23
Prison Mode Operation
(CLASS IV APPLICATIONS)
Prison mode operation means that constant pressure at the
close
or the
opeN
push button station
input is required to move the gate in the desired direction.
Follow these steps to toggle the prisoN MoDe operation on/off:
1.
Power down the unit.
2.
Press and hold the
opeN
and
close
push button while powering on the unit.
3.
The
prisoN MoDe leD
indicator will be on if operating in prison mode.
4.
Repeat the above steps to turn off prison mode operation.
Press and hold
at power up to toggle
to prison mode.
COM
COM
CYCLE
SAFETY
SHADOW
OPEN
CLOSE
STOP
OPEN
EDGE
CLOSE
EDGE
LIMIT ADJUSTMENTS
TEST SWITCHES
CLOSE
STOP
OPEN
GTO Inc. Tallahassee, FL
SX4000 Logic Board Rev. E
MIN
MAX
MIN
MAX
OFF
120
<<< JOG >>>
<<< >>>
SET
LIMIT
W1
CUT TO USE
3 BUTTON
STATION
C
O
M
C
O
M
AUTO CLOSE
TIMER
OPEN
CLOSE
OPEN
CLOSE
OPEN
CLOSE
STOP
W1
CUT TO USE
3 BUTTON
STATION
Wiring a 3-button station
CYCLE
SAFETY
OPEN EDGE
CLOSE EDGE
OPEN
CLOSE
STOP
COM
COM
COM
SHADOW
LOOP
OPEN
CLOSE
STOP
NOTE:
The W1 Jumper must be cut in order
to use a 3-button station.
To restore normal operation of cut jumper
you must connect a wire between the
stop
and
coM
terminals. This wire
functions the same as the W1 jumper.
COM
COM
COM
CYCLE
SAFETY
SHADOW
OPEN
CLOSE
STOP
OPEN
EDGE
CLOSE
EDGE
W1
CUT TO USE
3 BUTTON
STATION