GTO 2002XLS Instruction Manual © 01.12.12
17
SURGE PROTECTOR
Transformer
Set the CLOSED Position Limit
for PULL-TO-OPEN Installation
Your transmitter must be able to operate the gate. If not, see "Personal Transmitter Setting" on page 19.
Note: The OPEN limit is when the openers are fully retracted and the gates are in the fully open position.
The open limit setting can only be adjusted by moving the gate brackets. To achieve the optimum closed
position, you must adjust the CLOSED limit setting:
Step 1
Make sure the Control Box is ON and that
the gates are in the OPEN POSITION (arm
fully retracted).
Step 2
Press and HOLD the Second Opener
CLOSE button on the control board and be
prepared to RELEASE the button when the
gate reaches the desired closed position/
limit. Use the JOG OPEN and CLOSE
buttons to "fine tune" the gate position if
neccessary.
Step 3
Press and HOLD the First Opener CLOSE button on the control board and be prepared to RELEASE the
button when the gate reaches the desired closed position/limit. Use the JOG OPEN and CLOSE buttons to
“fine tune” the gate position if neccessary.
Step 4
With the gates in in the desired closed positions PRESS and HOLD the SET LIMIT button until the alarm
and RED Light come on. Then release the button.
NOTE: The opener must be extended more than 7 inches to set limits.
Step 5
NOTE: When the control box cover is removed the receiver range is reduced to less than 5 feet.
Press the transmitter button once (within 5 feet of the control board) and allow the gates to fully open.
The alarm will beep once when the gates reach the OPEN LIMIT. This indicates the limits for the arms
are programmed in memory.
Step 6
Press the transmitter button and allow the gates to fully close to verify that it stops at the desired positions.
Repeat Steps 2-5 if correction is needed.
Step 7
Plug the transformer into the electrical outlet. Use of a surge
protector with the transformer is
strongly recommended. If
electrical outlet is located outdoors, outlet and transformer
should be protected by a weatherproof cover.
MIN
MAX OFF
REMOVE JUMPER FOR
PUSH TO OPEN OPTION
120
SEC.
STALL FORCE
OPEN < JOG > CLOSE
PWR.
SET
LIMIT
1st OPR.
2nd OPR.
STATUS
AUTO CLOSE
FIRST Opener
JOG Buttons
SECOND Opener
JOG Buttons
SET LIMIT Button
SET LIMIT Light