24
Stall Force Potentiometer
ALWAYS KEEP
SAFETY
AT THE TOP OF YOUR LIST WHEN ADJUSTING OR
SERVICING YOUR AUTOMATIC GATE OPENER!
1
2
3
4
O
N
D
IP
OFF
SOFT START OFF
WARNING OFF
OPEN PULL
SLV OPEN DLY.
MODE1 OFF
MODE2 OFF
ON
ON
PUSH
SIMULT.
ON
ON
120 MIN
AUTO CLOSE TIME
STALL FORCE
1
2
3
4
O
N
ON
ON
120 MIN
MAX
AUTO CLOSE TIME
STALL FORCE
MIN
MAX
STALL FORCE
IMPORTANT:
For safety reasons
the obstruction setting or
Stall
Force
on the GTO/PRO® 2000XL
control board comes from the facto-
ry set at
MIN
(minimum). In many
gate installations this setting will
need to be adjusted to overcome the
weight and size of the gates.
The
Stall Force
potentiometer on
the control board operates like a
volume control on a radio. It controls the obstruction
sensitivity (or the amount of force the opener will apply to an
obstruction) before it automatically stops and reverses direction for
approximately two (2) seconds.
Use a small slotted screwdriver to turn the arrow in the center of the
potentiometer. Adjust the stall force from the MINIMUM position
where the gate operates without obstructing from its own weight or the
wind conditions in your area.