background image

Limited Warranty

Products  manufactured  by  GRUNDFOS  PUMPS  CORPORATION 
(GRUNDFOS)  are  warranted  to  the  original  user  only  to  be  free 
of  defects  in  material  and  workmanship  for  a  period  of  24  months 
from date of installation, but not more than 30 months from date of 
manufacture. GRUNDFOS' liability under this warranty shall be limited 
to repairing or replacing at GRUNDFOS' option, without charge, F.O.B. 
GRUNDFOS'  factory  or  authorized  service  station,  any  product  of 
GRUNDFOS manufacture. GRUNDFOS will not be liable for any costs 
of removal, installation, transportation, or any other charges which may 
arise in connection with a warranty claim. Products which are sold but 
not manufactured by GRUNDFOS are subject to the warranty provided 
by the manufacturer of said products and not by GRUNDFOS' warranty. 
GRUNDFOS will not be liable for damage or wear to products caused by 
abnormal operating conditions, accident, abuse, misuse, unauthorized 
alteration or repair, or if the product was not installed in accordance with 
GRUNDFOS' printed installation and operation instructions.

To obtain service under this warranty, the defective product must be 
returned  to  the  distributor  or  dealer  of  GRUNDFOS  products  from 
which it was purchased together with proof of purchase and installation 
date, failure date, and sup-porting installation data. Unless otherwise 
provided, the distributor or dealer will contact the GRUNDFOS factory 
or  authorized  service  station  for  instructions.  Any  defective  product 
to be returned to the factory or service station must be sent freight 
prepaid; documentation supporting the warranty claim and/or a Return 
Authorization must be included if so instructed.

GRUNDFOS WILL  NOT  BE  LIABLE  FOR  ANY  INCIDENTAL  OR 
CONSEQUENTIAL DAMAGES, LOSSES, OR EXPENSES ARISING 
FROM  INSTALLATION,  USE,  OR  ANY  OTHER  CAUSES. THERE 
ARE  NO  EXPRESS  OR  IMPLIED  WARRANTIES,  INCLUDING 
MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, 
WHICH EXTEND BEYOND THOSE WARRANTIES DESCRIBED OR 
REFERRED TO ABOVE.

Some jurisdictions do not allow the exclusion or limitation of incidental 
or  consequential  damages  and  some  jurisdictions  do  not  allow 
limitations  on  how  long  implied  warranties  may  last. Therefore,  the 
above limitations or exclusions may not apply to you. This warranty 
gives you specific legal rights and you may also have other rights which 
vary from jurisdiction to jurisdiction.  

Grundfos Pumps Corporation
17100 W. 118th Terrace
Olathe, Kansas 66061
Telephone: (913) 227-3400
Fax: (913) 227-3500

Grundfos Canada, Inc.
2941 Brighton Rd.
Oakville, Ontario L6H 6C9
Telephone: (905) 829-9533
Fax: (905) 829-9512

Bombas Grundfos de Mexico, S.A. de C.V.
Boulevard TLC #15, 
Parque Industrial Stiva Aeropuerto
C.P. 66600 Apodaca, N.L. Mexico
Telephone: 52-81-8144-4000
Fax: 52-81-8144-4010

 L-UP-TL-042 

9/08

PRINTED IN USA

Содержание UP15-42F

Страница 1: ...nd Operation 1 2 3 4 5 6 7 Electrical Pump Installation Operational Limits General Features Shipment Inspection Settings Quick Reference GRUNDFOS INSTRUCTIONS Pumps Incorporating the VS Variable Speed...

Страница 2: ...roper installation and operation of this control could result in damage to the equipment and possibly even personal injury It is your responsibility to ensure that this control is safely installed acc...

Страница 3: ...and safety devices must be added Offset dial provides fine tuning for input signal Manual dial provides manual speed control Range of signal is selected through Dip Switch A Type of signal used is se...

Страница 4: ...re intended for use with water or a 50 50 mixture by weight of propylene glycol UP15 42F VS 115V 60 Hz Maximum Fluid Temperature 205 F 96 C Maximum Ambient 107 F 42 C with control module vertical Fig...

Страница 5: ...freely Remove the large screw in the middle of the nameplate insert a small flat blade screwdriver into the end of the shaft and turn gently If the shaft does not turn easily repeat the disas sembly...

Страница 6: ...ge remaining air from the bearing chamber This is especially important when installing the pump during the off season 5 Electrical Warning All electrical work should be performed by a qualified electr...

Страница 7: ...he wires Current Speed Control Signal Connections Connect the current signal wires to terminals Com and Ret I Fig 3 Test the Speed Control Signal Wiring Make sure exposed wires and bare terminals are...

Страница 8: ...f the pump will have a range from minimum speed 15 to a maximum speed 100 Dip Switch D speed control external speed control maximum dial When dip switch D is in the ON position an external V dc mA sig...

Страница 9: ...al allows the speed of the pump to be manually adjusted and set by the user The speed of the pump may be manually adjusted anywhere from min to 100 but once set remains fixed at that speed The min pos...

Страница 10: ...10V 4 20mA min speed off speedcontrol manual dial speedcontrol external A B C D 7 Quick Reference Setting Dip Switches Figure 7A DipSwitches Dip switch settings POSITION Feature Explanation Dip switc...

Страница 11: ...s must be min 300V rating Sup Com Ret I Com Os V Boil Boil Dem Dem tN4 Fuse Transformer 1 VA 115 V 18 V 100 H 6 A inductor Pot 0 1 F 250V R Class 2 only Off On A B C D 1008 02 599395 May 2006 12345 Ma...

Страница 12: ...te and sup porting installation data Unless otherwise provided the distributor or dealer will contact the GRUNDFOS factory or authorized service station for instructions Any defective product to be re...

Отзывы: