- Send Alarm Message by FTP/E-Mail:
The Administrator can select whether to send an alarm message by FTP and/or E-Mail when tampering is
detected.
- Upload Image by FTP:
After selecting this item, the Administrator can assign a FTP site and configure various parameters as shown in
the figure below. When tampering is detected, event images will be uploaded to the appointed FTP site.
- Upload Image by E-Mail:
After selecting this item, the Administrator can assign an e-mail address and configure various parameters as
shown in the figure below. When tampering is detected, event images will be sent to the appointed e-mail
address.
NOTE: Make sure SMTP or FTP configuration has been completed. See section 9.5. Mail and 9.6. FTP for further
details.
The pre-trigger buffer recording function allows users to check what happened to trigger the alarm. The pre-
trigger buffer time range is from 1 to 3 seconds.
Select <Upload for __ sec> to set the recording duration after the alarm is triggered. The setting range is from 1
to 99999 seconds.
Select <Upload while trigger is active> to record the triggered video until the trigger is turned off.
- Send HTTP notification:
Check this item, select the destination HTTP address, and specify the parameters for HTTP notifications. When
the Tampering Alarm is triggered, the HTTP notifications can be sent to the specified HTTP server.
For instance, if the custom parameter is set as ”action=1&group=2”, and the HTTP server’s name is
”http://192.168.0.1/admin.php”, the notification will be sent to the HTTP server as ”http://192.168.0.1/admin.php?
action=1&group=2” when an alarm is triggered.
File Name :
The uploaded image’s filename format can be set in this section. Please select the one that meets your
requirements (please see the section "File Name" in 9.8. Application).
Save :
Click the Save button to save all the Tampering Alarm settings mentioned above.