PX Control Panel User Manual – Issue C
- 37
-
Holiday
Code-24
Feature
PX18
PX34
PX80
PX500
Max. Holidays
0
14
14
14
This option is used in conjunction with the programmable schedules. To program a holiday, select the
holiday option from the main menu followed by the holiday number. The holiday menu will then be
displayed.
Holiday
Options
Holiday-x
x=holiday number
Start-
DD:MM
DD:MM
End-
DD:MM
DD:MM
Set Group-1
1 – Max Set Groups
Note: The holiday date format is day and month only. No year is entered therefore the entered date will
remain programmed as a holiday for all subsequent years, or until it is removed from the holiday
schedule. It is not possible to program a holiday period that starts in December and ends in January. To
achieve this 2 holiday periods must be programmed.
Holiday Menu
Start
DD:MM
Enter the holiday start day and month. To disable a holiday enter a date of 00:00. The date entered must
be before the programmed end date.
Holiday Menu
End
DD:MM
Enter the holiday end day and month. To disable a holiday enter a date of 00:00. The date entered must
be after the programmed start date.
Holiday Menu
Set Group (Px80/500)
1 – Max Set Groups
A holiday can be programmed for a single set-group
Holiday Menu
Set Group 1-8 (Px34)
On/Off
If the Set Group option is on the holiday can be programmed any combination of set groups.
Intelligent Security & Fire Ltd