English (GB)
5
Lifting points (top)
Use the right lifting point to keep the pump balanced. S pumps
are equipped with a lifting bracket with lifting points ensuring that
the pump can be lifted in a safe manner. See fig.
and table
below for the correct lifting points.
Fig. 2
Lifting points for installation types S, C and D*
* The design of the lifting bracket may be different from the one
in the drawing. It does not affect the handling of the product,
however.
TM0
4
717
3
1
7
1
0
Range 50 and
Range 58, 62, 66 and
Front
Middle
Nose
Front
Middle
Outlet flange
size
Pump range
50
54
58
62
66
70
DN 80
Middle
Middle
-
-
-
-
DN 100
Middle
Middle
-
-
-
-
DN 125
Middle
Middle
Middle
Middle
-
-
DN 200
Front
Front
Front
Middle
Middle
Middle
DN 250
-
Front
-
-
Middle
Middle
DN 300
-
-
Front
Middle
Middle
Middle
DN 500
-
-
-
-
Nose
Front
DN 600
-
-
-
-
Nose
Front
Always lift installation type ST
pumps in the middle lifting point
to make sure the pump is in