PX Control Panel User Manual – Issue C
- 33
-
Event log only messages
Log Text
Additional Data
Display Text
Event Description
230v Fault
NONE (see note)
NONE
Mains supply failed
230v OK
NONE (see note)
NONE
Mains supply restored
Active Circuit
Circuit
nnn
Cct
nnn
User selected active circuit test
Alarm (master shunt)
Circuit
nnn
Cct
nnn
Master shunt type circuit alarms
Alarm Abort
User
nn
, Keypad
m
Us
nn
, KP
m
Alarm abort signal transmitted.
Auto Check Fail
Circuit
nnn
Cct
nnn
A Circuit has failed to activate
during the auto check period.
Auto Check OK
NONE
NONE
Circuit Auto Check was OK
Bypass
User
nn
, Circuit
mmm
Us
nn
Cct
mmm
Circuit bypassed
Cannot set
User
nn
, Area
m
Us
nn
, A
m
User was not able to set an area
Cct Tested
Circuit
nnn
Cct
nnn
Circuit responded in walk test
Changed Code
User
nn
, Keypad
m
Us
nn
, KP
m
User changes own code
Changed Code
User
nn
, User
mm
Us
nn
, Us
mm
Manager or GSR user changes
code for another user
Changed Time
User
nn
, Keypad
m
Us
nn
, KP
m
Time modified, old time and new
time are logged
Check Fuse
n
N
Panel fuse number
Check Fuse
Conc
n
Conc
n
Concentrator fuse
Check Fuse
OPM
n
OPM
n
Output module fuse
Check Fuse
Door
n
Door
n
Access module fuse
Clear
Circuit
nnn
Cct
nnn
Master shunt type circuit clears
Code Clash
User
nn
, User
mm
Us
nn
, Us
mm
User has chosen a new code
which is the same as another
user
Comm Acknowledge
n
N
Central station acknowledge
alarm report
Comm Fail
n
N
Central station fails to
acknowledges alarm report
Comm Test
User
nn
, Keypad
m
Us
nn
, KP
m
User or the panel tested the
communicator(s)
Duress Alarm
User
nn
, Keypad
m
Us
nn
, KP
m
User enters a duress code
Engineer Reset
Circuit
nnn
Cct
nnn
Engineer reset type circuit
alarms
Entry Started
Circuit
nnn
Cct
nnn
Entry circuit opens
Failed Auto Set
User
nn
, Area
m
Us
nn
, A
m
Event programmer failed to auto
set due to circuits in alarm
Fault
Circuit
nnn
Cct
nnn
A Circuit short circuit when unset
or in alarm when trying to set
Fault
Keypad
n
KPn
Failed poll when unset
Fault
Conc nn
Conc nn
Failed poll when unset
Fault
OPM nn
OPM nn
Failed poll when unset
Fault
SM n
SM n
Failed poll when unset
Fault
Door nn
Door nn
Failed poll when unset
First code
User
nn
, Keypad
m
Us
nn
, KP
m
User entered code on Dual code
keypad
Head Count
Number
Number of activations of all
circuits programmed with the
head count option while the panel
was unset.
Isolate
User
nn
, Circuit
mmm
Us
nn
Cct
mmm
Circuit isolated by user
Isolate
User
nn
, Conc
m
Us
nn
,
m
Concentrator isolated by user
Key Set Req.
Circuit
nnn
Cct
nnn
Key type circuit alarms
Key Unset Req.
Circuit
nnn
Cct
nnn
Key type circuit clears