37
24' Batch & Autoflow
Figure #30
Center Lift Plate
Center Collar
8th hole
4th hole
Leveling Band Posts
Optional Rotary Switch
S-277
5/16" x 1.1/4" Bin
Bolt
Install the leveling band posts on the floor as shown.
The third and eighth holes in the floor sheet indicate the location of the leveling band posts. Attach posts with
5/16" x 1.1/4" bin bolts (S-277). The third hole from the bottom of the sheet, there will be 7 posts (1 every third
sheet, except the last bay will cover five sheets). In the eighth hole there will be 5 posts (1 every fourth sheet).
After all of the posts have been installed fill the unused holes with 5/16" x 1.1/4" bin bolts.