manualshive.com logo in svg
background image

WARNING!

This equipment is similar to other gate or door equipment and meets or exceeds 

Underwriters Laboratory Standard 325 (UL 325). However, gate equipment has 

hazards associated with its use and therefore by installing this product the installer 

and user accept full responsibility for following and noting the installation and safety 

instructions. Failure to follow installation and safety instructions can result in hazards 

developing due to improper assembly. You agree to properly install this product and 

that if you fail to do so Gates That Open, LLC, (“GTO”) shall in no event be liable for 

direct, indirect, incidental, special or consequential damages or loss of profits whether 

based in contract tort or any other legal theory during the course of the warranty 

or at any time thereafter. The installer and/or user agree to assume responsibility 

for all liability and use of this product releasing Gates That Open, LLC, from any and 

all liability. If you are not in agreement with this disclaimer or do not feel capable of 

properly following all installation and safety instructions you may return this product 

for full replacement value.
READ ALL INSTRUCTIONS CAREFULLY AND COMPLETELY before attempting to 

install and use this automatic gate operator. This gate operator produces a high level  

of force. Stay clear of the unit while it is operating and exercise caution at all times.
All automatic gate operators are intended for use on 

vehicular gates only.

This product meets and exceeds the requirements of UL 325, the standard which 

regulates gate operator safety, as established and made effective March 1, 2000, by 

Underwriters Laboratories Inc.

For more information on the GTO/ACCESS SYSTEMS full line of automatic gate 

operators and access controls visit our website at www.gtoaccess.com.

©2011 Gates That Open, LLC 

Printed in China for Gates That Open, LLC.

 

R4728 01.12.12

, LLC

®

DUAL Gate Operator System

Installation Manual

2002XLS

2002XLS

PROFESSIONAL RESIDENTIAL

ACCESS

SYSTEMS

PROFESSIONAL INSTALLATION RECOMMENDED!

Содержание 2002XLS

Страница 1: ...at Open LLC from any and all liability If you are not in agreement with this disclaimer or do not feel capable of properly following all installation and safety instructions you may return this produc...

Страница 2: ...Restricted Access Vehicular Gate Operator Class IV A vehicular gate operator or system intended for use in a guarded industrial location or building such as an airport security area or other restrict...

Страница 3: ...ly 8 Check Clearance 9 Install Gate Bracket 10 Attach Operator Arm 10 Installation of Closed Position Stops 11 Mount the Battery Box Control Box 13 Connect the Battery Box Control Box 14 Connect Opera...

Страница 4: ...justable stall force This safety feature makes the gate stop and reverse direction within two seconds when it comes in contact with an obstruction The MIN setting means the gate will exert the minimum...

Страница 5: ...ed installed and maintained automated gate operator systems Keep in mind that the gate operator is just one component of the total gate operating system Each component must work in unison to provide t...

Страница 6: ...per for the type and size of gate its frequency of use and the proper class rating 2 Make sure the gate has been properly installed and swings freely in both directions Repair or replace all worn or d...

Страница 7: ...ea Driveway 10 10 10 10 10 10 NEVER INSTALL any control device within gray area III After Installation 1 Attach the warning signs included to each side of the gate to alert the public of auto matic ga...

Страница 8: ...by contacting Gates That Open LLC at 3121 Hartsfield Road Tallahassee Florida 32303 or by calling 1 800 543 4283 and requesting a duplicate copy One will be provided to you free of charge Required Saf...

Страница 9: ...ate system B A hard wired contact sensor shall be located and its wiring arranged so that the communication between the sensor and the gate operator is not subjected to mechanical damage C A wireless...

Страница 10: ...rians must use separate entrance WARNING MOVING GATE Can Cause Injury or Death 1 800 543 GATE 4283 www gtoaccess com 2002XLS PROFESSIONAL RESIDENTIAL 9901178 TO MANUALLY OPEN AND CLOSE THE GATE 1 Turn...

Страница 11: ...pull tube fully retracted is 33 3 4 mounting point to mounting point arm stroke 15 max Minimum gate length is 5 ft Adjustable auto close 3 to 120 seconds and stall force potentiometers Power terminal...

Страница 12: ...er source you will need to use at least 5 watts solar charging power to charge the battery FM122 Refer to the Solar Panel and Gate Activity chart below All low voltage wire used with the GTO Gate Oper...

Страница 13: ...tal Cross Member Vertical Cross Member Your Property Your Property Pull To Open arm retracts to open Push To Open arm extends to open 3 Prepare the Gate The gate must be plumb level and swing freely o...

Страница 14: ...ENER Gate Bracket 2 Post Pivot Bracket 2 Post Bracket 4 Closed Position Stop Plate 2 Hairpin Clip 4 5 16 x 1 3 4 Bolt 2 3 8 x 2 Bolt 2 3 8 x 2 3 4 Bolt 4 3 8 x 8 Bolt 8 8 Nylon Cable Tie 28 3 8 Washer...

Страница 15: ...e post bracket Page 9 Depending upon the diameter of the post you may need longer bolts than those provided Bolts should be at least 1 longer than the diameter of the post Page 9 Metal plate for woode...

Страница 16: ...positions Horizontal Cross Member Gate Swings Evenly and Freely Hung Firmly and Plumb Post Bracket Assembly Control Box Battery Box Gate Bracket Master Gate Opener Fence Post Set in Concrete Run 1000...

Страница 17: ...nd washers out of the wood The post pivot bracket may not be necessary on posts larger than 6 in diameter see page 6 Fence posts smaller than 6 in diameter or 6 square should be made of metal instead...

