GSi Airstream 2000 Series Скачать руководство пользователя страница 5

5

WARRANTY

EXCEPT FOR THE ABOVE STATED EXPRESS LIMITED WARRANTIES, GSI MAKES NO WARRANTY OF
ANY KIND, EXPRESSED OR IMPLIED, INCLUDING, WITHOUT LIMITATION, WARRANTIES OF MER-
CHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OR USE IN CONNECTION WITH (i) PROD-
UCT MANUFACTURED OR SOLD BY GSI OR (ii) ANY ADVICE, INSTRUCTION, RECOMMENDATION OR
SUGGESTION PROVIDED BY AN AGENT, REPRESENTATIVE OR EMPLOYEE OF GSI REGARDING OR
RELATED TO THE CONFIGURATION, INSTALLATION, LAYOUT, SUITABILITY FOR A PARTICULAR PUR-
POSE, OR DESIGN OF SUCH PRODUCT OR PRODUCTS.

IN NO EVENT SHALL GSI BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL OR CONSEQUEN-

TIAL DAMAGES, INCLUDING, WITHOUT LIMITATION, LOSS OF ANTICIPATED PROFITS OR BENEFITS.
PURCHASER'S SOLE AND EXCLUSIVE REMEDY SHALL BE LIMITED TO THAT STATED ABOVE, WHICH
SHALL NOT EXCEED THE AMOUNT PAID FOR THE PRODUCT PURCHASED. THIS WARRANTY IS NOT
TRANSFERABLE AND APPLIES ONLY TO THE ORIGINAL PURCHASER. GSI SHALL HAVE NO OBLIGA-
TION OR RESPONSIBILITY FOR ANY REPRESENTATIVE OR WARRANTIES MADE BY OR ON BEHALF
OF ANY DEALER, AGENT OR DISTRIBUTOR OF GSI.

GSI ASSUMES NO RESPONSIBILITY FOR FIELD MODIFICATIONS OR ERECTION DEFECTS WHICH

CREATE STRUCTURAL OR STORAGE QUALITY PROBLEMS. MODIFICATIONS TO THE PRODUCT NOT
SPECIFICALLY COVERED BY THE CONTENTS OF THIS MANUAL WILL NULLIFY ANY PRODUCT WAR-
RANTY THAT MIGHT HAVE BEEN OTHERWISE AVAILABLE.

THE FOREGOING WARRANTY SHALL NOT COVER PRODUCTS OR PARTS WHICH HAVE BEEN

DAMAGED BY NEGLIGENT USE, MISUSE, ALTERATION OR ACCIDENT. THIS WARRANTY COVERS
ONLY PRODUCTS MANUFACTURED BY GSI. THIS WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL
OTHER WARRANTIES EXPRESS OR IMPLIED. GSI RESERVES THE RIGHT TO MAKE DESIGN OR SPECI-
FICATION CHANGES AT ANY TIME.

PRIOR TO INSTALLATION, PURCHASER HAS THE RESPONSIBILITY TO RESEARCH AND COM-

PLY WITH ALL FEDERAL, STATE AND LOCAL CODES WHICH MAY APPLY TO THE LOCATION AND
INSTALLATION.

THE GSI GROUP, INC. ("GSI") WARRANTS ALL PRODUCTS MANUFACTURED BY GSI TO BE FREE OF
DEFECTS IN MATERIAL AND WORKMANSHIP UNDER NORMAL USAGE AND CONDITIONS FOR A PE-
RIOD OF TWELVE MONTHS AFTER RETAIL SALE TO THE ORIGINAL END USER OF SUCH PROD-
UCTS. GSI'S ONLY OBLIGATION IS, AND PURCHASER'S SOLE REMEDY SHALL BE FOR GSI, TO RE-
PAIR OR REPLACE, AT GSI'S OPTION AND EXPENSE, PRODUCTS THAT, IN GSI'S SOLE JUDGMENT,
CONTAIN A MATERIAL DEFECT DUE TO MATERIALS OR WORKMANSHIP. ALL DELIVERY AND SHIP-
MENT CHARGES TO AND FROM GSI'S FACTORY WILL BE PURCHASER'S RESPONSIBILITY. EXPENSES
INCURRED BY OR ON BEHALF OF THE PURCHASER WITHOUT PRIOR WRITTEN AUTHORIZATION
FROM AN AUTHORIZED EMPLOYEE OF GSI SHALL BE THE SOLE RESPONSIBILITY OF THE PURCHASER.

Содержание Airstream 2000 Series

Страница 1: ...1 Owner s Manual MANUAL PNEG 582 CGAApproved Series2000Heater InstallationAnd OperatingInstructions MODEL VHC __ __ __ __ 2 __ HIGH MODEL VLC __ __ __ __ 2 __ LOW...

Страница 2: ...CURRENT INSTALLATION CODES FOR GAS BURNING APPLIANCES AND EQUIPMENT CAN1 B149 1 AND B149 2 OR APPLICABLE PROVINCIAL REGULATIONS WHICH SHOULD BE CAREFULLY FOLLOWED IN ALL CASES AUTHORITIES HAVING JURI...

