Safety Warning (Flammable Vapours)

There is a risk of property damage, personal injury or death
from the by-products of combustion (e.g., flue gases), in
using fuel-burning appliances such as water heaters. Areas
that may not be suitable for water heater installation include
those where flammable liquids, gasoline, solvents, adhe-
sives etc. are stored, or where engine-driven equipment or
vehicles are stored, operated or repaired. These, and simi-
lar products, should not be stored or used near the water
heater or air intake. Due to the nature of air movement,
flammable vapours can be carried some distance from the
point of storage. The gas-fired water heater igniter or burn-
er flame can ignite these vapours causing a flashback, fire
or explosion, which may result in severe property damage,
serious personal injury or death. If flammable liquids or
vapours have spilled or leaked in the area of the water
heater, leave the area immediately and call the fire depart-
ment from a neighbor’s home. Do not attempt to clean the
spill until all ignition sources have been extinguished.

Safety Warning (Scalding)

Hot water produced by this appliance can cause severe
burns due to scalding. The hazard is increased for young
children, the aged or the disabled when water temperatures
exceed 52°C (125°F). Use tempering valves, also known as
mixing valves, in the hot water system to reduce the risk of
scalding at point-of-use such as lavatories, sinks and
bathing facilities. Such precautions must be followed when

this heater is operated in combination with dishwashing or
space heating applications.

Safety Warning (Carbon Monoxide)

Relief Valve Requirements (T&P)

All water heaters must be fitted with a proper temperature
and pressure relief valve. These valves must be certified as
meeting the requirements of the “

Standard For Relief

Valves For Hot Water Supply Systems, ANSI
Z21.22/CSA 4.4”

.

If this water heater has been exposed to flooding, freezing,
fire or any unusual condition, do not put it into operation until
it has been inspected and approved by a qualified service
technician.

THESE CONDITIONS CAN RESULT IN UNSEEN INTER-
NAL DAMAGE

and are not subject to warranty coverage.

DANGER

DANGER

Carbon Monoxide Warning

• Follow all vent system requirements by

the local authorities having jurisdiction
over your installation.

• Failure to do so can result in death, explo-

sion or carbon monoxide poisoning.

CAUTION

Hydrogen gas can be produced in a hot water system
served by this heater that has not been used for a long
period of time (generally two (2) weeks or more).

Hydrogen gas is extremely flammable and can ignite
when exposed to a spark or flame.

To reduce the risk of

injury under these conditions, it is recommended that the
hot water faucet be opened for several minutes at the
kitchen sink before using any electrical appliance con-
nected to the hot water system. Use caution in opening
faucets. If hydrogen is present, there will probably be an
unusual sound such as air escaping through the pipe as
the water begins to flow. There should be no smoking or
open flame near the faucet at the time it is open.

– 4 –

WARNING

Flammable Vapours

FLAMMABLES

FIRE AND EXPLOSION HAZARD

Can result in serious injury or death

Do not store or use gasoline or other flammable vapours and liquids

in the vicinity of this or any other appliance. Storage of or use of gasoline

or other flammable vapours or liquids in the vicinity of this or any other

appliance can result in serious injury or death.

Содержание 61009 (09-03)

Страница 1: ...other flammable vapours and liquids in the vicinity of this or any other appliance Installation and service must be per formed by a qualified installer service agency or the gas utility Do not try to...

Страница 2: ...0 IV OPERATING INSTRUCTIONS 11 Lighting instructions Robertshaw 110R Lighting instructions White Rodgers 37C Special note on propane fuel Out of fuel Water Temperature Regulation 13 Exposure to water...

Страница 3: ...r any property damage personal injury or death resulting from improper sizing installation or failure to comply with these instructions The warranty on this water heater is in effect only when the wat...

Страница 4: ...nts T P All water heaters must be fitted with a proper temperature and pressure relief valve These valves must be certified as meeting the requirements of the Standard For Relief Valves For Hot Water...

Страница 5: ...minimum of 915mm 3 ft of clearance is required at the front control side of the heater for service For a closet installation the door at burner side should be openable and a minimum of 102mm 4 in cle...

Страница 6: ...tributor and damage to your carrier Note The four fasteners that are required to secure the vent terminal to the exterior wall are not provided These should be screw type not nails chosen for the type...

Страница 7: ...and terminal are assembled by the manufac turer as shown in Figure 3C There are springs fastened inside the corrugated pipe When the vent pipes are pulled to a required length the distances between t...

Страница 8: ...he vent pipe s level or slope again and adjust if required Offset vent pipe arrangement Figure 3K CONDITION 1 Where a straight vent pipe arrangement is impossible a horizontal 90 degree maximum bend c...

Страница 9: ...be installed ahead of the gas valve to permit easy removal of the unit All leak testing must be done with a soapy water solution NEVER USE A MATCH OR OPEN FLAME TO TEST FOR GAS LEAKS A FIRE OR EXPLOSI...

Страница 10: ...preventer or water pressure reducing valve This will create a closed water system During the heating cycle of the water heater the water expands caus ing pressure inside the water heater to increase...

Страница 11: ...setting 10 Replace the outer door 1 Set the thermostat to lowest setting Turn counter clockwise 2 Turn the gas control knob OFF Rotate clockwise WARNING If you do not follow these instructions exactly...

Страница 12: ...replace the outer burner door 12 Set thermostat to desired setting 13 If the pilot will not stay lit after several tries turn the gas control knob clock wise to OFF see Figure A If the appliance will...

Страница 13: ...burner and pilot flames The burner flames must be a soft blue flame with no yellow tips Yellow tips indicate a carbonizing flame which can depending on severity deposit carbon soot on the combustion c...

Страница 14: ...off at the inlet to the heater 2 Turn water off at the cold water inlet valve 3 Open a nearby hot water tap 4 Drain approximately one pail full of water from the heater 5 With a 1 1 16 in hexagon sock...

Страница 15: ...or space heating 5 If the space heating water system requires water with temperatures in excess of 60 C 140 F a mixing valve or other means must be installed in the potable hot water supply to temper...

Страница 16: ...cturer will furnish the Owner with a replacement for the defective part s This warranty is limited to one replacement component part for each original part 3 Return of Defective Water Heater and Compo...

Страница 17: ...rges for labour or other expenses incurred in the removal repair or replacement of the water heater or any component part s claimed to be defective or any expense incurred to remedy any defect in the...

Отзывы: