EN
Problem
Cause
Help
Lock unlocks automatically
• Door contact defective
• Check door contact or wiring
(see point 5)
"Locked" signal does not
appear
• "Locked" relay contact is not
assigned.
• Check wiring
• Door contact defective
• Check door contact or wiring
(see point 5)
• The latch cannot move to the
locked position
• Align the door/striker; adapt
striker at latch / deadbolt
Daytime release cannot be
adjusted
• Seal not broken
• Break seal (see point 3.7)
• The signal at the control
input drops out
• Make sure the control unit is
sending a constant signal
• Latchbolt jammed,
lock moves 4x with 20 s rest
between each movement
• Actuate lock via profile
cylinder
• See point "Lock does not
unlock"
Relay contact „function
output“ is open
• Initial start-up or voltage loss
at lock
• Send control signal once
• Latchbolt triggered 4x with
door open
• Check door, lock and door
contact
NOTE
The function output is disabled when emergency power
backup B 5490 0301 is used!
Short-term release is not
responding
• The latchbolt must have been
in the "locked position" prior
to actuation of the locking
cylinder
• Actuate trigger lever or close
door
The lock locks more quickly /
slowly than required (hold-
open time too short / long)
• Hold-open time programmed
incorrectly
• Check/change programming
(see point 6)
Lock locks immediately
although hold-open time has
been set
• Door contact is closed
• Jumper missing
• Check door contact / open
door
• Check wiring (see point 5)
Programming not possible / is
not being saved
• Locking cylinder actuation
time too short
• Hold latchbolt for at least
5 s with the locking cylinder
retracted
• The lock does not switch to
programming mode
• Turn off daytime release
• Modified settings are not
saved
• Exit programming mode by
actuating the trigger lever at
the latchbolt