1. Important User Information  

 

Preliminary 

 The usability and the life cycle of the heatless regenerative air-dryer (referred to below as PHL-

dryers) as well as the avoidance of premature repairs depends on proper operation, care and 

competent repair under consideration of these operating instructions. 

 

 

Product Information 

 

Due to our position as suppliers of components we do not always know the final usage and 

total range of products’ applications. We constantly improve our products to the latest state 

of science and technology and therefore, we assume that our products are free from defects 
in the sense of product liability. However, it cannot be excluded that during faulty operation 
in critical areas of application especially at danger to life and limb of persons involved, 
additionally safety measures may be necessary. 
 Therefore, we request the user of our components / units, to ensure in his own interest, to 
inform us about the application of our products in order to initiate additional safety 
measures, if 

necessary.

 

 

 

General Notes  

 The Company does not accepts responsibility if these safety measures are not met during 
handling, operation, maintenance and repair, even though this is not strictly stated in these 
operating instructions. 
We recommend receipt and notice of these operating instructions verified by the operating 
personnel in writing (personnel file). 
We request strict observation of these notes as otherwise we do not accept any liability in 
respect of this machine (plant). 
 

 

 

 

 

 

 

Safety Regulations

 

• Protective or safety devices must not be removed, modified or readjusted.

 

• During operation of the dryer none of the protective of safety devices must be removed, 

modified or readjusted temporarily or permanently. 

• Use proper tools for maintenance and repair work only.

 

• Use original spare parts only.

 

• All maintenance works must be performed at stopped machine, disconnected power supply 

and pulled mains plug only. Ensure that the dryer cannot be switched on by mistake. 

• Prior to dismounting a part under pressure disconnect the dryer from all pressure sources 

or depressurize the complete system respectively. 

• Never weld the pressure vessel or modify it in any way.

 

• Ensure that no tools, loose parts or similar are left in the system.

 

• Wear eye protection and protective gloves during the change of desiccant.

 

 

Caution! 

 

The operator has to observe the national working-, operating- and safety    

 

regulations. Also existing internal factory regulations must be met. 

 

Maintenance and repair work must only be carried out by specially trained  

 

personnel and, if necessary, under supervision of a person qualified for this work. 

Содержание Desiccant

Страница 1: ...lease read this manual before using this equipment must Learn all the safety precautions before using this equipment please keep Desiccant Air Dryer Heatless Type Operating Manual http www gsadryer co...

Страница 2: ...5 Light 5 Sound Pressure Level 5 Chapter 2 2 General Descriptions Purpose 6 Composition 6 Principle of Operation 6 Operation 7 Repressurizing Solenoid Valve 7 Fault Alarm 7 Chapter 3 Installation Wiri...

Страница 3: ...r 11 Control Air Filter 11 Purge Flow Rate Adjustment 11 Solenoid Valve 12 Desiccant Replacement 12 Maintenance Schedule 13 Troubleshooting 14 Chapter 6 Appendix Control Panel 15 Purge Air Calibration...

Страница 4: ...d in these operating instructions We recommend receipt and notice of these operating instructions verified by the operating personnel in writing personnel file We request strict observation of these n...

Страница 5: ...y the factory in accordance with the appropriate code of practice and factory regulations Sound Pressure Level If the sound pressure level is larger proper safety method is needed to the operator such...

Страница 6: ...pneumatic valve check valve solenoid valve and control panel The compressed air with moisture vapor enters a tower and flows upward through the desiccant bed The desiccant has great affinity for mois...

Страница 7: ...plete the inlet selector valve will switch inlet valves and the inlet air gas stream will divert from the left tower to the right tower After five seconds the left tower purge exhaust valve will conti...

Страница 8: ...nt suppression will decrease Operation of the dryer in ambient approaching freezing could cause freezing of separated liquids in the pre filter sump or in the dryer itself For dryer operation at tempe...

Страница 9: ...stream demand for dry air frequently occurs a rapid pressure loss in the compressed air system is possible To prevent this it is recommended that a back pressure regulator be installed down stream fr...

Страница 10: ...t one tower will depressurize to atmospheric pressure Regenerating purge air will then flow through the regenerating tower 5 Set the purge adjustment valve to 45 psig 3 1 barg The purge pressure can b...

Страница 11: ...nt Replacement of the element will enhance system operation and prevent inflow of desiccant powder to load side Control air filter The control air filter should be inspected periodically and replaced...

Страница 12: ...m to verify that the solenoid coil is receiving electrical input A burned out coil Replace the coil Clogged solenoid valve Disassemble and clean Damaged valve seat Disassemble and clean Desiccant repl...

Страница 13: ...ntaminants Replace if contaminated Control air filter Inspect filter element or regulator if needed clean the filter regulator Every 6 months Calibrate dew point meter if installed Refer to dew point...

Страница 14: ...lose Check de press purge valve And check its solenoid valve Excessive press drop Excessive flow rate Check working pressure Low Inlet pressure Check line pressure Tower change failure No control air...

Страница 15: ...SV1 B Tower Right Tower On Line SV2 B Tower Right Tower Purge SV3 A Tower Left Tower On Line SV4 A Tower Left Tower Purge SV5 Re Pressure Tower Select A or B Tower Select DPOS Dew Point Operating Sys...

Страница 16: ...ibration Chart 60 50 40 30 20 10 10 20 30 40 50 60 70 80 90 100 110 120 130 RATED FLOW OR NORMAL CAPACITY PURGE PRESSURE PSIG 5 0 6 0 70 80 90 100 110 120 130 140 150 Sequence chart 5 minutes drying c...

Страница 17: ...2017 05 GSA CO Ltd Head office Factory 679 2 Sinwol ri chowol eup Gwangju si Gyeonggi do KOREA TEL 82 31 798 0171 FAX 82 31 798 0175 www gsadryer com E mail gsa gsadryer com...

Отзывы: