GSW 61009 (09-03) Скачать руководство пользователя страница 2

I) INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

II) SAFETY. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

III) INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

Unpacking the Water Heater

5

Location

5

Venting

6

Vent connections
Offset vent pipe arrangement
High rise vent pipe arrangement

Gas Connections

9

Gas Supply

9

Water Piping

9

Temperature & Pressure Relief Valve

10

The discharge line:
Closed system/Thermal expansion

Installation Checklist

10

IV) OPERATING INSTRUCTIONS . . . . . . . . . . . . . . . 11

Lighting instructions (Robertshaw 110R)
Lighting instructions (White-Rodgers 37C)
Special note on propane fuel:
Out of fuel

Water Temperature Regulation

13

Exposure to water
Tampering

Burner Maintenance

13

Gas Control

13

V) MAINTENANCE INSTRUCTIONS . . . . . . . . . . . . 14

General Housekeeping

14

Tank

14

Venting System Inspection

14

Temperature & Pressure Relief Valve

14

Cathodic Protection

14

Control

14

VI) COMBO HEATING . . . . . . . . . . . . . . . . . . . . . . . . 15

LIMITED WARRANTY. . . . . . . . . . . . . . . . . . . . . . 16

– 2 –

TABLE OF CONTENTS

RETAIN THESE INSTRUCTIONS IN A SAFE LOCATION FOR FUTURE REFERENCE

Содержание 61009 (09-03)

Страница 1: ...other flammable vapours and liquids in the vicinity of this or any other appliance Installation and service must be per formed by a qualified installer service agency or the gas utility Do not try to...

Страница 2: ...0 IV OPERATING INSTRUCTIONS 11 Lighting instructions Robertshaw 110R Lighting instructions White Rodgers 37C Special note on propane fuel Out of fuel Water Temperature Regulation 13 Exposure to water...

Страница 3: ...r any property damage personal injury or death resulting from improper sizing installation or failure to comply with these instructions The warranty on this water heater is in effect only when the wat...

Страница 4: ...nts T P All water heaters must be fitted with a proper temperature and pressure relief valve These valves must be certified as meeting the requirements of the Standard For Relief Valves For Hot Water...

Страница 5: ...minimum of 915mm 3 ft of clearance is required at the front control side of the heater for service For a closet installation the door at burner side should be openable and a minimum of 102mm 4 in cle...

Страница 6: ...tributor and damage to your carrier Note The four fasteners that are required to secure the vent terminal to the exterior wall are not provided These should be screw type not nails chosen for the type...

Страница 7: ...and terminal are assembled by the manufac turer as shown in Figure 3C There are springs fastened inside the corrugated pipe When the vent pipes are pulled to a required length the distances between t...

Страница 8: ...he vent pipe s level or slope again and adjust if required Offset vent pipe arrangement Figure 3K CONDITION 1 Where a straight vent pipe arrangement is impossible a horizontal 90 degree maximum bend c...

Страница 9: ...be installed ahead of the gas valve to permit easy removal of the unit All leak testing must be done with a soapy water solution NEVER USE A MATCH OR OPEN FLAME TO TEST FOR GAS LEAKS A FIRE OR EXPLOSI...

Страница 10: ...preventer or water pressure reducing valve This will create a closed water system During the heating cycle of the water heater the water expands caus ing pressure inside the water heater to increase...

Страница 11: ...setting 10 Replace the outer door 1 Set the thermostat to lowest setting Turn counter clockwise 2 Turn the gas control knob OFF Rotate clockwise WARNING If you do not follow these instructions exactly...

Страница 12: ...replace the outer burner door 12 Set thermostat to desired setting 13 If the pilot will not stay lit after several tries turn the gas control knob clock wise to OFF see Figure A If the appliance will...

Страница 13: ...burner and pilot flames The burner flames must be a soft blue flame with no yellow tips Yellow tips indicate a carbonizing flame which can depending on severity deposit carbon soot on the combustion c...

Страница 14: ...off at the inlet to the heater 2 Turn water off at the cold water inlet valve 3 Open a nearby hot water tap 4 Drain approximately one pail full of water from the heater 5 With a 1 1 16 in hexagon sock...

Страница 15: ...or space heating 5 If the space heating water system requires water with temperatures in excess of 60 C 140 F a mixing valve or other means must be installed in the potable hot water supply to temper...

Страница 16: ...cturer will furnish the Owner with a replacement for the defective part s This warranty is limited to one replacement component part for each original part 3 Return of Defective Water Heater and Compo...

Страница 17: ...rges for labour or other expenses incurred in the removal repair or replacement of the water heater or any component part s claimed to be defective or any expense incurred to remedy any defect in the...

Отзывы: