III) INSTALLATION

Unpacking the Water Heater

Important:

Do not remove any permanent instructions,

labels, or the data label from outside of the water heater or
on the inside of panels.

Remove exterior packaging and place installation com-
ponents aside.

Inspect all parts for damage prior to installation and
start-up.

Completely read all instructions before attempting to
assemble and install this product.

If you observe damage to the water heater or any of its com-
ponents, DO NOT ASSEMBLE OR INSTALL IT OR MAKE
ANY ATTEMPT TO FIX THE DAMAGED PART(S). Contact
the place of purchase for further instructions.

After installation, dispose of packaging material in the
proper manner.

Location

Generally, the location selected should be as close to the
wall as practical and as centralized with the piping system
as possible. Heater should be located in an area not subject
to freezing temperatures.

The water heater should be located so that the controls and
drain are easily accessible.

CAUTION: When this water heater is installed directly on
carpeting, carpeting must be protected by a metal or wood
panel beneath the appliance extending beyond the full width
and depth of the appliance by at least 76mm (3 in.) in any
direction, or if the appliance is installed in an alcove or clos-
et, the entire floor must be covered by the panel. The panel
must be strong enough to carry the weight of the heater
when full of water. Failure to heed this warning may result in
a fire hazard.

Minimum clearances between the heater and com-
bustible/non combustible materials are 0mm (0 in.) at the
sides and rear; 508mm (20 in.) from the top of water heater
and 25mm (1 in.) around the vent pipe. A minimum of
915mm (3 ft.) of clearance is required at the front (control)
side of the heater for service.
For a closet installation, the door at burner side should be
openable and a minimum of 102mm (4 in.) clearance is
needed. Water heater is certified for installation on a com-
bustible floor (see Figure 1).

– 5 –

0mm (0 in.) 

0mm (0 in.)

ALCOVE INSTALLATION
(TOP VIEW)

0mm (0 in.)

0mm (0 in.)

CLOSET INSTALLATION
(TOP VIEW)

102mm (4 in.)

CLOSET DOOR

Figure 1 

Minimum Installation Clearances

IMPORTANT:

This water heater must be installed strictly in accordance
with the instructions enclosed, and local electrical, fuel
and building codes. It is possible that connections to the
water heater, or the water heater itself, may develop
leaks. IT IS THEREFORE IMPERATIVE that the water
heater be installed so that any leakage of the tank or relat-
ed water piping is directed to an adequate drain in such a
manner that it cannot damage the building, furniture, floor
covering, adjacent areas, lower floors of the structure or
other property subject to water damage. This is particular-
ly important if the water heater is installed in a multi-story
building, on finished flooring or carpeted surfaces. GSW
WILL NOT ASSUME ANY LIABILITY for damage caused
by water leaking from the water heater, pressure relief
valve, or related fittings. Select a location as centralized
within the piping system as possible. In any location
selected, it is recommended that a suitable drain pan be
installed under the water heater. This pan must limit the
water level to a MAXIMUM depth of 45mm (1 3/4 in.) and
have a diameter that is a minimum of 50mm (2 in.) greater
than the diameter of the water heater. Suitable piping shall
connect the drain pan to a properly operating floor drain.

WARNING

Excessive Weight Hazard

Use two or more people to move and install
water heater. Failure to do so can result in
back or other injury.

Содержание 61009 (09-03)

Страница 1: ...other flammable vapours and liquids in the vicinity of this or any other appliance Installation and service must be per formed by a qualified installer service agency or the gas utility Do not try to...

Страница 2: ...0 IV OPERATING INSTRUCTIONS 11 Lighting instructions Robertshaw 110R Lighting instructions White Rodgers 37C Special note on propane fuel Out of fuel Water Temperature Regulation 13 Exposure to water...

Страница 3: ...r any property damage personal injury or death resulting from improper sizing installation or failure to comply with these instructions The warranty on this water heater is in effect only when the wat...

Страница 4: ...nts T P All water heaters must be fitted with a proper temperature and pressure relief valve These valves must be certified as meeting the requirements of the Standard For Relief Valves For Hot Water...

Страница 5: ...minimum of 915mm 3 ft of clearance is required at the front control side of the heater for service For a closet installation the door at burner side should be openable and a minimum of 102mm 4 in cle...

Страница 6: ...tributor and damage to your carrier Note The four fasteners that are required to secure the vent terminal to the exterior wall are not provided These should be screw type not nails chosen for the type...

Страница 7: ...and terminal are assembled by the manufac turer as shown in Figure 3C There are springs fastened inside the corrugated pipe When the vent pipes are pulled to a required length the distances between t...

Страница 8: ...he vent pipe s level or slope again and adjust if required Offset vent pipe arrangement Figure 3K CONDITION 1 Where a straight vent pipe arrangement is impossible a horizontal 90 degree maximum bend c...

Страница 9: ...be installed ahead of the gas valve to permit easy removal of the unit All leak testing must be done with a soapy water solution NEVER USE A MATCH OR OPEN FLAME TO TEST FOR GAS LEAKS A FIRE OR EXPLOSI...

Страница 10: ...preventer or water pressure reducing valve This will create a closed water system During the heating cycle of the water heater the water expands caus ing pressure inside the water heater to increase...

Страница 11: ...setting 10 Replace the outer door 1 Set the thermostat to lowest setting Turn counter clockwise 2 Turn the gas control knob OFF Rotate clockwise WARNING If you do not follow these instructions exactly...

Страница 12: ...replace the outer burner door 12 Set thermostat to desired setting 13 If the pilot will not stay lit after several tries turn the gas control knob clock wise to OFF see Figure A If the appliance will...

Страница 13: ...burner and pilot flames The burner flames must be a soft blue flame with no yellow tips Yellow tips indicate a carbonizing flame which can depending on severity deposit carbon soot on the combustion c...

Страница 14: ...off at the inlet to the heater 2 Turn water off at the cold water inlet valve 3 Open a nearby hot water tap 4 Drain approximately one pail full of water from the heater 5 With a 1 1 16 in hexagon sock...

Страница 15: ...or space heating 5 If the space heating water system requires water with temperatures in excess of 60 C 140 F a mixing valve or other means must be installed in the potable hot water supply to temper...

Страница 16: ...cturer will furnish the Owner with a replacement for the defective part s This warranty is limited to one replacement component part for each original part 3 Return of Defective Water Heater and Compo...

Страница 17: ...rges for labour or other expenses incurred in the removal repair or replacement of the water heater or any component part s claimed to be defective or any expense incurred to remedy any defect in the...

Отзывы: