![GST GRS-825DM-BC Скачать руководство пользователя страница 24](http://html1.mh-extra.com/html/gst/grs-825dm-bc/grs-825dm-bc_user-manual_2275654024.webp)
Bell Mobility User Manual
In-building Repeater
23
When output
power is no
longer problem
* Technician should connect
antenna with output port of
repeater.
* Please make sure all
connectors are fastened
* Reconnect the connector.
* Change it if the connector is defective.
When output
power is no
longer problem
* Check the input level
* Increase output power or check input change of BTS side.
When output
power is no
longer problem
* Check Gain of the unit
* If the Gain is different from normal level, please contact A/S
team.
When output
power is no
longer problem
* Cable connector loose.
* It is possible for connectors to get too tight and damage the
equipment or throughput.
* Please contact installer or service provider upon verification.
In case of
dropped call
or bad
signal after
set up
* Check input signal strength
in the service area
* Increase output power level of repeater by adjusting
attenuation level.
In case of drop
call or bad
signal after
set up
* If input signal strength is not
a problem, please check
delay of calling time.
* Increase output level of Uplink signal, then set to optimal
level.
In case of
dropped call
or bad
signal after
setup
* Check RSSI signal strength
* Contact network management team or service provider