background image

O W N E R ’ S   M A N U A L

GP-SL100

Commercial Duty Slide Gate Operator

With Inherent UPS Battery Back-up System

GPSL100

    r

ev - 09/14/07

 

Pr

in

ted in China

This product meets and exceeds the requirements of UL 325 gate operator safety standards.

For more information on GTO/PRO’s full line of automatic gate openers and access controls visit our website at www.gtopro.com

LISTED

US

TWO 12VDC, U1, 230A BATTERIES ARE REQUIRED BUT NOT INCLUDED.

DO NOT Install This Operator Without Roller Guards, Safety Edges and Photo Beams!

APPROPRIATE ENTRY/EXIT DEVICES WILL BE REQUIRED - SEE YOUR DEALER.

Содержание GP-SL100

Страница 1: ...uirements of UL 325 gate operator safety standards For more information on GTO PRO s full line of automatic gate openers and access controls visit our website at www gtopro com LISTED US TWO 12VDC U1 230A BATTERIES ARE REQUIRED BUT NOT INCLUDED DO NOT Install This Operator Without Roller Guards Safety Edges and Photo Beams APPROPRIATE ENTRY EXIT DEVICES WILL BE REQUIRED SEE YOUR DEALER ...

Страница 2: ...ions not servicing the general public in which unauthorized access is prevented via supervision by security personnel The GP SL100 automatic gate operators are intended for use with vehicular slide gates The operators can be used in Class I II III and IV applications Converting Metric Units to English Equivalents When You Know Multiply By To Find Symbol centimeters 0 3937 inches in or meters 3 280...

Страница 3: ...Gate 9 Operator Installation Overview 9 Using the Mounting Template 10 Mounting Template not to scale 11 Removing the Operator Housing 12 Mounting the Operator 12 Connecting Power to the Operator 12 Installing the Chain 14 Control Board Description 15 Setting The Limits 16 Stall Force and Auto Close Adjustments 17 DIP Switch Settings 18 Input Connections 19 Accessory Terminal Connections 20 Output...

Страница 4: ...curity and safety This manual contains various safety precautions and warnings for the system designer installer and consumer Becausetherearemanypossibleapplicationsofthegateoperator thesafetyprecautionsandwarningscontained in this manual cannot be completely exhaustive in nature They do however provide an overview of the safe design installation and use of this product CAREFULLY READ AND FOLLOW A...

Страница 5: ...as access to it 2 Be careful with moving parts and avoid close proximity to areas where fingers or hands could be pinched 3 Determine the best obstruction sensing setting for this installation The gate MUST stop and reverse on contact with an obstruction After adjusting the force or the limit of travel retest the gate operator Failure to adjust and retest the gate operator properly can increase th...

Страница 6: ...slide gate system B Ahardwiredcontactsensorshallbelocatedanditswiringarrangedsothatthecommunicationbetween the sensor and the gate operator is not subjected to mechanical damage C A wireless contact sensor such as one that transmits radio frequency RF signals to the gate operator for entrapment protection functions shall be located where the transmission of the signals are not obstructed or impede...

Страница 7: ...ate operator unless you can see it and can determine that its area of travel is clear of people pets or other obstructions 8 If your gate has open rollers be sure that roller guards have been installed to prevent hands and fingers from being caught in the rollers see page 5 9 It is your responsibility to make sure that the installer posted warning signs on both sides of your gate If any of these s...

Страница 8: ...e Roller Guard Roller Guard Photo Beam Photo Beam Pedestrian Gate Moving Gate Can Cause Injury Or Death WARNING Vehicle Gate Operator Roller Guards Injuries occur when hands become caught betweenthegateandthe roller Roller guards and enclosed tracks must be installed to prevent this pinch point hazard Warning Signs Thewarningsigns withorangepanel must be installed on both sides of the gate 1 KEEP ...

Страница 9: ...ands and loose clothing may be dragged into chain sprockets Fingers and hands can be injured by rotating sprockets Keep hands fingers and loose clothing away from chain and chain opening in operator housing 1800 543 GATE 4283 www gtopro com Maximum Gate 1200 lb 544 3 kg 20 ft 6 1 m Voltage 110 Vac Frequency 60 Hz Power 300 W Class I II III and IV Vehicular Slide Gate Operator Serial Number XXXXXXX...

Страница 10: ...n Heavy duty steel frame rotomolded UV stabilized HDPE cover RB207 20 41 Chain 20ft 6 1m Operational Capacity Continuous duty operations Max rating 32 foot opening for 37 foot gate 1200 lbs Dual Gate compatible using two conductor 22 AWG shielded wire rated for direct burial Recommended Belden Wire 22 AWG type 8761 9461 9451 1266A or equivalent 1 pair shielded with drain wire Available at electric...

Страница 11: ... Warning Signs one for each side Owner s Manual Owner s Manual GTO PRO GP SL100 AC Powered Slide Gate Operators WARNING Ty Wraps 8 Hardware NOTE GTO receiver RB709U batteries 12vdc U1 230A minimum not included Must order separately 27 in 68 6 cm 23 in 60 3 cm 24 in 61 cm 19 in 50 2 cm 13 in 33 cm 17 in 42 cm 12 in 31 8 cm 18 in 46 cm 14 in 36 8 cm 12 in 31 8 cm 15 in 38 cm ...

Страница 12: ...a single slide gate installation with required safety features The operator must be installed on the inside of the gate You must install safety edges photo beams and roller guards not included to reduce the possibility of bodily injury SafetyEdges SafetyEdgesandPhotoBeams areRequired RollerGuard SafetyEdge REQUIRED RollerGuard REQUIRED SafetyEdge Use Rigid Conduit for inbound AC wire ChainBracket ...

Страница 13: ...the instructions on the template Before mounting the operator check the following The concrete pad is level 5 3 8 diameter mounting anchors are in their correct positions Conduit for power and accessory wiring is installed Roller Gate Fence Post Fence Post Roller Driveway SafetyEdges REQUIRED Safety Edge REQUIRED Safety Edge REQUIRED 4 in to 6 in Installation Alignment Chain Bracket Operator must ...

Страница 14: ... Template NOT TO SCALE 11 1 All conduit must be run through this area 9 13 16 9 13 16 5 1 8 Gate 5 1 8 3 15 16 3 15 16 4 6 Centerline of pad 5 Mounting holes 3 deep minimum Use wedge type anchors Chain centerline ...

Страница 15: ...The circuit must be protected with a 15 A main disconnect breaker not provided NOTE Power and wiring connections MUST be performed by a licensed electrician in accordance with NEC National Electric Code and local codes NEVER run low voltage e g accessory or receiver wires in conduit containing 115 Vac wiring Removing the Operator Housing Before you can gain access to the operator frame and its mou...

Страница 16: ...pen limit and stopped 6 Turn OFF operator power RED WIRE to positive BLACK WIRE to negative JUMPER WIRE Supplied negative to positive 2 Connect batteries to operator as shown The red wire connects to the positive terminal in the control box The black wire connects to the negative terminal in the control box The jumper wire included connects both batteries together with the remaining terminals Wire...

Страница 17: ...low 8 Insertachainadjusterbolt included ineachbracket Securechainadjusterboltusingthe 2 nuts included as shown Do not overtighten the nuts they will be used to adjust chain tension 9 Pull the gate to the desired open position 10 Attach chain to one chain adjuster bolt Use 41 chain with the GP SL100 11 Thread chain through chain sprockets Attach chain to second chain adjuster bolt Allow a minimum o...

Страница 18: ...OM SHADOW LOOP 1 2 3 9 10 11 12 13 14 20 21 19 17 15 18 4 5 6 7 8 16 COM 12V OPEN COM COM 12V OPEN COM COM 12V OPEN COM BLDC Motor Control Connection Limit Sensor Connection Alarm Buzzer Connection 12Vdc Accessory Power Dual Link Connection Relay Output To Control Lock Relay Output To Indicate Gate s Running Relay Output To Indicate Gate s Closed Logic Control Inputs LED Indicators For control inp...