Страница 3: ...ane Vapor Models 12 Fuel Connection For Natural Gas Models 12 Series 2000 Operating Procedure 13 Power Up 13 Normal Operating Displays With Heater Not Running 14 Starting The Dryer 15 Setting Gas Pres...

Страница 4: ...e gauge _____ 9 Regulator adjusted _____ 10 Shut off valve operates correctly _____ 11 Vapor high limit _____ 12 Unit cycles ON to OFF _____ 13 Heat rise even across transition _____ 14 Unit cycles HI...

Страница 5: ...DIFICATIONS TO THE PRODUCT NOT SPECIFICALLY COVERED BY THE CONTENTS OF THIS MANUAL WILL NULLIFY ANY PRODUCT WAR RANTY THAT MIGHT HAVE BEEN OTHERWISE AVAILABLE THE FOREGOING WARRANTY SHALL NOT COVER PR...

Страница 6: ...vailable in both propane vapor and natural gas models The principal concern of the GSI Group Inc GSI is your safety and the safety of others associated with grain handling equipment This manual is wri...

Страница 7: ...r is supplied to your unit Safety decals should be read and understood by all people in the grain handling area The bottom right decal should be present on the inside bin door cover of the two ring do...

Страница 8: ...8 1128 7 32 Blue 2 20 3 4 2842 23 64 Aluminum 1 7 1 1 4 28 28 1 8 29 5 8 25 1 4 3000000 140 34 15 64 Aluminum 2 20 3 8 1253 15 64 Aluminum 2 20 3 4 3157 3 8 Aluminum 1 7 1 1 4 HIGH TEMPERATURE HEATER...

Страница 9: ...bs are vertical and the cord exits the housing horizontally 4 Usetwoselfdrillingscrewstomount the housing to the bin sidewall 5 Caulk between the housing and the sidewall to seal Plenum temperature se...

Страница 10: ...2 WIRING HEATER UNIT SERIES 2000 HEATER INSTALLATION 4 Third heater unit may also be added to system If adding third unit run connections to master unit 1 and connect them in parallel with secondary h...

Страница 11: ...lled by an electrician Ground rods and wires are not sup plied by Airstream It is recom mended that the rod not be driven into dry ground The following steps en sure proper ground rod installation 1 D...

Страница 12: ...RKING ON OR AROUND HEATER 1 Natural gas models are de signed to run directly off of a supply tank or from a separate external vaporizer 2 Run proper size line see speci fication on page 6 to pipe trai...

Страница 13: ...is con dition may be bypassed with the FAN BYPASS switch All safety and high limit switches are checked upon power up If a safety or limit is open the control displays it The control cannot operate wi...

Страница 14: ...The heater display with fan on airflow is displayed if air is flowing or not flowing RX TX receive transmit is displayed if multiple heaters are connected All safeties or high limits are continuously...

Страница 15: ...or 4 6 lbs for natural gas units use the charts on the following pages to set pressure 15 Press the PROGRAM TEM PERATURE button to change the high limit set point Press it again to change the CYCLE S...

Страница 16: ...14 10 8 4 180 9 6 3 17 11 4 3 26 22 11 8 18 16 13 11 5 20 18 13 10 5 GAUGE PRESSURE PSI REQUIRED TO MAINTAIN TEMPERATURE APPROXIMATE HIGH TEMP UNITS ONLY 2 102900 148370 Diameter 18 24 28 4 145970 210...

Страница 17: ...2 205200 251710 1 144100 177840 Operating Pressure PSI Diameter 18 24 28 60 1 1 low temp 1 1 low temp low temp 2 1 1 low temp 1 1 1 1 low temp 1 1 1 1 low temp Fan Model 3HP 18 7HP 24 10HP 24 15HP 26...

Страница 18: ...17 for setting the hi lo flame temperature If the temperature is above the high temperature setting the flame will be off the FLAME message will be out and the display will be flashing OFF CYCLE If t...

Страница 19: ...may be done at anytime unless an error condi tion exists even while the dryer is in operation Programming a system with The limits are continuously checked during the drying operation A limit switch o...

Страница 20: ...e shutdown mode Then the fan and heater shut down when the time expires This is indi cated by the lower left cursor flash ing Depressing the start switch again while holding in on the SHUTDOWN HOURS s...

Страница 21: ...aters Multiple heaters connected together through the serial link Master with one slave dip switch 7 on all others off Slave 1 dip switch one on all others off Master with two slaves dip switch 8 on a...

Страница 22: ...ay SLA on the main display and the RX TX symbols will be flashing If a limit switch error or one of the error numbers 1 through 8 occurs that error is displayed on the slave where the error originates...

Страница 23: ...Disconnect and lock out power to fan and heater Open control box lid and inspect all compo nents for moisture vibration or rodent damage Inspect and tighten all loose terminal con nections Replace any...

Страница 24: ...24 SERIES 2000 HEATER WIRING...

Страница 25: ..._____________________________________________________ ___________________________________________________________________________________________________ ______________________________________________...

Страница 26: ...26 1004 E Illinois St Assumption IL62510 phone217 226 4421 fax217 226 4498 June1996...