22
IQAN-LC5-X05 Technical Overview
Appendix A
Instruction book, IQAN-LC5-X05
IQAN-LC5-X05, base
System
T
A
= -40 to +85 °C, unless otherwise specified
Parameter
Limit values
Unit
Remark
min.
typ.
max.
Weight, base unit
Weight, base unit + MP handle
380
750
g
Ambient temperature,
T
ROC
– 40
+85
°C
recommended operating
Voltage supply,
V
S
4.5
5.0
5.5
V
Current consumption, base only
33
46
mA
V
S
= 5.0 V
Electrical characteristics
Parameter
Limit values
Unit
Remark
min.
typ.
max.
Number of VOUT
4
antivalent signals
VOUT, minimum position
400
500
600
mV
over life of unit
VOUT, center position
2400
2500
2600
mV
over life of unit
VOUT, maximum position
4400
4500
4600
mV
over life of unit
VOUT linearity error
300
mV
Max difference on output
signal A or B from ideal
VOUT A and B difference
375
mV
Max difference between
output signals A/B
VOUT resolution
12
bits
=1.22 mV
Response time
6
ms
Load, resistive
4.5
kohm
Load, capacitive
1
µF
Continuous voltage
5.5
V
Protection
SCG
Mechanical ratings
Parameter
Limit values
Unit
Remark
min.
typ.
max.
Angle of movement
±18
deg.
Deflection moment, neutral
0.6
Nm
Deflection moment, fully actuated
1.4
Nm
One time loading
100
Nm
Exceptional condition
Expected life
5x10
6
cycles
One cycle: Neutral to full +
direction to neutral to full -
direction and back to neu-
tral