background image

GSM POWER SOCKET USER MANUAL 

 

30 

The 

Master

 user sends following SMS message in order to: 

Enable the “Beep” warning tone:

                                  #19#1#         

(34)

 

Disaable the “Beep” warning tone (Default):

              #19#0#         

(35) 

 

 

Successful SMS reply 

Beep alarm activated/de-activated. 
 

3.11 Check status 

 

Method 

The 

Master

 user sends following SMS message in order to: 

Check socket operating status:         

#07#                                         

(36)

 

After receiving the SMS commands, 

GSM Power Socket

 will reply one 

SMS message of socket status checking: 

Number:***********,********** 
Status: ON/OFF 
TEMP:** 
Temp control:function ON/OFF 
Schedule control:function ON/OFF 
Delay control:function ON/OFF 

Check socket output status:           

#000#                                           

(37) 

After receiving the SMS commands, 

GSM Power Socket

 will reply one 

SMS message of socket output status: 

Status: ON 
Temp:23. 

Check “delayed switch on/off the socket” parameters: 

#138#     

(38) 

After receiving the SMS commands, 

GSM Power Socket

 will reply one 

SMS  message  of  “Delayed  switch  on/off  the  socket”  parameters 
checking:   

Status: ON/OFF 
Output will switch off/on after ** minutes.   

Check “Timing switch on the socket” parameters:   

#128#           

(39) 

After receiving the SMS commands, 

GSM Power Socket

 will reply one 

Содержание Power Socket

Страница 1: ...GSM Power Socket User Manual ...

Страница 2: ...rature sensor GSM power socket can switch on or off the socket output according to the environment temperature It s available for power control of the heating or refrigeration plant to keep the environmental temperature within presetting range or at a fixed temperature value Furthermore a SMS notification will be sent to master s mobile phone if GSM Power Socket detects the rapid changing or the r...

Страница 3: ... 2 1 Install the SIM card and temperature sensor 12 2 2 GSM Power on off 12 2 3 Add a Master number to the socket 13 2 4 The regulation of time 14 2 5 Socket output switching on off 14 2 6 External power supply notification 15 Chapter 3 Advanced settings 16 3 1 Define the users 16 3 2 Change password 19 3 3 Switching on off the socket output manually 19 3 4 Delayed switch on off the socket output ...

Страница 4: ...S notification upon the socket output changing 28 3 9 SMS notification upon external power supply changing 29 3 10 Beep warning tone 29 3 11 Check status 30 3 12 Resetting the socket 32 Chapter 4 Maintenance 33 Chapter 5 General Troubleshooting 34 Chapter 6 Main Technical Parameters 36 Appendix SMS commands list 37 ...

Страница 5: ...nsure your safety For your safety This socket was designed for home or office use Do not use it on the electrical appliance which is for industry or business operation for example iatrical appliances large heaters and refrigerates Before using this socket make sure that the mobile phones can be used well in the area otherwise do not put this socket into operation The power consumption of the appli...

Страница 6: ... of the children reach Exception clause 1 We operate on a policy of continuous development We reserve the right to make changes and improvements to any of the sockets described in this document without prior notice 2 We don t guarantee for the document veracity reliability or any content except regulate in proper laws Including no guarantee for socket suitable market or suitable area promise 3 We ...

Страница 7: ...ixing time control output power on off External temperature sensor supported Send environmental temperature SMS to mobile phone Auto operates by temperature Available for power control of the heating or refrigeration plant to keep the environmental temperature within presetting range or at fixed temperature value SMS alarm when temperature rapid changing or reaching the pre set value When it detec...

Страница 8: ...GSM POWER SOCKET USER MANUAL 8 1 2 Package contents GSM power socket 1 unit Temperature sensor 1 unit User manual 1 unit ...

Страница 9: ...GSM POWER SOCKET USER MANUAL 9 1 3 Sockets instructions Figure 1 GSM Power Socket instructions ...

Страница 10: ...urning off No power supply input Constant light Has power supply input GSM Blue light Turning off Not installed SIM card or the power switch of socket is OFF Flash Be busy or searching GSM network Constant light Successfully load to GSM network Output Red light Constant light The socket outlet has power supply Turning off The socket outlet cuts power supply ...

Страница 11: ...anges power supply status Several times GSM Power Socket lost external power supply Long Beep GSM Power Socket is successfully register GSM network or it is successfully reset to its factory settings Note The Beep warning tone can be turn on or turn off by SMS command Refer to Chapter 3 9 for details ...

Страница 12: ...Cover back the metallic cover and push it to LOCK direction The SIM card will be fixed in the holder Screw the SIM cover back Insert the temperature sensor into the I O port until it is seized 2 2 GSM Power on off Power on 1 Turn the power switch to On position See 7 on Figure1 2 Plug the GSM Power Socket in an AC power socket See 6 on Figure1 The blue light will be flashing slowly for about 20 se...

