![GST GRS-825DM-BC Скачать руководство пользователя страница 18](http://html1.mh-extra.com/html/gst/grs-825dm-bc/grs-825dm-bc_user-manual_2275654018.webp)
Bell Mobility User Manual
In-building Repeater
17
4.1.4 Open for Service
1) Check points before open:
a. Verification of system installation status:
- Electricity, In/Out antennas, cable connection, and equipment mount status.
b. Verification of system accessories:
- User should check all necessary accessories.
c. Check receipt signal level
- Installer should check whether environmental conditions are in accordance
with system specification to ensure that system operation will be optimized.
2) Check points after open:
a. Check external LED
1) RUN: Green light ON (Off: all lights off)
2) ALARM: Green light in normal status, Red light in alarming
3) SHUT DOWN: Green light in normal status, Red light in Shutdown status
800MHz 25dBm:
Number of LED bars on front side of repeater will show input signal level.
Less than ~ -85dBm: LED 1bar
-84dBm~-67dBm: LED 2 bars
-66dBm~-49dBm: LED 3 bars
-48dBm~-31dBm: LED 4 bars
More than -30dBm: LED 5 bars
Number of LED bars on front side of repeater will show output power signal level.
Less than +5dBm: LED 1 Bar
+6dBm ~ +10dBm: LED 2 Bar
+11dBm ~ +15dBm: LED 3 Bar
+16dBm ~ +20dBm: LED 4 Bar
More than +21dBm: LED 5 Bar