21
Output Connections
Note:
• Maximum rating for all relay outputs are 24Vac/dc, 1 Amp.
• All relay outputs are dry contact (no voltage) switching.
• All outputs have corresponding LED indicator for diagnostic purposes. The corresponding LED
indicator will be lit when its relay is activated.
1.
closeD 1
and
closeD 2
:
At closed limit relay output.
• These two (2) terminals are shorted when gate is at the closed limit.
2.
ruN 1
and
ruN 2
:
Gate moving relay output.
• These two (2) terminals are shorted whenever the gate is moving/running.
3.
locK coM
and
locK N.o. / locK N.c.
:
Lock relay output
• This relay output is designed for use with either mechanical or mag-lock device. The relay is
activated (releasing the lock) during the first and the last 2-4 seconds of gate running.
example a:
Mag-Lock Connection: Use
locK coM
and
locK Nc
terminals. The diagram below is for a
typical mag-lock connection. Refer to the mag-lock manual for detailed operations.
example B:
For locks that are energized to release: Use
locK coM
and
locK No
terminals.
Lock Coil or Controller
24vDC Max, 1Amp Max
LOCK
RUNNING
CLOSED
LED11
LED10
LED09
REL
AY OUTPUT
S
LOCK N.C.
LOCK COM
LOCK N.O.
RUN 1
RUN 2
CLOSED 1
CLOSED 2
Example B
To positive (+) terminal of
Lock power supply
To negative (-) terminal of
Lock power supply
Mag Lock
24vDC Max, 1 Amp Max
LOCK
RUNNING
CLOSED
LED11
LED10
LED09
REL
AY OUTPUT
S
LOCK N.C.
LOCK COM
LOCK N.O.
RUN 1
RUN 2
CLOSED 1
CLOSED 2
To negative (-) terminal of
mag-lock power supply
To positive (+) terminal of
mag-lock power supply
Example A