7.4 SM 113, optional
SM 113 is designed and used for the collection and transfer of
additional sensor data. SM 113 works together with IO 113 with
communication module, product number 98097390, as shown in
the figure below.
Fig. 29
IO 113 and SM 113
SM 113 can collect data from these devices:
• current sensors, 4-20 mA*
• Pt100** thermal sensors.
* Vibration sensor (FPV)
** Maximum three Pt100 sensors.
7.5 Switches and sensors
Install an additional level switch to ensure that the pump is
stopped in case the primary stop level switch is not operating.
A pump includes the following switches and sensors:
• three thermal switches or three thermal protectors in the stator
windings
• moisture switches:
– in range 50-70: one under the motor top cover
– in Ex pumps, range 50-58 and 70: one under the motor top
cover and one in the stator housing
– in Ex pump, range 62: two under the motor top cover.
• one optional Pt100 sensor in the bearing or in the stator
winding
• one analog and optional WIO sensor in the oil chamber.
Fig. 30
Sensor cable seen towards the pump
Fig. 31
Sensor connections, SM 113 outside motor
Legend to fig.
TM
05
196
6
41
11
-
TM
03
40
83
16
06
Do not let the pump run dry.
TM
03
28
02
48
05
PE
T1 T2
G1 A1 G2 A2 K1 K2 R1 R2
D1 D2 D3 D4 D5 D6 D7 D8
P1 P2 P3 P4 P5
A Y B
I1 I2 I3
ON
DIP
1 2 3 4 5 6 7 8 9 10 11 12
1 2 3 4 5 6 7 8 9 10 11 1213 14
Power line
communicati
on using
Grundfos
GENIbus
IO 113
SM 113
Sensor inputs
1
2
3
4
5
6
7
8
9
Yellow and green
TM
04
60
67
48
09
Symbo
l
Description
T
Thermal switch
M
Moisture switch
P
Power input
S
Sensor input
SM 113 Sensor board
IO 113
IO 113 with internal alarm relay
(250 VAC)
"db"
Flameproof enclosure
"mb"
Protection according to EN 60079-
0:2012 + A11:2013,
EN 60079-18:2015 + A1:2017
and
IEC 60079-0:2011,
IEC 60079-18:2017
"eb"
Protection according to EN 60079-
0:2012 + A11:2013,
EN 60079-7:2015 + A1:2017,
and
IEC 60079-0:2011,
IEC 60079-7:2017
IO 113
SM 113
S
Analog and
digital outputs
P
L3
L
L
Power
side
Signal
side
WIO
"eb" and "mb"
"db"