20
Output signals
6 Installation
Instruction book, IQAN- LC5-X05
Connecting of -MP handle outputs
When you connect the IQAN-LC5-X05 joystick handle functions to a module or
standalone controller you may have proportional outputs from thumbwheels, or on-off
outputs from buttons. For the proportional outputs, you may use both OUT-A and
OUT-B signals from the thumbwheels. The primary signal for the axis is connected to a
VIN,
voltage input
and the secondary signal for the axis, if used, is connected to a
separate VIN on the controller module.
Connect each primary output 10%-90% Vs output signal to VIN, and optionally
connect the corresponding secondary output 90%-10% Vs output signal to another
VIN.
W
ARNING
The previous example is presented with limited information to explain the use of
primary and secondary signals from the -MP handle thumbwheels. Safety
considerations such as the use of an ’operator present’ switch to enable outputs etc. are
always recommended.
EXAMPLE
Connecting -MP thumbwheel outputs to a module.
to valve section controlled
to valve section controlled
OUT-W1B (optional)
OUT-W2B (optional)
OUT-W1A
OUT-W2A
by thumbwheel 2 of joystick
by thumbwheel 1 of joystick
IQAN module
MP handle
VIN
VIN
VIN
VIN