Operating modes

The pumps are designed for intermittent operation 
(S3). When completely submerged, the pumps can 
also operate continuously (S1).
S3, intermittent operation:
Operating mode S3 means that within 10 minutes the 
pump must be in operation for 4 minutes and 
stopped for 6 minutes.

Fig. 11

S3, intermittent operation

S1, continuous operation:
In this operating mode, the pump can operate 
continuously without being stopped for cooling. 

Fig. 12

S1, continuous operation

Servicing the product

Stop the pump 
immediately in the 
following cases:
• abnormal noise
• abnormal vibrations
• power supply failure
• water supply failure
• other pump failure.
Do not restart the pump 
until the cause of the 
faults have been 
identified and removed.

TM0

4

 4

52

7 1

5

0

9

TM

04

 45

2

8

 15

09

Operation

Stop

6 min.

4 min.

10 min.

P

t

P

t

Operation

Stop

Compliance with the standards EN 
60079-17 and EN 60079-19 is a customer 
responsibility.

CAUTION
Sharp element

Minor or moderate 
personal injury
- Wear protective gloves 

when touching the 
impeller.

All regulations applying to pumps installed 
in potentially explosive environments must 
be observed.
Make sure that no work is carried out in 
potentially explosive atmosphere.

Before beginning installation procedures, 
make sure that the atmosphere in the tank 
is not potentially explosive.

CAUTION
Body injury

Minor or moderate 
personal injury
- Always support the 

pump by lifting chains 
or place it in horizontal 
position to secure 
stability. During 
maintenance and 
service, including 
transport to service 
workshop, always 
support the pump.

Содержание SL1 Series

Страница 1: ...SL1 SLV 1 1 11 kW 50 60 Hz DIN Safety instructions GRUNDFOS INSTRUCTIONS Installation and operating instructions in other languages for 50 60 Hz net grundfos com qr i 96771279...

Страница 2: ...installation and operating instructions Keep these safety instructions at the installation site for future reference Read this document before installing the product Installation and operation must co...

Страница 3: ...e liquids large quantities of drainage and surface water domestic wastewater with discharge from toilets wastewater with a high content of fibres SuperVortex impeller municipal and commercial sewage a...

Страница 4: ...e from 0 40 C TM07 5414 3919 Pos Description 1 Approvals 2 Explosion protection certificate No 3 Ex description 4 Type designation 5 Model number 6 Production code year and week 7 Enclosure class to I...

Страница 5: ...f version 2 Number of poles 2 pole 4 4 pole 50 60 Frequency Hz 50 Hz 60 Hz 0B Voltage and starting method 3 x 400 415 V direct on line connection 0D 3 x 380 415 V direct on line connection 1D 3 x 380...

Страница 6: ...eb mb IIB T3 T4 Gb with WIO sensor Transporting the product Handling and lifting the product Fig 3 Lifting bracket Direct drive pump without sensor CE 0344 II 2 G Ex db h IIB T4 Gb Direct drive pump w...

Страница 7: ...ng the pump Carelessness during lifting or transport may cause injury to persons or damage to the pump WARNING Electric shock Death or serious personal injury Connect the pump to an external main swit...

Страница 8: ...n the stator windings has a nominal switch temperature of 150 C and must guarantee the disconnection of the power supply The power supply must be reset manually 8 The control unit must protect the WIO...

Страница 9: ...rushing of hands Death or serious personal injury Do not put your hands or any tool into the pump inlet or outlet port after the pump is connected to the power supply unless the pump has been switched...

Страница 10: ...he atmosphere in the tank is not potentially explosive Inspect the oil level and condition every 3000 operating hours or at least once a year When the pump is new or after replacement of the shaft sea...

Страница 11: ...sion proof pumps make sure that an external earth conductor is connected to the external earth terminal on the pump using a secure cable clamp Clean the surface of the external earth connection and mo...

Страница 12: ...2 WARNING Electric shock Death or serious personal injury Make sure the earth and phase conductors are not mixed up Make sure the earth conductor is connected first Make sure that the product is earth...

Страница 13: ...e cable DOL TM04 6884 0314 Standard version Thermal switch and moisture switch Sensor version Thermal switch Pt1000 resistor moisture switch and water in oil sensor Sensor version Thermal switch PTC t...

Страница 14: ...switch and moisture switch Sensor version Thermal switch Pt1000 resistor moisture switch and water in oil sensor Sensor version Thermal switch PTC thermistor moisture switch and water in oil sensor 4...

Страница 15: ...d version Thermal switch and moisture switch Sensor version Thermal switch Pt1000 resistor moisture switch and water in oil sensor Sensor version Thermal switch PTC thermistor moisture switch and wate...

Страница 16: ...rd version Thermal switch and moisture switch Sensor version Thermal switch Pt1000 resistor moisture switch and water in oil sensor Sensor version Thermal switch PTC thermistor moisture switch and wat...

Страница 17: ...break the circuit at 150 C The maximum operating current of the thermal switch is 0 5 A at 500 VAC and cos 0 6 The switch must be able to break a coil in the supply circuit Pumps with WIO sensor Pumps...

Страница 18: ...ta sheet for the frequency converter used Use screened power cable if there is a risk that electrical noise can disturb other electrical equipment See data sheet for the frequency converter used CAUTI...

Страница 19: ...onverter Frequency converter use can increase the wear on the shaft seal and bearings The noise level may increase See the installation and operating instructions for the frequency converter used The...

Страница 20: ...l the cause of the faults have been identified and removed TM04 4527 1509 TM04 4528 1509 Operation Stop 6 min 4 min 10 min P t P t Operation Stop Compliance with the standards EN 60079 17 and EN 60079...

Страница 21: ...ke sure that all rotating parts have stopped moving Maintenance work on explosion proof pumps must be carried out by Grundfos or an authorised service workshop This applies to both electric and hydrau...

Страница 22: ...ard Minor or moderate personal injury Make sure that the lifting bracket is tightened before lifting the pump Always lift the pump by its lifting bracket or by a forklift truck if the pump is fixed on...

Страница 23: ...pump must be switched off before working on the pump DANGER Crushing of hands Death or serious personal injury Before diagnosing any fault make sure that the fuses have been removed or the main switc...

Страница 24: ...esclusiva responsabilit che i prodotti SL1 SLV ai quale si riferisce questa dichiarazione sono conformi alle seguenti direttive del Consiglio riguardanti il riavvicinamento delle legislazioni degli S...

Страница 25: ...41 2003 except clause 25 8 A1 2004 A2 2010 EMC Directive 2014 30 EU For sensor versions the following standards are used EN 61326 1 2013 RoHS Directives 2011 65 EU and 2015 863 EU Standard used EN IEC...

Страница 26: ...d clarons sous notre seule responsabilit que les produits auxquels se r f re cette d claration sont conformes aux lois ordonnances normes et sp cifications marocaines pour les quelles la conformit es...

Страница 27: ...27 3 Zh 6 6 9 6 6 9 6 6 9 6 6 9...

Страница 28: ...28 6 6 9 6 6 9 ZD 6 6 9 1 2 3 6 6 9 004 2011 010 2011 020 2011 D http net grundfos com qr i 98947334...

Страница 29: ...of the construction product as set out in Annex V System 3 7 In case of the declaration of performance concerning a construction product covered by a harmonised standard T V Rheinland LGA Products Gmb...

Страница 30: ...hla ovan mi vlastnostmi v bod 9 DE EU Leistungserkl rung gem Anhang III der Verordnung EU Nr 305 2011 Bauprodukte Verordnung 1 Einmalige Kennnummer des Produkttyps EN 12050 1 oder EN 12050 2 SL1 50 2...

Страница 31: ...i f lgende Anvendte standarder EN 12050 1 2001 eller EN 12050 2 2000 SL1 50 10 Ydeevnen for den byggevare der er anf rt i punkt 1 og 2 er i overensstemmelse med den deklarerede ydeevne i punkt 9 EE EU...

Страница 32: ...eclaraci n de prestaciones satisfacen las caracter sticas fundamentales y requisitos en materia de prestaciones descritos en Normas aplicadas EN 12050 1 2001 o EN 12050 2 2000 SL1 50 10 Las prestacion...

Страница 33: ...u produit de construction comme stipul dans l Annexe V Syst me 3 7 En cas de d claration des performances d un produit de construction couvert par une norme harmonis e T V Rheinland LGA Products GmbH...

Страница 34: ...ladu je s izjavljenom izvedbom u to ki 9 HU EU teljes tm nynyilatkozat a 305 2011 sz m EU rendelet III mell klet nek megfelel en p t si term k rendelet 1 A term kt pus egyedi azonos t k dja EN 12050 1...

Страница 35: ...pplicate EN 12050 1 2001 oppure EN 12050 2 2000 SL1 50 10 Le prestazioni del prodotto identificato ai punti 1 e 2 sono conformi alle prestazioni dichiarate al punto 9 LT EB eksploatacini savybi deklar...

Страница 36: ...s pa bas atbilst 9 punkt nor d taj m deklar taj m ekspluat cijas pa b m NL Prestatieverklaring van EU in overeenstemming met Bijlage III van verordening EU nr 305 2011 Bouwproductenverordening 1 Uniek...

Страница 37: ...10 W a ciwo ci u ytkowe wyrobu okre lone w pkt 1 i 2 s zgodne z w a ciwo ciami u ytkowymi deklarowanymi w pkt 9 PT Declara o de desempenho UE em conformidade com o Anexo III do Regulamento UE N 305 2...

Страница 38: ...50 2 2000 SL1 50 10 Performan a produsului identificat la punctele 1 i 2 este n conformitate cu performan a declarat la punctul 9 RS EU deklaracija o performansama u skladu sa Aneksom III propisa EU b...

Страница 39: ...med EN 12050 1 p typskylten SL1 50 pumpar f r pumpning av fekaliefritt avloppsvatten m rkta med EN 12050 2 p typskylten 4 Tillverkarens namn registrerade f retagsnamn eller registrerade varum rke samt...

Страница 40: ...00 SL1 50 10 Delovanje proizvoda identificiranega pod to kama 1 in 2 je skladno z deklariranim delovanjem pod to ko 9 SK Vyhl senie o parametroch EU v s lade s pr lohou III nariadenia E 305 2011 Naria...

Страница 41: ...s na y nelik sistem veya sistemler Sistem 3 7 Uyumlu bir standart kapsam ndaki bir in aat r n yle ilgili performans beyan durumunda T V Rheinland LGA Products GmbH tan mlama numaras 0197 EN 12050 1 ve...

Страница 42: ...med EN 12050 1 p navneplaten Pumper for pumping av avl psvann uten avf ring merket med EN 12050 2 p navneplaten 4 Navn registrert handelsnavn eller registrert varemerke og kontaktadresse for produsen...

Страница 43: ...i m t ti u chu n h i h a T V Rheinland LGA Products GmbH s nh n di n 0197 Th c hi n ki m tra theo ti u chu n EN 12050 1 ho c EN 12050 2 SL1 50 theo h th ng 3 m t nh ng nhi m v c a b n th ba nh quy nh...

Страница 44: ...50 51 51 E mail info_GDK grundfos com www grundfos com DK Estonia GRUNDFOS Pumps Eesti O Peterburi tee 92G 11415 Tallinn Tel 372 606 1690 Fax 372 606 1691 Finland OY GRUNDFOS Pumput AB Trukkikuja 1 F...

Страница 45: ...ozsk 4D 821 09 BRATISLAVA Phona 421 2 5020 1426 sk grundfos com Slovenia GRUNDFOS LJUBLJANA d o o Lesko kova 9e 1122 Ljubljana Phone 386 0 1 568 06 10 Telefax 386 0 1 568 06 19 E mail tehnika si grund...

Страница 46: ...9151 Trademarks displayed in this material including but not limited to Grundfos the Grundfos logo and be think innovate are registered trademarks owned by The Grundfos Group All rights reserved 2021...

Отзывы: