13.
Weather
- Never operate your generator outdoors
during rain, snow or any combination of weather
conditions that could lead to moisture collecting on, in
or around the generator.
Dry Surface
- Always operate on a dry surface free of
any moisture.
No Connected Loads
- Make sure the generator has
no connected loads before starting it. To ensure there
are no connected loads, unplug any electrical
extension cords that are plugged into the control panel
receptacles.
NOTE:
Starting the generator with loads already
applied to it could result in damage to any appliance
being powered during the brief start-up period.
Grounding the Inverter Generator
- Consult with
your local municipalities for your grounding codes.
WARNING!
Always operate the generator on a level surface.
Placing the generator on non level surfaces can
cause it to tip over, resulting in fuel and oil spills.
Spilled fuel can ignite if it comes in contact with
an ignition source such as a very hot surface.
NOTE:
Operating the generator on a surface with
loose material such as sand or grass clippings can
cause debris to be ingested by the generator that
could block cooling vents or air intake system.
NEVER use inside a home
or garage, EVEN IF doors
and windows are open.
Only use OUTSIDE and
far away from windows,
doors, and vents.
DANGER!
Using a generator indoors can kill you in minutes.
Generator exhaust contains carbon monoxide.
This is a poison you cannot see or smell.
Avoid other generator hazards.
READ MANUAL BEFORE USE
WARNING!
Be sure the generator is properly connected to
earth ground before operating
.
High Altitude Operation -
Engine power is reduced
the higher you operate above sea level. Output will be
reduced approximately 3.5% for every 1000ft of
increased altitude from sea level. This is a natural
occurrence and cannot be adjusted by engine.
Increased exhaust emissions can also result due to
increased fuel mixture. Other issues include hard
starting, increased fuel consumption and spark plug
fouling.
High Altitude Carburetor Kit Part Number: 140540
WARNING!
Do not rest inverter on exhaust panel.
Do not move Generator while it is on.
The inverter will be damaged if operated in this
manner.
Before starting, always check the level of:
• Engine oil
• Gasoline in the fuel tank
Once the generator has started and the engine gets
warm it is not safe to add gasoline to the fuel tank or
engine oil to the engine while the engine is running or
the engine and muffler are hot.
WARNING!
Internal pressure can build in the engine
crank-case while the engine is running. Remov-
ing the oil fill plug/ dipstick while the engine is
hot can
cause extremely hot oil to spray out of the
crankcase and can severely burn skin. Allow
engine oil to cool for several minutes before
Preparation
www.gtpower.co.nz
removing the oil fill plug/dipstick.
Содержание GT4000ESi
Страница 1: ......
Страница 5: ...5 www gtpower co nz ...
Страница 6: ...6 www gtpower co nz ...
Страница 28: ...1 2 3 4 5 7 5 6 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 Engine Parts Diagram 28 www gtpower co nz ...
Страница 30: ...Wiring Diagram 30 3 6 8 1 2 4 5 7 9 10 黑白色 黄色 紫色 www gtpower co nz ...