TRANSMITTING MEASURED DATA COBOSAFE-CBSF
36
CoboSafe-CBSF
325-2810-012US15
12 Transmitting Measured Data CoboSafe-CBSF
The force measurements performed are stored and indexed in the CoboSafe-CBSF. The record
receives the following information:
■
Date
■
Time
■
Measurement number
■
Device type
■
Damping element K1 used
■
Ambient temperature during measurement
■
Humidity during measurement
The data can be transferred wirelessly to CoboSafe-Vision or via USB cable. For more informa-
tion, please refer to the „CoboSafe-Vision Operating Manual “.
12.1 Transmitting Measured Data CoboSafe-CBSF
-Basic
The data set stored by CBSF-Basic contains only the measurement number and no additional
data. Supplementary parameters are defined when importing into the CoboSafe-Vision soft-
ware.
12.2 Wireless Data Transmission
To be able to transmit data wirelessly, wire transmission has to be activated by selecting “ON”
in the wireless menu. Read to chapter “Menu Navigation” to learn about this.
The range of wireless transmission is about 20 meters under normal conditions. It may be
restricted by external factors. If transmission is restricted or not possible at all, use a USB cable
for transmission.
Not with CoboSafe-CBSF-Basic!
12.3 Transmission via USB Port
Use the included USB cable to transfer the data. Plug the cable into the Micro-USB connection
socket of the CoboSafe-CBSF and into the USB socket of the PC. For more information on data
transmission, refer to the „CoboSafe-Vision Operating Manual “.
Only a shielded USB cable approved by the manufacturer may be used to connect
the CBSF to the PC.