![GSI Group 890-00584 Скачать руководство пользователя страница 85](http://html1.mh-extra.com/html/gsi-group/890-00584/890-00584_installation-and-configuration-manual_2275189085.webp)
Chapter 12: Configuring an Intrusion Zone
Providing Enough Time to Exit After Arming
Once you have armed your system, you must have enough time to exit the building without setting off an
alert.
Before You Begin
Attention
Only the entry zones can have an
Exit delay
. You must click on the
Entry zone
button to make the zone
an entry zone to have access to the field.
What You Should Know
NOTE:
Only zones configured as intrusion type zones can be armed.
1. In edit mode, under the
General
tab, click in the edit field next to the
Exit delay
.
2. Enter the time needed to exit the building after arming.
Activating the at Home Arming
When your building is equipped with motion detectors, and you would like to arm the windows and doors,
you can activate the at home arming.
In edit mode, under the
General
tab, click on the at home arming button.
The green LED lights when the at home arming is enabled.
Activating the Chime on an Intrusion Zone Type
In edit mode, under the
General
tab, click on the box next to the chime icon.
A checkmark indicates that the chime is enabled.
Activating a device in the Event of an Alert or Trouble
A device, such as a fan or a heater, can be turned on or off when an alert condition or trouble is detected in
a zone. To do so, a programmable output must be activated in the zone.
1. In edit mode, under the
Action
tab, click on the edit field next to the event type you want the device’s
output linked to.
A list of available outputs is displayed.
NOTE:
Only the previously configured outputs are displayed.
2. Click in the box to the left of the chosen output.
Receiving a Phone Call When an Alert is Active
In the event of an alert in a zone, the system calls the phone numbers selected to inform key people of the
alert state.
What You Should Know
895-00677
Agri Alert 128 Touch
85
Содержание 890-00584
Страница 14: ...NOTES 14 895 00677 Agri Alert 128 Touch...
Страница 20: ...NOTES 20 895 00677 Agri Alert 128 Touch...
Страница 30: ...NOTES 30 895 00677 Agri Alert 128 Touch...
Страница 38: ...NOTES 38 895 00677 Agri Alert 128 Touch...
Страница 44: ...NOTES 44 895 00677 Agri Alert 128 Touch...
Страница 64: ...Chapter 9 Configuring a 0 5 Volt Zone Type 64 895 00677 Agri Alert 128 Touch...
Страница 66: ...NOTES 66 895 00677 Agri Alert 128 Touch...
Страница 82: ...NOTES 82 895 00677 Agri Alert 128 Touch...
Страница 88: ...NOTES 88 895 00677 Agri Alert 128 Touch...
Страница 92: ...NOTES 92 895 00677 Agri Alert 128 Touch...
Страница 96: ...NOTES 96 895 00677 Agri Alert 128 Touch...
Страница 100: ...NOTES 100 895 00677 Agri Alert 128 Touch...
Страница 102: ...NOTES 102 895 00677 Agri Alert 128 Touch...
Страница 106: ...NOTES 106 895 00677 Agri Alert 128 Touch...
Страница 107: ...F Wiring Diagram with Terminals 895 00677 Agri Alert 128 Touch 107...
Страница 108: ...Appendix F Wiring Diagram with Terminals Wiring diagram with a DPST disconnect switch 108 895 00677 Agri Alert 128 Touch...
Страница 109: ...Appendix F Wiring Diagram with Terminals Wiring diagram with a SPST disconnect switch 895 00677 Agri Alert 128 Touch 109...
Страница 110: ...NOTES 110 895 00677 Agri Alert 128 Touch...
Страница 118: ......