Страница 19: ...OG buttons can be used to bring the gate to the precise closed position The JOG buttons will slowly run the gate when pressed and stop the gate when released 5 Once at the desired closed position press and hold the SET LIMIT button for 3 seconds or until the alarm sounds and STATUS LED is on At this time release the SET LIMIT button 6 Press and release the OPEN button on the logic board and allow ...

Страница 20: ... SET LIMIT CLOSED LED10 LED09 AUTO CLOSE TIMER MODE 1 MODE 2 OPEN DIR SLV OPN DUAL MODE LOW BATT ON ON SIMUL SLAVE SECURE OFF OFF DELAY MASTER SAFE CYCLE SAFETY OPEN EDGE RUN 2 OPEN CLOSE STOP COM COM COM SHADOW LOOP RELAY OUTPUTS LOCK N C LOCK COM LOCK N O RUN 1 RUN 2 CLOSED 1 CLOSED 2 1 2 3 4 ON CYCLE SAFETY SHADOW OPEN CLOSE STOP OPEN EDGE CLOSE EDGE STALL FORCE ADJUST LIMIT ADJUSTMENTS DIAG PO...

Страница 21: ...ault to single gate operation If DIP 3 is OFF Master OFF Slave gate will open after the master gate ON Slave gate will open simultaneously with the master gate DIP 3 MASTER SLAVE applicable to dual gate installation only NOTE This DIP switch is applicable if and only if all the following conditions are valid Dual Link cable is connected The second operator is detected by the master If the above co...

Страница 22: ...the gate is opening has no effect gate will continue to open Activation of this input while gate is idle will prevent gate from closing 6 OPEN Typically for use with exit loop or wand Activation of this input will open the gate if it s not already at the open position Activation of this input while at open limit will restart the auto close time if enabled 7 CLOSE Typically for use with 3 button co...

Страница 23: ...E STOP 3 Button Station GTO Photo Beams GTO Universal Receiver GTO Loop Detector Siren Activated Entry Device Cannot be mounted inside operator housing GTO Exit Wand Refer to Exit Wand manual for additional connections Edge Sensor ON 1 2 3 4 5 6 7 8 9 10 DIP NO COM NC V V LOOP LOOP LOOP NOTE Connections are for typical applications There may be additional connection options for applications that a...

Страница 24: ... The relay is activated releasing the lock during the first and the last 2 4 seconds of gate running Example A Mag Lock Connection Use LOCK COM and LOCK NC terminals The diagram below is for a typical mag lock connection Refer to the mag lock manual for detailed operations Example B For locks that are energized to release Use LOCK COM and LOCK NO terminals Lock Coil or Controller 24vDC Max 1Amp Ma...

Страница 25: ...accessories the accessories are protected by a poly fuse Disconnect accessories and allow poly fuse to cool down for 2 minutes before reconnecting 12Vdc 300 mA Power Supply ALARM STATUS DUAL LINK GTO LOOP DETECTORS EXIT SHADOW SAFETY AT OPEN LIMIT PRISON MODE ACC PWR 12VDC 300ma ACC POWER DUAL CABLE 12Vdc COM DUAL LINK LINK COM ...

Страница 26: ... COM CYCLE SAFETY SHADOW OPEN CLOSE STOP OPEN EDGE CLOSE EDGE LIMIT ADJUSTMENTS TEST SWITCHES CLOSE STOP OPEN GTO Inc Tallahassee FL SX4000 Logic Board Rev E MIN MAX MIN MAX OFF 120 JOG SET LIMIT W1 CUT TO USE 3 BUTTON STATION COM COM AUTO CLOSE TIMER OPEN CLOSE OPEN CLOSE OPEN CLOSE STOP W1 CUT TO USE 3 BUTTON STATION Wiring a 3 button station CYCLE SAFETY OPEN EDGE CLOSE EDGE OPEN CLOSE STOP COM...

