![GST GRS-825DM-BC Скачать руководство пользователя страница 15](http://html1.mh-extra.com/html/gst/grs-825dm-bc/grs-825dm-bc_user-manual_2275654015.webp)
Bell Mobility User Manual
In-building Repeater
14
Power
Monitoring
Function
• Monitoring repeater’s output level
Oscillation Check
• Isolation Check in initial set up or Reset
• Monitoring Oscillation comparing to minimum/maximum Noise Floor level
• When Oscillation occurred, repeater attempts to stabilize Isolation through Gain control function.
• Shutdown repeater when Oscillation still occurs in Minimum Gain
• Automatic Recovery Algorithm conversion after Shutdown status
Spurious
Emission Alarm
• Noise Floor Observation in case of ±2.25MHz down at the center
• In case of Noise level > –13dBm, Spurious Emission is stabilized automatically
• In case of Oscillation Spurious Emission Alarming in Minimum Gain, repeater will be shutdown
• Automatically Switch to Recovery Algorithm at Shutdown
DL Input control • Monitoring Donor ANT input power of DL
Automatic
Recovery
• When repeater is shutdown, it periodically recovers output power of repeater then monitors
alarming
Security
• Support HTTPS for Web Browser security
• User authentication through User ID and Password
Temperature
Control
• Monitoring temperature of repeater
• Maximum and minimum set up is possible. Shutdown in over temperature
• Automatic recovery after temperature becomes normal. (Hysteresis 10degree)
VSWR
Monitoring
• Monitoring VSWR of Donor ANT Port (Every 90 seconds)
• Reporting VSWR Alarm and Shutdown when the rate is 3:1
• Automatic Recovery Algorithm conversion after Shutdown status
IP address
report via E-mail
• When in PPP reconnection, E-mail which includes HTML to connect to newly assigned IP Address,
reports to operator.
DHCP Client
• Automatic IP assignment
DHCP Server
• Server function for automatic IP assignment
Web GUI
• Remote and local user browser support through Web Browser
SNMP Agent
• NMS report via SNMPv2 Trap
LED Display
• LED displays power and operation status on front side of repeater system.
• Input and Output signal levels are verified by LED bars.