background image

 

GTD-440P II BSW User Manual 

33 

 

Other features 

 

Eco-friendly design: equipped with intelligent tracking system to decrease the power of lamp source. 

 

Power setting: built-in continuous rechargeable battery, allowing setting functional data via LCD interface without 

power connection   

 

Sleep mode: uses the most advanced technology to remotely activate sleep mode. When the lamp is disconnected 
from signal, the sleep mode is enabled automatically to make it more stable and safer. Sleep time can be customized. 

 

Communication design: DMX wired or wireless signal transmission, RDM bi-directional control technology, can be 

upgraded by DMX remote software. 

Cleaning and maintenance 

It is required that the fixture should be kept clean and well maintained to ensure its reliability. Its lifespan mainly depends 
on the working environment and proper operation. Should you have any questions, please consult a technical engineer of 

GTD Lighting.   

Notes 

Damage resulted from dust, smoke, oil or improper use is not covered by warranty.   

Warning 

Disconnect the fixture from AC power, and let it cool down for at least 15 minutes before opening the housing. Make sure 
to use a soft cloth to clean the optical components, and be careful, as the coating is easily scratched. Do not use any organic 
solvent such as alcohol to clean the reflector mirror, dichroic color filters or housing of the fixture. 

 

If the lens is cracked or otherwise damaged, replace it immediately.   

 

If the lamp becomes damaged or deformed in any way it must be replaced. 

 

If the light from the lamp appears dim, this normally indicates that it is reaching the end of its life span and should 
be changed at once. Aged lamps run to the extremity of their life might explode. 

 

  If  fixture  does  not  function,  check  the  fuse  on  the  power  socket  of  the  fixture.  Replace  the  fuse  of  the  same 
specification if it is blown. 

 

The fixture is equipped with thermal-protection device that will switch off the lamp in case of overheating. If this 

GTD-440P II BSW (SPOT) 

Содержание 440P II BSW

Страница 1: ...Moving Head beam spot wash GTD 440P II BSW User s Manual Guangzhou GTD Lighting Technology Co Ltd Tel 86 20 61808296 Fax 86 20 61812282 http www gtd lighting com ...

Страница 2: ...ompanies and are hereby acknowledged All non GTD brands and product names are trademarks or registered trademarks of their respective companies GTD and all affiliated companies hereby disclaim any and all liabilities for property equipment building and electrical damages injuries to any persons and direct or indirect economic loss associated with the use or reliance of any information contained wi...

Страница 3: ...ion 7 Clamps installation 7 Device installation 7 Lamp fitting and adjustment 8 Power Control connection 9 Power connection 9 Control connection 9 Testing 9 Control panel 10 Gobos and colors 10 Gobo specification 10 Gobos 11 Colors 11 Menu structure 12 DMX protocol 15 Technical specification 30 Cleaning and maintenance 334 Troubleshooting 35 System wiring diagram 36 Spare parts list 37 Appendix 1 ...

Страница 4: ...sential that the fixture is properly grounded Only qualified personnel should perform electrical connections WARNING Wear protective eyewear Never look directly into the light source Do not direct lens to sun ray or strong light Only qualified and certified personnel should perform installation of this fixture and only the original rigging parts brackets included with this fixture should be used f...

Страница 5: ...ixture Disconnect the fixture from power before changing any parts or accessories Make sure that the installation area can hold a minimum point load of 10 times the weight of all installed fixtures clamps cables auxiliary equipment etc Check that the cover clamps and locks are undamaged Certified safety cables must always be used when installing the fixture The fixture is only intended for install...

Страница 6: ...kaging foam which contains both the fixture and its accessories Remove the foam from the top put away the accessories and then take out the fixture wrapped in the plastic bag Notes Check if the pan is unlocked before connecting the fixture to power Packing after use 1 Switch off the fixture and wait for at least 5 minutes before disconnecting it from AC power Cool down the fixture for at least 15 ...

Страница 7: ...el Three core waterproof signal extension cable Male 1 set 0 5m with three pin card faucet female Three core waterproof signal extension cable female 1 set 0 5m with three pin card faucet male Notes Accessories are subject to change without any prior written notice Product introduction 1 Head 2 Focus 3 Gobo color wheel assembly 4 Light source 5 Pan 6 Base 7 MENU UP DOWN ENTER button 8 Display 9 Pr...

