24' Batch & Autoflow
EAVE FLASHING INSTALLATION
Install the eave flashing centered on the floor sheet (1 per) with the bent edge towards the sidewall install a fender
washer (S-3671) and nut. Screw the flashing to the flashing angle at the dump hopper opening with (5) #10 (S-
280) screws and screw the flashing pieces together where they overlap with (3) #10 self drilling (S-280) screws.
¬
-
#10 Self-
Drilling Screws
(S-280)
-
¯
Figure #31
FLASHING BOLT INSTALLATION
Install the eave flashing bolts (5/16" x 1.1/4") through the sidewall and tighten first nut. Note at the vertical
sidewall seams, one bolt is turned around to avoid interference with eave flashing (refer to photo).
Eave Flashing Holes
Left bolt on the each vertical sidewall
seam level with the eave flashing bolts
(as viewed from inside the bin) is to be
installed bolt in, nut out, as shown in
the photo to the right.
Flashing Attachment. 1) Sidewall, 2) Flashing TD-
100648, 3) Floor sheet, 4) 5/16" x 1.1/4" bin bolt. Note
that there is a nut in between the sidewall sheet and the
flashing sheet.
Floor Flashing
Angle (TD-100654)
INSTALLATION
Figure #30