Fitting Instructions

Thank you for purchasing Mistral bathroom 

heater. This product combines heat globes 

an exhaust fan and  light, to provide gentle 

radiant heat, clean air and a bright light from 

one compact, stylish unit. This model allows for 

exhausting of steam and odours right out of your 

home. All functions are separately controlled 

from a supplied switch plate for convenient 

fingertip control.

You can be assured trouble free operation by 

getting your Mistral Bathroom heater carefully 

installed by a qualified electrician, according 

to the instructions. Please read all instructions 

before commencing installation.

Mistral Bathroom heater can be mounted in 

any room that requires instant, direct, and 

radiant heat to ward off winter chills. The light 

has separate switching, making it suitable for 

bathrooms, ensuites, toilets, dressing & change 

rooms.

Suitability

The Mistral Bathroom Heater has been designed 

especially for cavity type ceilings.  Flat roof 

installation is NOT recommended.

This product must not be mounted in areas 

subject to direct splashing, and must be 

mounted in the horizontal position only. 

Unsuitable for ‘cathedral’ or ‘raked’ ceilings.

This model comes with 2 Infrared Heat Globes 

which emit harmless radiant heat. It is best 

positioned directly above the area requiring 

warmth. Before you start, make sure your ceiling 

has at least 280mm clearance from the roof (see 

to the ‘Mounting’ diagram).

Where to Locate

Radiant globe heaters are not designed to heat 

entire rooms. They provide instant, concentrated 

heat to persons standing directly below the heat 

lamps. Therefore, Mistral Bathroom heater should 

be located over the area where drying off takes 

place, not directly over a shower or bath.

This Heater is not designed to be left on for 

extended periods of time, as this could cause 

overheating and premature failure. Mistral 

Bathroom Heater,  should not be covered or 

installed in situations which restrict the natural 

ventilation of the units for cooling purposes.

Ceiling insulation should be kept well clear 

of the units (at least 100mm). For optimum 

performance, models with exhaust fans should 

be installed in areas with good ventilation, 

to enable fresh air to flow into the room. Any 

restrictions on return air entering the room will 

impair effectiveness and may contribute to 

premature failure.

Radiant Heat

The Mistral Bathroom Heater requires no warm 

up period because of its efficient, radiant heat 

globes. Heat is directed at you for an instant 

warmth you can feel, rather than gradually 

warming the entire room. Because of this, Mistral 

Bathroom Heater only needs to be turned ON 

when you are in the room.

General Illumination

A  6  watt light is designed to provide general 

illumination only. Additional lighting may be 

required for duties.

Содержание mistral ML506

Страница 1: ...3 In 1 Bathroom Heater Model ML506 Instruction Manual ...

Страница 2: ...amage electrical wiring and other hidden utilities This bathroom heater is to be installed so that switches or other controls can not be touched by a person in the bath or shower The lamps are extremely hot when in use Do not touch to the lamps with any part of your body when in use Allow all lamps cool down sufficiently before touching or replacement The appliance shall under no circumstances be ...

Страница 3: ...rea requiring warmth Before you start make sure your ceiling has at least 280mm clearance from the roof see to the Mounting diagram Where to Locate Radiant globe heaters are not designed to heat entire rooms They provide instant concentrated heat to persons standing directly below the heat lamps Therefore Mistral Bathroom heater should be located over the area where drying off takes place not dire...

Страница 4: ...er and accessories from the plastic bag and carton Please assemble the air outlet before mounting the unit into the hole Air outlet assemble steps as below 4 Connect the ducting if required to the outer grille of the unit Insert the unit into the square hole being sure to pull the side clips inward so that the body can pass through the hole without damaging the plaster Rotate the swing clips to ho...

Страница 5: ... and fix another end of duct to vent louvres with metal clip Electrican s Wiring Instructions Your Mistral Bathroom Heater requires a 220 240 Volt 50Hz electrical supply All electrical work must be carried out by a qualified electrician and installed in accordance with relevant Electrical Wiring Regulations Your new Mistral Bathroom Heater comes with all required switches and mounting plates How 1...

Страница 6: ...omatically When cool down the fan will close accordingly Replacement of Lamp 1 Check and tighten lamp regularly 2 Shut off power before replacement 3 Use E27 6W LED for lighting 4 Use E27 275W infrared lamp for heating Technical Specifications Power Supply AC 220 240V 50Hz Power Consumption 581W 2 x 275W Heat lamps 6W LED Light NOTE As a result of continual improvements the design and specificatio...

Страница 7: ... goods come with guarantees which cannot be excluded under the Australian Consumer Law if purchased in Australia or the Consumer Guarantees Act 1993 if purchased in New Zealand You are entitled to replacement or refund for a major failure and to compensation for other reasonably foreseeable loss or damage You are also entitled to have the goods repaired or replaced if the goods fail to be of accep...

Страница 8: ...8 Cat No ML506 April 2020 ...