Страница 8: ...he safety cable which goes through the mounting hole on the base Do not attach the safety cable on the handle Device installation Note The lamp is heavy suggest to lay flat no suggest to hang no side hanging 1 Make sure there is no damage on the clamps or safety cables before installation 2 The clamp is mounted on the chassis of the fixture Horizontally insert the clamp into the mounting holes of ...

Страница 9: ...l 4 Make sure the new bulb is installed in the right position on the holder and the mounting holes are fixed and the midline of the lamp is aligned with the center point of the effect assembly consisting of the rotating gobo wheel static gobo wheel color wheel strobe prism and frost focus module and object lens Notes The fixture uses OSRAM SIRIUS HRI 440W S featuring low power consumption and high...

Страница 10: ... data input and output 3 pin optional as shown below Connection between the console and fixture and between fixtures must be made with 2 core screened DMX signal cable Maximum connecting distance of signal cable is 150 meters Additional DMX512 signal amplifier is recommended for longer distance Connect the Console s DMX OUTPUT to the first fixture s DMX INPUT then the first fixture s DMX OUTPUT to...

Страница 11: ...P or DOWN to change the value of the selected function increase or decrease Press MENU to return to the previous menu or exit LED indicators Power on RED power LED indicator on Signal on Green DMX indicator on No Signal Green DMX indicator off Gobos and colors Gobo specification All patterns are made onto the metal or glass gobos and can be customized according to user s requirement The customized...

Страница 12: ...ariable speed One fixed gobo wheel 14 gobos open CW CCW rotation variable speed Rotating gobo wheel Fixed gobo wheel Colors One color wheel 12 colors open split color CW CCW rotation variable speed 1 red 2 yellow 3 blue 4 light green 5 light pink 6 light yellow 7 cyan 8 green 9 magenta 10 CTO 1 11 CTB 1 12 UV purple ...

Страница 13: ...GTD 440P II BSW User Manual 12 CMY CTO color temperature correction wheel ...

Страница 14: ...re Software Version X X The software version Lamp Control Lamp On Off Power On Lamp On Console Lamp On Console Lamp Off Lamp On Temp Lamp Off Temp On Off Enable Disable Enable Disable Enable Disable 20 79 45 C 68 174 113 F 80 139 130 C 176 282 266 F Open lamp Power on open lamp Console open lamp Console close lamp Open lamp below temperature Close lamp above temperature System Setting Status Setti...

Страница 15: ...m Mode 1 Custom Mode 2 Custom Mode 3 Standard channel mode Simplified channel mode Extended channel mode Custom channel mode 1 Custom channel mode 2 Custom channel mode 3 Set Custom Mode1 Set Custom Mode2 Set Custom Mode3 Max Channel Pan Channel XX Pan CH01 Change the channel order Program Edit Select Prog Program Unit 1 Program Unit 2 Program Unit 3 Program 1 10 Program 1 10 Program 1 10 Choose b...

Страница 16: ...en 160 223 62 7 87 5 Random strobe from slow to fast 224 255 87 8 100 0 Open 2 Intensity 0 255 0 0 100 0 No light è Full light 0 0 3 Cyan 0 255 0 0 100 0 White è Full cyan 0 0 4 Magenta 0 255 0 0 100 0 White è Full magenta 0 0 5 Yellow 0 255 0 0 100 0 White è Full yellow 0 0 6 CMY color macro 0 15 0 0 5 9 CMY color macro off 0 0 16 135 6 3 52 9 CMY synchronous color from slow to fast 136 255 53 3 ...

Страница 17: ...3 7 76 5 Stop 196 255 76 9 100 0 Color1 continous rotation CCW from slow to fast 9 Reserved 0 255 100 0 100 0 Reserved 0 0 10 Gobo wheel static 0 8 0 0 3 1 Open gobo 0 0 9 10 3 5 3 9 Gobo 1 11 12 4 3 4 7 Gobo 2 13 14 5 1 5 5 Gobo 3 15 16 5 9 6 3 Gobo 4 17 18 6 7 7 1 Gobo 5 19 20 7 5 7 8 Gobo 6 21 22 8 2 8 6 Gobo 7 23 24 9 0 9 4 Gobo 8 25 26 9 8 10 2 Gobo 9 27 28 10 6 11 0 Gobo 10 29 30 11 4 11 8 G...

