2. Install the top two bolts (3) to the blower assembly brackets (6) leaving space between the bolt head
and nut (4).
3. Slide the bolt heads into the slots on the blower mount bracket (1).
4. Install the bottom two bolts (3) in the blower assembly brackets and tighten all the bolts.
Figure 7-2
Installing the blower to the bracket
1
Blower mount bracket (D01-2958)
4
5/16 in. flange nut (S-3611)
2
Center flange
5
Blower assembly (D04-1016)
3
5/16 x 3/4 in. flange bolt (S-6606)
6
Blower assembly bracket (D01-2952 and D01-2959)
5. Install the conduit hangers (7) into existing bolt holes on the dryer using screws (8).
Figure 7-3
Conduit hangers installation
7
Conduit hangers (S-6643)
9
5/16 x 1 in. bolt (S-1196)
8
#10 x 5/8 in. self-drilling screw (S-280)
10
5/16 in. hex nut (S-400)
46
PNEG-2132
Pressure Cooled Quiet Portable Dryer