CGA SERIES 2000 HEATER INSTALLATION
PLENUM TEMPERATURE
SENSOR MOUNTING
The plenum temperature sensor is
the small gray PVC junction box at-
tached by a cord to the fan/heater
control box.
1. 24" to the right side of the transi-
tion, drill one 3/8" hole in the cen-
ter of the plenum in a valley on
the bin sidewall.
2. Insert the probe through the hole.
3. Position the housing so that the
tabs are vertical, and the cord
exits the housing horizontally.
4. Use two self drilling screws to mount
the housing to the bin sidewall.
5. Caulk between the housing and
the sidewall to seal.
Plenum temperature sensor installation.
1. Mark location on transition one
(1) foot up from the bottom
(entrance collar) and centered
in the transition.
2. Drill or knock out 7/8" diameter
hole on marked location.
3. Install transition hi-limit using
supplied self drilling screws.
TRANSITION HI-LIMIT INSTALLATION
Figure 1: The transition connecting the Series 2000 Heater to the bin with
the plenum sensor in place.