Страница 18: ... 12 shake 109 114 42 7 44 7 Gobo 13 shake 115 127 45 1 49 8 Gobo 14 shake 128 187 50 2 73 3 Gobo wheel continous rotation CW from slow to fast 188 195 73 7 76 5 Stop 196 255 76 9 100 0 Gobo wheel continous rotation CCW from slow to fast 11 Rotating gobo wheel 0 7 0 0 2 7 Open gobo 0 0 8 12 3 1 4 7 Gobo 1 13 17 5 1 6 7 Gobo 2 18 22 7 1 8 6 Gobo 3 23 27 9 0 10 6 Gobo 4 28 32 11 0 12 5 Gobo 5 33 37 1...

Страница 19: ... wheel 2 0 127 0 0 49 8 Gobo rotation positioning 128 187 50 2 73 3 Gobo continous rotation CW from slow to fast 188 195 73 7 76 5 Stop 196 255 76 9 100 0 Gobo continous rotation CCW from slow to fast 13 0 65535 0 0 100 0 Gobo rotation positioning fine LSB 14 Focus 0 255 0 0 100 0 Near è Far 0 0 15 Zoom 0 255 0 0 100 0 Narrow è Wide 0 0 16 Prism1 0 31 0 0 12 2 Off 0 0 32 255 12 5 100 0 On 17 Prism...

Страница 20: ... 100 0 Pan 0 0 22 0 65535 0 0 100 0 Pan fine LSB 23 Tilt 0 255 0 0 100 0 Tilt 46 18 0 24 0 65535 0 0 100 0 Tilt fine LSB 25 Scan speed 0 255 0 0 100 0 Scan speed from fast to slow 0 0 26 Special controls 0 9 0 0 3 5 No function 0 0 10 19 3 9 7 5 Open light after 5 seconds 20 29 7 8 11 4 Close light after 5 seconds 30 39 11 8 15 3 Color wheel half color switch 40 59 15 7 23 1 Reserved 60 69 23 5 27...

Страница 21: ...7 190 199 74 5 78 0 Built in program 8 200 209 78 4 82 0 Built in program 9 210 219 82 4 85 9 Built in program 10 220 255 86 3 100 0 Reserved DMX protocol Simplified 16channels Revision A Valid from firmware version 1 0 DMX mode Name DMX value DMX percentage Function Default DMX Value Simplified 23ch 1 Strobe Shutter 0 31 0 0 12 2 Closed 0 0 32 63 12 5 24 7 Open 64 127 25 1 49 8 Synchronous strobe...

Страница 22: ...pen 0 0 10 19 3 9 7 5 Color 1 20 29 7 8 11 4 Color 2 30 39 11 8 15 3 Color 3 40 49 15 7 19 2 Color 4 50 59 19 6 23 1 Color 5 60 69 23 5 27 1 Color 6 70 79 27 5 31 0 Color 7 80 89 31 4 34 9 Color 8 90 99 35 3 38 8 Color 9 100 109 39 2 42 7 Color 10 110 119 43 1 46 7 Color 11 120 127 47 1 49 8 Color 12 128 187 50 2 73 3 Color1 continous rotation CW from fast to slow 188 195 73 7 76 5 Stop 196 255 76...

Страница 23: ...bo 1 shake 43 48 16 9 18 8 Gobo 2 shake 49 54 19 2 21 2 Gobo 3 shake 55 60 21 6 23 5 Gobo 4 shake 61 66 23 9 25 9 Gobo 5 shake 67 72 26 3 28 2 Gobo 6 shake 73 78 28 6 30 6 Gobo 7 shake 79 84 31 0 32 9 Gobo 8 shake 85 90 33 3 35 3 Gobo 9 shake 91 96 35 7 37 6 Gobo 10 shake 97 102 38 0 40 0 Gobo 11 shake 103 108 40 4 42 4 Gobo 12 shake 109 114 42 7 44 7 Gobo 13 shake 115 127 45 1 49 8 Gobo 14 shake ...