Страница 18: ...et will have to be adjusted later 3 8 x 2 Bolt 3 8 Nut Post Pivot Bracket Post Bracket Post Bracket 3 8 Lock Washer 3 8 Washer Step 2 Attach post bracket assembly to the rear mount of the opener with...

Страница 19: ...t binding at the post pivot bracket If you don t have the required clearance or if the gate opener is binding on the post pivot bracket remove the 5 16 x 1 3 4 bolt and readjust the post pivot bracket...

Страница 20: ...late Created for Decorative Gate required but not supplied Remove excess bolt length with hacksaw or bolt cutters FRONT VIEW SIDE VIEW FRONT VIEW SIDE VIEW Round Metal Post Round Wood Post Square Meta...

Страница 21: ...nd gate opener on the opposite side of the driveway from the control box will be referred to as the SECOND gate and gate opener Illustration A Closed Position Stop Plate mounted horizontally on metal...

Страница 22: ...e the closed position stop plate toward the ground stop until they touch Illustration C Once you have moved the stop plate to the correct position tighten its hardware completely NOTE For a push to op...

Страница 23: ...eration is subject to the following conditions 1 This device may not cause harmful interference 2 This device must accept an interference that may cause undesired operation Transmitter distance may va...

Страница 24: ...Step 5 Tuck the excess battery leads into the battery box and reattach the CONTROL BOX to the BATTERY BOX Step 6 Remove the Control Box Cover Remove the four 4 control box cover screws and remove the...

Страница 25: ...trol board to the battery at distances up to 1000 DO NOT use telephone wire or solid wire NEVER SPLICE WIRES Splicing permits corrosion and seriously degrades the wire s ability to carry an adequate c...

Страница 26: ...ee F L R4722 STALL FORCE OPEN JOG CLOSE PWR SET LIMIT 1st OPR 2nd OPR STATUS AUTO CLOSE SFTY EXIT CYCLE EDGE SENSOR COMMON LOCK LOCK WHT GRN RED BLK WHT GRN SECOND OPR FIRST OPR RED BLK 14 VAC OR SOLA...

Страница 27: ...and CLOSE buttons to fine tune the gate position if neccessary Step 4 With the gates in in the desired closed positions PRESS and HOLD the SET LIMIT button until the alarm and RED Light come on Then...

Страница 28: ...Set Auto Close Time The Auto Close determines how long the gate will remain open before it automatically closes The factory setting is OFF Use a small flat blade screwdriver you can adjust the setting...

Страница 29: ...5 feet FCC WARNING Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment In accordance with FCC...

Страница 30: ...to open the gate and it fully retracts to close the gate C 2 You will install the operator while the gate is in the CLOSED POSITION arm fully retracted A 3 You must use the Push to Open Post Pivot Bra...

Страница 31: ...on when the gate reaches the desired open position limit Use the JOG OPEN and CLOSE buttons to fine tune the gate position if neccessary C Press and HOLD the SECOND Opener OPEN button on the control b...

Страница 32: ...inal Insert the other solar panel wire into the remaining 14VAC OR SOLAR terminal The wires can be connected to the 14VAC OR SOLAR terminals regardless of color polarity Step 4 Tighten set screws agai...

Страница 33: ...VAR6 K1 PF1 K2 BATT BATT K3 K4 VAR4 VAR3 VAR2 VAR1 MIN MAX OFF JP1 REMOVE JUMPER FOR PUSH TO OPEN OPTION 120 SEC GTO Inc Ta l l a h a s s e e F L R4722 STALL FORCE OPEN JOG CLOSE PWR SET LIMIT 1st OPR...

Страница 34: ...the operation as follows OPEN STOP CLOSE STOP OPEN 4 EDGE SENSOR Typically for use with contact edge sensor Activation of this input while gate is moving will cause it to reverse direction for 2 secon...

Страница 35: ...between the operator mounting brackets and masonry surface for additional strength B If a push to open installation is impossible due to traffic hazards terrain etc another option is to re hang the g...

Страница 36: ...the transmitter button will shut off the alarm c Rapid beeping Unit has encountered two 2 obstructions without reaching either limit Power cycle to reset the alarm Transmitter will not operate the gat...

Страница 37: ...________________ 13 8 to 14 8 Vdc Measure voltage at battery terminals with battery disconnected Gate and Opener Maintenance 1 Keep gates properly maintained Grease hinges Make sure gates remain level...

Страница 38: ...uired to send in your original equipment for repair Please refer to Manufactures Limited Warranty for complete details Securely pack the component s authorized for return to the factory Include a copy...

Страница 39: ...RB741 RB742 RB743 Purchase an additional transmitter for each vehicle in your family The Two Button Transmitter can be programmed to operate both your gate operator and a garage door opener using the...

Страница 40: ...vehicle exits the property 100 ft range between transmitter and receiver Easy installation LOCKING SECURITY ACCESSORIES Automatic Gate Lock FM144 The 1 Accessory For Swing Gate Operators Designed for...

Страница 41: ...rd 14 volt 1430 mA AC transformer included with the 2002XLS to maintain battery charge Gate Grounding Kit R4196 The purpose of the grounding kit is to REDUCE THE RISK of damage to electronic equipment...

Страница 42: ...32 GTO 2002XLS Instruction Manual 01 12 12 Notes...

Страница 43: ...GTO 2002XLS Instruction Manual 01 12 12 33 Notes...

Страница 44: ...3121 Hartsfield Road Tallahassee Florida USA 32303 850 575 0176 Fax 850 575 8912 Web site www gtoaccess com 24 7 Troubleshooting Wizard http support gtoinc com PROFESSIONAL RESIDENTIAL ACCESS SYSTEMS...

Отзывы: