxyz _0123456789 When a descriptor is displayed the character being edited will be flashing this is shown as a grey character in the diagram You can change a character using the num...

Страница 35: ...mm Usnn Cctmmm Circuit bypassed Cannot set User nn Area m Usnn Am User was not able to set an area Cct Tested Circuit nnn Cctnnn Circuit responded in walk test Changed Code User nn Keypad m Usnn KPm User changes own code Changed Code User nn User mm Usnn Usmm Manager or GSR user changes code for another user Changed Time User nn Keypad m Usnn KPm Time modified old time and new time are logged Chec...

Страница 36: ... fault no response when unset The system fault response option must be programmed This option is only available in EN50131 compliant variants Fault Circuit nnn Cctnnn A Circuit short circuit when unset Fault Keypad n KPn Failed poll when unset Fault Conc nn Conc nn Failed poll when unset Fault OPM nn OPM nn Failed poll when unset Fault SM n SM n Failed poll when unset Fault ACM nn ACM nn Failed po...

Страница 37: ...d on from GSR number x PC Disconnect GSRx Operator YY GSRx Operator YY GSR operator number YY has logged on from GSR number x Personal Attack Circuit nnn Cctnnn A PA type circuit alarm Poll Fail Transmitter number TX nn RM mm Transmitter polling failure Poll Fault Radio module number RM nn Receiver polling fault Power Fail NONE see note NONE Supply voltage has fallen to the power fail threshold PS...

Страница 38: ... m Usnn Am A user has unset the area Unset User nn Group m Usnn m Group has been unset by a user Unset Req Circuit nnn Cctnnn Key type circuit clears Unset Req User nn Keypad m Usnn KPm A user requested unset on a keypad dual unset or unset delay programmed Upload Fail GSRx GSRx Upload to GSR x failed Upload OK GSRx GSRx Upload to GSR x OK Verify Alm Area n An A verified alarm has occurred Watchdo...

Страница 39: ... button which has been pressed is never used in the current menu Keypad Busy User attempts to turn off a keypad that is being used Low Level Unset User attempts to set a higher level group without setting lower levels No Authority User tries to select an option that is not allowed with their programmed authority level No Set Area User selects unset when all areas that can be unset from the keypad ...

Страница 40: ...ately changing your code This message will always be displayed on log on until the code is changed Det Test Fail Area x A detector in area x has failed an automatic detector test Note that this warning will not be shown if the log on set option applies Group Unset A group s is set and is programmed to automatically unset when a user logs on Mult Alarm A circuit s has alarmed the maximum number of ...

Страница 41: ...essage 41 49 Record channel messages 1 to 8 410 Record set message 411 Record unset message 50 Play main message 51 59 Play channel message 1 to 8 510 Play set message 511 Play unset message 61 68 Turn on output 1 to 8 the selected output must be programmed by the engineer 171 178 Turn off output 1 to 8 the selected output must be programmed by the engineer 010 Unset system 01nn Unset group n wher...

Страница 42: ...e B 42 Appendix G System Details Number of Areas Number of keypads Number of Circuits Number of Users Service Number Contract Number Keypads Number Location 1 2 3 4 5 6 7 8 Set Groups Areas Number Description 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 ...

Страница 43: ...ual Issue B 43 Circuits Number Description Location Cct 1 Cct 2 Cct 3 Cct 4 Cct 5 Cct 6 Cct 7 Cct 8 Cct 9 Cct 10 Cct 11 Cct 12 Cct 13 Cct 14 Cct 15 Cct 16 Cct 17 Cct 18 Cct 19 Cct 20 Cct 21 Cct 22 Cct 23 Cct 24 Cct 25 Cct 26 Cct 27 ...

Страница 44: ...PX QX RX Version 4 20 User Manual Issue B 44 Number Description Location Cct 28 Cct 29 Cct 30 Cct 31 Cct 32 Cct 33 Cct 34 Users Areas Number Description 1 2 3 4 2 3 4 5 6 7 8 ...

Страница 45: ......

Страница 46: ...Guardall Limited Lochend Industrial Estate Newbridge Edinburgh EH28 8PL Tel 0131 333 2900 FAX 0131 333 4919 Technical Hotline 0131 333 3802 Part Number 320995 0B ...