The system can be partitioned into a number of parts called set groups, each of which can be
individually set. The programmed user authority level must allow setting and the programmed user area
access will determine which set groups are available to a user.
Setting can be started by:
1. A user request on a keypad
2. A user activating a keyswitch
3. Automatically by a timer schedule
4. Remotely from a PC using the Guardall GuardStation software
5. A user request on an Access module Proximity Reader.
Setting modes include:
1. Instant, where setting is completed immediately
2. Timed, where setting is completed at the end of the programmed exit time
3. Exit point, where setting is completed by opening and closing the final exit circuit
4. Push button, where setting is completed by pushing the external PB circuits after opening and
closing the final exit circuit
Setting from a keypad
To set log on and select the set option.
02=Set
05=Eng
Press 02 to set.
If more than 1 authorised group is unset then the available groups will be displayed.
1=Workshop
2=Office
Choose the group to set.
Workshop
Setting
The setting message will be displayed
Workshop
Seconds Left-005
If timed setting is configured for the group the remaining exit time will be
displayed
Workshop
Set
When the groups set the set confirm message will be displayed.
If the
?
button is pressed while the set group menu is on display the set options will be displayed.
1=Silent Set
2=Quick Set
Choose silent set to set with no exit tone.
Choose quick set to ignore the programmed exit time and set instantly.
Keyswitch Setting
As an alternative to setting and unsetting from a keypad, your system may be fitted with an optional
keyswitch, which permits setting and unsetting of a group by operating a keyswitch. The keyswitch may
be configured for any set mode.