Страница 13: ...IM card working abnormally all functions of this socket are invalid 2 Check GSM network signal of the using place The GSM network s signal strength may affect the socket feature Therefore before using the user should ensure that GSM Power Socket is used in an area with a strong GSM network signal For the first time use the user should perform a test run by sending SMS to the socket This allows the...

Страница 14: ...message in order to Regulate the socket time 152 SIMCardNumber 1 The SIMCardNumber should be the SIM card number of GSM Power Socket Successful SMS reply The socket current time is yyyy mm dd hh mm 2 5 Socket output switching on off Method Method 1 To press M button 0 5 second See 3 on Figure1 Method 2 The Master user sends following SMS message to socket in order to Switch on the socket output 01...

Страница 15: ...tify the user Main electricity supply lost Temp Resume external power supply If the AC power of GSM Power Socket is available again the SMS notification will be sent to the user i e Main electricity supply restore Status ON OFF Temp When the external power supply is resumed the output of GSM Power Socket will keep its previous working status For example if the output is switched on before the exte...

Страница 16: ... user must store his her mobile number in the socket s memory Only one Master s mobile number Master number is allowed for a socket Family users There are four Family users have authorization to use two commands of switch on or cut off the socket output The other mobile phone users have no authorization to use GSM Power Socket 3 1 2 About the SMS Command Master user s SMS command format code conte...

Страница 17: ...t Method The user must edit and send the following SMS to socket via his her mobile phone the phone number will be the Master number in order to Add a master number to the socket 00 2 Successful SMS reply Welcome to use GSM Power Socket Your Password is 1234 Failed SMS reply If a user tries to add another Master user again GSM Power Socket will send a notification via SMS stating The master user a...

Страница 18: ...Power Socket anymore 3 1 5 Add a family number Up to 4 family users number can be stored on one socket Family users have the authority to send SMS command to switch on or cut off the GSM Power Socket output The family users should remember and safeguard the socket s SIM number Method The Master user sends following SMS message in order to Add a family number 06 FamilyNumber 4 Add several family nu...

Страница 19: ...ssword 04 Oldpassword Newpassword 9 The password is a four digit number The original password is 1234 Successful SMS reply New password is 3 3 Switching on off the socket output manually Description When the socket output is switching on GSM Power Socket offers power supply for electronic appliance which being connected with it the red indicator light is lighted constantly Otherwise GSM Power Sock...

Страница 20: ... off the socket output manually 02 Password 13 Password should be 4 digits password number Default 1234 SMS reply will be also sent to Master user when Family users use these two commands to change the socket output successfully Successful SMS reply Status ON OFF Temp Temp control function ON OFF Schedule control function ON OFF Delay control function ON OFF 3 3 2 Switching on off by M button Keep...

Страница 21: ...layed switch on off the socket function is applied the preset timed switch on the output function will be invalid at once When the delayed switch on the socket command is received and if the socket output is switched on the socket output will be switched off immediately and be switch on again as the setting delayed time is reaching Contrarily if the socket output is switched off the output will re...

Страница 22: ...won t be changed Successful SMS reply Status ON OFF Output will switch off on after minutes 3 5 Timed switching on the socket output 3 5 1 Enable timing switching on the output Description The output of GSM Power Socket can be set to switch on for a duration and then be switch off after the duration If the socket output status is changed manually including pressing M button sending SMS and making ...

Страница 23: ...settings 3 5 2 Set time period to switch on the output Description After successful setting of time duration to switch on the socket output the schedule parameter will be saved on the socket until GSM Power Socket is reset to factory settings But the timed switch on the output feature is applied only when command 17 be set Method The Master user sends following SMS message in order to Set time per...

Страница 24: ... Schedule control function ON OFF WorkDay StartTime EndTime 3 5 3 Disable timing switching on the output Method The Master user sends following SMS message in order to Disable timing switch on the output 128 0 20 Successful SMS reply Schedule control function OFF WorkDay StartTime EndTime 3 6 Auto control the socket output by temperature 3 6 1 Enable auto controlled by temperature Description The ...

Страница 25: ...users set the GSM Power Socket output is on from 9am to 5pm In this case the socket will control to switch on or off the output according to indoor temperature automatically from 9am to 5pm duration Method The Master user sends following SMS message in order to Enable auto control the output by temperature 159 1 21 Successful SMS reply Status ON OFF Temp control function ON Temp Mode Heating Cooli...

Страница 26: ...t will be switched on to power heating apparatus and if the environmental temperature is 24 degrees above the limitation of 20 degrees in the command the socket output will be switched off and the heating apparatus stops working Example 2 set commands 159 1 10 20 if the environmental temperature is 26 degrees above the limitation of 20 degrees in the command the socket output will be switched on t...

Страница 27: ... set temperature range the GSM Power Socket will auto send the SMS alarm message to master s mobile phone This feature depends on the temperature sensor Method The Master user sends following SMS message in order to Enable over temperature alarm 170 1 24 Set limits of temperature 170 MinTemp MaxTemp 25 MinTemp and MaxTemp The values can be set within the range of 10 to 50 centigrade degree Default...

Страница 28: ...e 160 Temp Time 28 Temp The values lie in the range of 1 to 50 centigrade degree Time The values lie in the range of 1 to 300 minutes Default Temp is 2 degree and Time is 1 minute Disable the temperature rapid changing alarm 160 0 29 Successful SMS reply Fast temperature changing function ON OFF Delta Time minutes 3 8 SMS notification upon the socket output changing Description GSM Power Socket wi...

Страница 29: ...Main electricity supply restore Status ON Temp The Master user can enable disable this SMS notification Method The Master user sends following SMS message in order to set SMS notification upon the power supply changing Default 12 1 32 No SMS notification upon the power supply changing 12 0 33 Successful SMS reply No SMS notification upon main electricity supply changing 3 10 Beep warning tone Desc...

Страница 30: ...checking Number Status ON OFF TEMP Temp control function ON OFF Schedule control function ON OFF Delay control function ON OFF Check socket output status 000 37 After receiving the SMS commands GSM Power Socket will reply one SMS message of socket output status Status ON Temp 23 Check delayed switch on off the socket parameters 138 38 After receiving the SMS commands GSM Power Socket will reply on...

Страница 31: ...or User needs to check if the temperature sensor is inserted to the I O port Check temperature rapid changing alarm parameters 160 41 After receiving the SMS commands GSM Power Socket will reply one SMS message of parameters It means SMS alarm message will be sent upon the surrounding temperature changes Delta centigrade degree within minutes Fast temperature changing function ON OFF Delta Time mi...

Страница 32: ...ers can restore the socket to its original status to make it work normally Note This function needs to be used carefully as it also erases all setting values Method Method 1 Press the side M button of the device for 5 seconds Method 2 The Master user sends following SMS message to GSM Power Socket in order to Reset the socket 08 43 Successful SMS reply Reset the socket to factory setting successfu...

Страница 33: ...ot store and use it in the bathroom or other place with high humidity Do not allow pour water or other liquids into the socket otherwise it might cause malfunctions Do not store and use the socket in dusty Do not use alcohol acetone and other similar solvents to clean it Wipe it with soft wet cloth Do not attempt to open it except as instructed If the socket does not work normally try to resolve i...

Страница 34: ...button No power input The power switch is OFF Check GSM Power Socket s external AC power is available Power on the socket 4 All functions disable Indicator is working Caller ID presentation do not active insufficient fee of the SIM card Contact network provider to active SIM card function Pay for the card 5 Socket didn t response of any operation GSM Power Socket work abnormally Switch off the pow...

Страница 35: ...mber already exists Other master is already set in the socket Change Master number or recover to factory default setting 8 Invalid format Please check and try again Invalid command Refer to the user manual 9 No authorization user Use the Master mobile phone to try the command again Note If the problem can t be solved with above guidelines contact to your local distributor or after service center ...

Страница 36: ...110 230V 50HZ 230V 30A 30s 16A long duration CEE7 4 German Schuko Operating temperature 10 50 Store temperature 20 60 Relative humidity 10 90 without condensation Communication protocols GSM PHASE 2 2 including data operation Data interface GSM SIM 1 8V 3 0V socket External temperature sensor 10 50 GSM working band GSM850 EGSM900 DCS1800 PCS1900 Optional ...

Страница 37: ...mbers simultaneously 7 113 FamilyNumber 1 FamilyNumber4 Delete all family numbers 8 113 Change the password 9 04 Oldpassword Newpassword Switching on off output manually Master user switches on the socket output manually 10 01 Master user cuts off the socket output manually 11 02 Family user switches on the socket output manually 12 01 Password Family user cuts off the socket output manually 13 02...

Страница 38: ...ch on off the output 22 159 Mode LowTe mp HighTemp Disable auto control the output by temperature 23 159 0 Over temperatur e alarm Enable the over temperature alarm 24 170 1 Set limits of temperature 25 170 MinTemp MaxTemp Disable the over temperature alarm 26 170 0 Temperatu re rapid changing alarm Enable the temperature rapid changing alarm 27 160 1 Set time period and temperature changing value...

Страница 39: ...1 Disaable the Beep warning tone Default 35 19 0 Check status Check socket operating status 36 07 Check Socket output status 37 000 Check Delayed switch on off the socket parameters 38 138 Check Timed switch on the socket parameters 39 128 Check Temperature control parameters 40 159 Check temperature rapid changing alarm parameters 41 160 Check over temperature alarm parameters 42 170 Reset to fac...

Страница 40: ...GSM POWER SOCKET USER MANUAL 40 GSM Power Socket ...

Отзывы: