PX/QX
/RX
Version 4.20 User Manual – Issue B
- 35
-
Appendix C - Log Messages
Alarm & Event Log messages
Log Text
Additional Data
Display Text
Event Description
230v Fault
NONE (see note)
NONE
Mains supply failed
230v OK
NONE (see note)
NONE
Mains supply restored
A/Set Fault
Us
nn, Area m
Us
nn, Am
An area auto set with faults
Active Circuit
Circuit
nnn
Cct
nnn
User selected active circuit test
Alarm
Circuit
nnn
Cct
nnn
A Circuit alarm
Alarm (master shunt)
Circuit
nnn
Cct
nnn
Master shunt type circuit alarms
Alarm Abort
User
nn, Keypad m Usnn, KPm
Alarm abort signal transmitted.
Anti mask
Circuit
nnn
Cct
nnn
A Circuit program with the anti-
mask option has alarmed
Auth. Fail
User
nn
Us
nn
Encryption authentication fail
Auto Check Fail
Circuit
nnn
Cct
nnn
A Circuit has failed to activate
during the auto check period.
Auto Check OK
NONE
NONE
Circuit Auto Check was OK
Bat. Restore
NONE (see note)
NONE
The battery voltage is normal
after a battery low
Bat.Monitor Fail
NONE (see note)
NONE
Battery voltage is low or not
present during a battery test
Battery Low
NONE (see note)
NONE
The battery has reached the low
volts threshold (after a mains
fail)
Battery Low
Transmitter number
TXm
Transmitter battery low
Bypass
User
nn, Circuit mmm Usnn Cctmmm Circuit bypassed
Cannot set
User
nn, Area m
Us
nn, Am
User was not able to set an area
Cct Tested
Circuit
nnn
Cct
nnn
Circuit responded in walk test
Changed Code
User
nn, Keypad m Usnn, KPm
User changes own code
Changed Code
User
nn, User mm
Us
nn, Usmm
Manager or GSR user changes
code for another user
Changed Time
User
nn, Keypad m Usnn, KPm
Time modified, old time and new
time are logged
Check Fuse
n
N
Panel fuse number
Check Fuse
Conc
n
Conc
n
Concentrator fuse
Check Fuse
OPM
n
OPM
n
Output module fuse
Check Fuse
ACM
n
ACM
n
ACM fuse
Clear
Circuit
nnn
Cct
nnn
Master shunt type circuit clears
Clear
Circuit
nnn
Cct
nnn
A Circuit alarm has cleared.
Code Clash
User
nn, User mm
Us
nn, Usmm
User has chosen a new code
which is the same as another
user
Comm Acknowledge
n
N
Central station acknowledge
alarm report
Comm Fail
NONE
NONE
Control panel comm fail input
active.
Comm Fail
n
N
Central station fails to
acknowledges alarm report
Comm Fail
Module name
Module name
Module has reported a
communications fail
Comm Test
User
nn, Keypad m Usnn, KPm
User or the panel tested the
communicator(s)
Commission Fail
User
nn
Us
nn
Encryption commission fail
Commissioned
User
nn
Us
nn
Encryption commission OK
Data Route Fail
NONE
NONE
A call using the Dual comm data
route has failed.
Data Route OK
NONE
NONE
A call using the Dual comm data
route was successful.
Date Changed
Us
nn
Us
nn
Date changed (manual or auto)