PX/QX
/RX
Version 4.20 User Manual – Issue B
- 39
-
Appendix E - Menu Restrictions
If a menu number is entered and the option is not available, then a reason will be displayed. For
example if no area is set and you select unset
the panel will prompt with the reason the unset option is
not available.
Not Available
No Set Area
This indicates that there is no set area available to the user.
There are many reasons why an option is not available. If you think an option should be available but
the prompt is not on display then enter the menu number and the panel will display an appropriate
message. The following table shows the reasons why a menu option is not available:
Not Available Message
Where Used
At Bypass Limit
User attempts to bypass a circuit when the number of bypassed circuits is
at the programmed bypass limit.
Call Engineer
User attempts to set when an engineer reset is required.
High Level Set
User attempts to unset a lower level group without unset higher levels
Isolate Limit
User attempts to isolate a circuit when the maximum allowed number of
circuits are already isolated
Isolated
User attempts to bypass a circuit that is isolated.
Key Not Used
The key (button) which has been pressed is never used in the current
menu.
Keypad Busy
User attempts to turn off a keypad that is being used.
Low Level Unset
User attempts to set a higher level group without setting lower levels
No Authority
User tries to select an option that is not allowed with their programmed
authority level.
No Set Area
User selects unset when all areas that can be unset from the keypad are
already unset.
No Unset Area
User selects set when all areas that can be set from the keypad are
already set.
Not Applicable
User attempts, for example, to reset when there are no alarms logged.
Not Programmed
The option selected is not programmed.
Option in Use
User selects an option, such as test, which is in being used by another
user.
Printer Busy
User attempts to print and the printer is in use.
Set Area
User attempts to access test when an area is set.
Shunt Limit
User attempts to shunt a circuit when the maximum allowed number of
circuits are already shunted
System Not Unset
User attempts to access an option that is only available when the system is
unset, for example the event log.
Test in Progress
User attempts to set an area that is being tested (on another keypad).
Test System
Circuit check fail has occurred and the user has selected set
Timer Control On
User attempts to log on outwith the schedule times.
Unset Area
User attempts to unset an unset area.