Страница 24: ...7 34 5 38 0 Gobo 5 shake 98 107 38 4 42 0 Gobo 6 shake 108 117 42 4 45 9 Gobo 7 shake 118 127 46 3 49 8 Gobo 8 shake 128 187 50 2 73 3 Gobo wheel continous rotation CW from slow to fast 188 195 73 7 76 5 Stop 196 255 76 9 100 0 Gobo wheel continous rotation CCW from slow to fast 0 0 12 Gobo rotating positionin g gobo wheel 2 0 127 0 0 49 8 Gobo rotation positioning 128 187 50 2 73 3 Gobo continous...

Страница 25: ...sm continous rotation CW from slow to fast 188 195 73 7 76 5 Stop 196 255 76 9 100 0 Prism continous rotation CCW from slow to fast 19 Frost 0 127 0 0 49 8 Off 0 0 128 255 50 2 100 0 On 20 Pan 0 255 0 0 100 0 Pan 0 0 21 Tilt 0 255 0 0 100 0 Tilt 46 18 0 22 Scan speed 0 255 0 0 100 0 Scan speed from fast to slow 0 0 23 Special controls 0 9 0 0 3 5 No function 0 0 10 19 3 9 7 5 Open light after 5 se...

Страница 26: ... 66 3 Built in program 5 170 179 66 7 70 2 Built in program 6 180 189 70 6 74 1 Built in program 7 190 199 74 5 78 0 Built in program 8 200 209 78 4 82 0 Built in program 9 210 219 82 4 85 9 Built in program 10 220 255 86 3 100 0 Reserved DMX protocol Extended 21 channels Revision A Valid from firmware version 1 0 DMX mode Name DMX value DMX percentage Function Default DMX Value Extended 33ch 1 St...

Страница 27: ...CMY color macro off 0 0 16 135 6 3 52 9 CMY synchronous color from slow to fast 136 255 53 3 100 0 CMY random color from slow to fast 11 CTO 0 255 0 0 100 0 Warm è Cold 0 0 12 0 65535 0 0 100 0 CTO fade fine LSB 13 Color1 wheel 0 9 0 0 3 5 Open 0 0 10 19 3 9 7 5 Color 1 20 29 7 8 11 4 Color 2 30 39 11 8 15 3 Color 3 40 49 15 7 19 2 Color 4 50 59 19 6 23 1 Color 5 60 69 23 5 27 1 Color 6 70 79 27 5...

Страница 28: ... 0 9 4 Gobo 8 25 26 9 8 10 2 Gobo 9 27 28 10 6 11 0 Gobo 10 29 30 11 4 11 8 Gobo 11 31 32 12 2 12 5 Gobo 12 33 34 12 9 13 3 Gobo 13 35 36 13 7 14 1 Gobo 14 37 42 14 5 16 5 Gobo 1 shake 43 48 16 9 18 8 Gobo 2 shake 49 54 19 2 21 2 Gobo 3 shake 55 60 21 6 23 5 Gobo 4 shake 61 66 23 9 25 9 Gobo 5 shake 67 72 26 3 28 2 Gobo 6 shake 73 78 28 6 30 6 Gobo 7 shake 79 84 31 0 32 9 Gobo 8 shake 85 90 33 3 3...

Страница 29: ... Gobo 4 28 32 11 0 12 5 Gobo 5 33 37 12 9 14 5 Gobo 6 38 42 14 9 16 5 Gobo 7 43 47 16 9 18 4 Gobo 8 48 57 18 8 22 4 Gobo 1 shake 58 67 22 7 26 3 Gobo 2 shake 68 77 26 7 30 2 Gobo 3 shake 78 87 30 6 34 1 Gobo 4 shake 88 97 34 5 38 0 Gobo 5 shake 98 107 38 4 42 0 Gobo 6 shake 108 117 42 4 45 9 Gobo 7 shake 118 127 46 3 49 8 Gobo 8 shake 128 187 50 2 73 3 Gobo wheel continous rotation CW from slow to...

Страница 30: ...12 5 100 0 On 24 Prism1 rotation 0 127 0 0 49 8 Prism indexed 0 0 128 187 50 2 73 3 Prism continous rotation CW from slow to fast 188 195 73 7 76 5 Stop 196 255 76 9 100 0 Prism continous rotation CCW from slow to fast 25 Prism2 0 31 0 0 12 2 Off 0 0 32 255 12 5 100 0 On 26 Prism2 rotation 0 127 0 0 49 8 Prism indexed 0 0 128 187 50 2 73 3 Prism continous rotation CW from slow to fast 188 195 73 7...