Страница 27: ...ly aligned and not kinked or binding along its path of travel The installation is complete Test the operator accessories and safety devices for correct function Read and fill out the INSTALLATION CHECKLIST on the back cover of this manual 1 Lower the operator housing into position over the operator Allen Bolts with 5mm key Washers 2 Pull sides out slightly so that the housing sits into place prope...

Страница 28: ...al Gate Link Connection Installing a Dual Gate Operator System IMPORTANT With a dual gate system certain control board settings and connections are required on the MASTER unit only and some are required on both the MASTER and the SLAVE unit The list below gives an overview Gate Sequencing DIP 2 on Master Unit Alarms wired to MASTER only Entry Devices can be wired to either unit Adjustable Auto Clo...

Страница 29: ...MODE 1 MODE 2 OPEN DIR SLV OPN DUAL MODE LOW BATT ON ON SIMUL SLAVE SECURE OFF OFF DELAY MASTER SAFE Master DIP Switch Settings Slave DIP Switch Settings IMPORTANT The 2 Switch Settings are set on the MASTER Operator only If DIP 3 is set to slave ON DIP 2 and 4 are dictated by MASTER DIP settings DIP 3 ON SLAVE mode used for SLAVE operator only OFF MASTER mode used for MASTER operator only DIP 4 O...

Страница 30: ...valent 1 pair shielded with drain wire Available at your local electrical supply store Safety Edges and Photo Beams are Required Chain Chain Use Rigid Conduit for AC power Use Rigid Conduit for AC power Operator Operator Photo Beams R4222 NOT INCLUDED NOTE A separate gate or entrance must be installed for pedestrian use Not shown here Overview of a Dual Gate Operator InstallationThe diagram below ...

Страница 31: ...age 17 Oil and adjust the chain when necessary Check for wear on all moving parts and tighten bolts as necessary Check the gearbox for any sign of oil leakage If the gearbox is leaking call the GTO Service Department for assistance Check rollers or hinges on the gate and lubricate if needed Check for loose or corroded wires Make sure the warning signs roller guards fence screen etc see page 5 are ...

Страница 32: ...d the battery voltage has reached 26 vdc GFI Circuit Breaker Connections in the Field Wiring Connection Compartment Battery Connections Battery Voltage Load Test Battery 1 beep with 2 seconds pause The revolution counter circuit board is not being detected Check Connections for Limit Sensors on Logic Board 2 beeps with 2 seconds pause The logic board does not detect the motor drive board connectio...

Страница 33: ... is shorted Check terminal voltage with respect to Com to ensure you read 12 vdc Shadow LED ON brightly Status Light flashes Shadow terminal shorted to Com Photo beam or loop detector is sensing a presence Relay on photo beam or loop detector is shorted or latched Wire between photo beam or loop detector and shadow terminal is shorted Check terminal voltage with respect to Com to ensure you read 1...

Страница 34: ...and Loop detector Photo beam etc is shorted or latched Wire from Exit wand Loop detector Photo beam etc is shorted Check terminal voltage with respect to Com to ensure you read 12 vdc Close LED ON brightly Status Light flashes Close terminal shorted to Com Push button is stuck Check terminal voltage with respect to Com to ensure you read 12 vdc Stop LED ON brightly Status Light flashes Stop and Co...

Страница 35: ...copies of receipts or other proof of purchase Please retain these records After the warranty period GTO or one of its authorized service centers will make any necessary repairs for a nominal fee Call GTO at 850 575 0176 for more information GTO MAKES NO OTHER WARRANTIES OR REPRESENTATIONS OF ANY KIND WHATSOEVER EXPRESSED OR IMPLIED AND ALL IMPLIED WARRANTIES INCLUDING ANY WARRANTY OF MERCHANTABILI...

Страница 36: ...s and labels were installed as specified in the IMPORTANT SAFETY INSTRUCTIONS ____ Safety instructions were reviewed with the customer ____ The IMPORTANT SAFETY INSTRUCTIONS manual was given to the customer ____ Customer was instructed about proper use of the chain release pins ____ Customer was asked to fill out customer support card and mail it to GTO Inc ____ Customer was asked to retain all re...