- 20 -
PEDQ 3005/4005/5005 QMX
• Use
to make a selection between the automatic ("
auto
") and manual
("
man
") assignment of the TS/ORGNET identification.
• With the "
man
" setting (manual), use
to position the cursor under the
part of the identification number (ID) to be set and use
to enter the
desired ID.
—> A TS/ORGNET identification with the value "
0000,FFFF
" is invalid.
• Press the
key.
—> The "Setting hotel mode –
HOTELMODE:
" menu is activated.
Setting hotel mode
The hotel mode is designed for special applications and should only activated
for these applications. If the hotel mode was inadvertently activated please
observe the section "Deactivating the hotel mode" below.
Hotel mode is required to generate a fixed assignment of the PIDs when in-
put data changes. That means that if the PIDs of the incoming data stream
change, the outgoing data stream is given a single defined PID. Even if there
is no input signal, the entries in the tables remain unchanged. If the incom
-
ing data stream contains several stations, only the station that is found first is
transmitted. The manual selection of the input signals via the station filter is not
possible.
Box 4
off
HOTELMODE:
• Use
to select between activated hotel mode ("
on
") and deactivated
hotel mode ("
off
").
—> If hotel mode is activated, the service information is assigned to the four
channel strips.
The "Setting the station filter" and "Reading out the sta-
tion filter" menus cannot be selected.
Deactivating the hotel mode:
To deactivate the hotel mode set the hotel mode to "off" with buttons
and store the setting with button .
After that disconnect the mains plug of the
head end station from the mains and then reconnect it. Only after a "reboot"
the station filters work properly.
• Press the
key.
—> The "Naming channel strips –
NAME:
" menu is displayed.