Страница 31: ...obo motor reset after 5 seconds 100 109 39 2 42 7 All strobe motor reset after 5 seconds 110 119 43 1 46 7 Other motor reset after 5 seconds 120 129 47 1 50 6 Built in program 1 130 139 51 0 54 5 Built in program 2 140 149 54 9 58 4 Built in program 3 150 159 58 8 62 4 Built in program 4 160 169 62 7 66 3 Built in program 5 170 179 66 7 70 2 Built in program 6 180 189 70 6 74 1 Built in program 7 ...

Страница 32: ...open CW CCW rotation variable speed Gobo outside diameter 14 4mm Max Image diameter 6 5mm Max Thickness 0 5mm Metal 1 1mm Glass Glass Metal gobo Glass Metal Color Color wheel 12 colors open split color CW CCW rotation variable speed Electrical Power input nominal AC 100 240V 50 60Hz Max Power consumption 722W max current 6 9A PF 0 99 Power supply unit Auto ranging electronic SMPS Main fuse 250V 10...

Страница 33: ...tartup range 5 F to 113 F 15 C to 45 C Storage range 40 F to 140 F 40 C to 60 C Cooling Active fan Humidity 85 Connections AC power equipped with lead wire DMX data input output cable with 3 pin Neutrik XLR plugs in out Certification and Safety EMC EN 55103 1 2009 EN 55103 2 2009 EN 61000 3 2 2006 A2 2009 EN 61000 3 3 2013 Safety EN 60598 2 17 1989 A2 1991 Photometric GTD 440P II BSW BEAM ...

Страница 34: ... technical engineer of GTD Lighting Notes Damage resulted from dust smoke oil or improper use is not covered by warranty Warning Disconnect the fixture from AC power and let it cool down for at least 15 minutes before opening the housing Make sure to use a soft cloth to clean the optical components and be careful as the coating is easily scratched Do not use any organic solvent such as alcohol to ...

Страница 35: ...nnector Open circuit or short circuit fault in the DMX cables Replace DMX cables as required Wrong DMX address for the fixture in the control system Ensure the address in Run setting Address Setting Address of the fixture is consistent with the address in the control system Misuse in Channel setting Channel Mode of the fixture Choose the channel mode in Channel setting Channel Mode of the fixture ...

Страница 36: ...he rotating gobo wheel static gobo wheel color wheel strobe prism and frost focus module and object lens Reinstall the lamp Adjust the lamp position until the midline of the lamp is aligned with the center point of the effect assemblies consisting of the rotating gobo wheel static gobo wheel color wheel strobe prism frost the focus adjusting module and the object lens Excessive dusts or smudges on...

Страница 37: ...r1 Motor2 Motor3 Motor4 Motor5 Motor6 Strobe2 Motor6 Fan Fan Fan Magnetic1 Magnetic4 Magnetic2 Magnetic5 Magnetic3 Magnetic6 SCR0400B enlarge Prism1 Atomizatio n Focus1 Motor1 Motor2 Motor3 Motor4 Motor5 Motor6 Prism rotation1 风机 风机 Magnetic1 Magnetic4 Magnetic2 Magnetic5 Magnetic3 Magnetic6 Motor1 5U01 4U01 4U02 GND 28V GND 28V Magnetic1 JE JEA Magnetic1 Photosensitive1 JE JEA Gobo1 C Gobo rotati...

Страница 38: ...9010312A 1 440P ⅡBSW 101A10 SDI0208D 5 Motor drive board 1C 5809010313A 1 440P ⅡBSW 201A10 SCR0001C 2 Motor drive board 16C 5809010316A 1 440P ⅡBSW 501A10 SCR0400B Motor drive board 5809010317A 1 440P ⅡBSW 301A10 302A10 SCR0009C Motor drive board 5809010318A 1 440P ⅡBSW 401A10 402A10 SCR0009C Fan drive board 7 5809010314A 1 440P ⅡBSW 601A10 SJB0300B Fan drive board 6 5809010315A 1 440P ⅡBSW 701A10...

Страница 39: ...Notes P N 1502011089A Time November 9 2018 ...

Отзывы: