13
Installing the Chain
NOTE:
All work on chain requires disconnecting AC power and batteries
!
1.
Make sure the operator power switch is
oFF
.
2.
Set
‘optioNs’ Dip
switch #1 to select the proper open direction of the gate.
3.
Set the operator power switch to the
‘oN’
position.
4.
Press and release the
‘opeN’
button on the board and allow the operator to run until the
‘at opeN liMit’ leD
is on. (Note: The
‘stall Force’
potentiometer may have to be
increased if the operator will not run).
5.
The
‘at opeN liMit’ leD
should be on when the operator reached the open limit and
stopped.
6.
Turn
oFF
operator power.
RED
WIRE
to positive (+)
JUMPER WIRE
(Supplied)
RED WIRE
to positive (+)
BLACK WIRE
to negative (–)
JUMPER WIRE
(Supplied)
negative (-) to positive (+)
BLACK
WIRE
to negative (–)
2.
Connect batteries to operator as shown. The red wire connects to the positive terminal
in the control box. The black wire connects to the negative terminal in the control
box. The jumper wire (included) connects both batteries together with the remaining
terminals. Wire the 24V system in series as shown below.
3.
Turn on AC power at this time.
NOTE:
Battery should be a 12 Vdc, U1,
230 Amp Minimum, Lead Acid Battery
(Typical Lawn and Tractor Battery).
NOTE:
When first turning operator power switch on, the unit may beep once